Plan Review Details - Permit 15040957
Plan Review Stops For Permit 15040957
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2015-07-21 Cont ID  
Sent By jgomez Date 2015-07-21 Time 17:44 Rev Time 0.00
Received By jgomez Date 2015-07-21 Time 17:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status   Date 2015-07-14 Cont ID  
Sent By jgomez Date 2015-07-14 Time 07:58 Rev Time 0.00
Received By jgomez Date 2015-07-14 Time 07:49 Sent To  
Notes
2015-07-14 08:08:55RESPONDED TO MRS. MICKEY'S E-MAIL BELOW. THE 12/31/2015
 EXPIRATION DATE IS FOR THE "QUALITY ASSURANCE CONTRACT"
 NOT THE PRODUCT APPROVAL.
  
  
 THANK YOU FOR YOUR REPLY. PLEASE NOTE THE FOLLOWING:
  
 YOUR COMMENT:
  
 B) THE USP PRODUCT APPROVAL FL859-R4 IS FOR THE 2007
 CODE VERSION.? THIS
  
 ONE CANNOT BE USED.?? THE CODE VERSION IS TOO OLD.???
 THE CODE FOR WHICH
  
 THIS HOUSE WAS REVIEWED WAS FOR 2010 FBC.???? NEED
 PRODUCT APPROVAL FOR THE
  
 2010 FBC CODE VERSION.
  
 ?
  
 THIS CODE STOPS AT 2007. PLEASE SEE BELOW. THE ATTACHED
 PA DOES NOT EXPIRE TILL 12.31.15.
  
 ?
  
 IF YOU CAN DIRECT ME TO THE 2010 FBC VERSION, I WOULD
 APPRECIATE IT.
  
 ?
  
 I WILL EMAIL YOU TOMORROW WITH THE ENGINEER ON RECORD
 APPROVAL FOR THE OTHER PA AND WILL HAVE THE REVISED
 ENERGY CALCS EMAILED TO YOU TOMORROW FOR YOUR REVIEW.
  
 ?
  
 THANK YOU
  
 ?
  
 MICKEY

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-07-13 Cont ID  
Sent By jgomez Date 2015-07-13 Time 14:14 Rev Time 0.00
Received By jgomez Date 2015-07-13 Time 14:14 Sent To  
Notes
2015-07-13 14:28:38BUILDING REVIEW COMMENTS FOR E-MAILED INFORMATION SENT
 BY MRS. MICKEY RUDICK:
  
 1- USP PRODUCT APPROVALS SUBMITTED:
 A) THE USP PRODUCT APPROVAL FL6223-R3 IS FOR THE 2014
 FBC AND IS PENDING APPROVAL. THIS ONE CAN NOT BE USED
 BECAUSE IS NOT APPROVED YET AND IS FOR A DIFFERENT CODE
 VERSION. THE CODE FOR WHICH THIS HOUSE WAS REVIEWED WAS
 FOR 2010 FBC. NEED PRODUCT APPROVAL FOR THE 2010 FBC
 CODE VERSION.
  
 B) THE USP PRODUCT APPROVAL FL859-R4 IS FOR THE 2007
 CODE VERSION. THIS ONE CAN NOT BE USED. THE CODE
 VERSION IS TOO OLD. THE CODE FOR WHICH THIS HOUSE WAS
 REVIEWED WAS FOR 2010 FBC. NEED PRODUCT APPROVAL FOR
 THE 2010 FBC CODE VERSION.
  
 C) THE USP PRODUCT APPROVAL FL6223-R1 IS FOR THE 2007
 CODE VERSION. THIS ONE CAN NOT BE USED. THE CODE
 VERSION IS TOO OLD. THE CODE FOR WHICH THIS HOUSE WAS
 REVIEWED WAS FOR 2010 FBC. NEED PRODUCT APPROVAL FOR
 THE 2010 FBC CODE VERSION.
  
 2- THE PRECAST LINTELS NOA 14-0903.02 SUBMITTED IS OK.
  
 3- SLIDING GLASS DOORS NOA 14-0128.11 SUBMITTED IS OK.
  
  
 BELOW ARE THE COMMENTS THAT MR. ROBERT IS GOING TO TAKE
 CARE OF:
  
 2- ENERGY CALCULATIONS SUBMITTED:
 A) ITEM # 5 STATES THAT CALCULATIONS ARE NOT DONE WORST
 CASE SCENARIO. THEN, WHY THE BUILDING WAS ROTATED 90
 DEGREES AS SPECIFIED ON PAGE 2 OF 6. ALSO WINDOWS AND
 WALLS ON PAGE 3 OF 6 SHOW ROTATED BUILDING ORIENTATION.
 PROVIDE CALCULATIONS THAT SHOW THE ACTUAL ORIENTATION
 OF THE BUILDING. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION. (REPEAT COMMENT. THE ENERGY CALCULATIONS
 NEED TO BE DONE FOR THE ACTUAL ORIENTATION OF THE
 BUILDING. ACCORDING TO THE NORTH ARROW SHOWN ON THE
 SURVEY, THERE ARE NOT NORTH-EAST, EAST-SOUTH,
 SOUTH-WEST, WEST-NORTH, ETC. . REVISE PLANS SHOWING THE
 ACTUAL ORIENTATION NORTH, SOUTH, EAST AND WEST).
  
 B) DOORS ON PAGE 3 OF 6 SPECIFY WOOD DOOR. WHERE IS THE
 WOOD DOOR?. WHY IN BEDROOMS?. SEC. 103.2.2 OF 2010
 FBC-ENERGY CONSERVATION. (REPEAT COMMENT. THE BEDROOM
 SPECIFICATION WAS CHANGED BY HAND TO SAY "GARAGE TO
 HOUSE". HAND CHANGES ARE NOT ALLOWED ON A COMPUTER
 GENERATED PROGRAM. GARAGE NOTES ON SHEET C-1 HAVE THE
 OPTION FOR 3 TYPES OF DOORS, SO SOLID WOOD DOOR MAY NOT
 BE INSTALLED. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION. REVISE AS REQUIRED TO MATCH).
  
 IMPORTANT: LABELS SHOWING THE U-FACTOR AND SHGC FACTOR
 SPECIFIED ON ITEM #7 FOR WINDOWS AND DOORS WILL BE
 VERIFIED IN FIELD.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 *** PLEASE REPLACE AND REMOVED ANY REVISED DRAWING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-07-10 Cont ID  
Sent By jgomez Date 2015-07-10 Time 15:38 Rev Time 0.00
Received By jgomez Date 2015-07-10 Time 15:38 Sent To  
Notes
2015-07-10 15:38:43BUILDING REVIEW COMMENTS;
  
 ****NOTE: BUILDING REVIEW MAY BE APPROVED WITH PROVISO.
 THE PERMIT MAY BE ISSUED AND THESE COMMENTS MAY BE
 ADDRESSED AS "REVISIONS" AFTER THE PERMIT IS ISSUED.
 FEES MAY APPLY. PLEASE ADVICE IF YOU WANT THE PROVISO
 OPTION.
  
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) USP STRUCTURAL CONNECTORS SPECIFIED ON PLANS AND ALL
 DETAILS. (FLORIDA PRODUCT APPROVALS FL6223-R1 AND FL
 859-R4 SUBMITTED ARE FOR 2007 FBC. NEED PRODUCT
 APPROVALS FOR CURRENT 2010 FBC, WHICH IS THE CODE
 ADOPTED FOR THIS PERMIT APPLICATION).
  
 B) ALL PRECAST LINTELS SPECIFIED ON PLANS. (NOA
 13-0321.07 SUBMITTED IS FOR 4", 6" AND 12" PRECAST
 LINTELS. THESE LINTELS ARE NOT SPECIFIED ON PLANS.
 PROVIDE CORRECT PRODUCT APPROVAL THAT MATCHES LINTELS
 SPECIFIED ON PLANS).
  
 C) NEW COMMENT: SLIDING GLASS DOORS A SHOWN ON PLANS.
 NEW NOA 15-0106.08 SUBMITTED DOESN'T COVER SIZES SHOWN
 ON PLANS. PLANS CALL FOR 10'-0" HIGH DOORS. (NOA
 14-0128.11 SUBMITTED THE FIRS TIME WAS OK.)
  
 2- ENERGY CALCULATIONS SUBMITTED:
 A) ITEM # 5 STATES THAT CALCULATIONS ARE NOT DONE WORST
 CASE SCENARIO. THEN, WHY THE BUILDING WAS ROTATED 90
 DEGREES AS SPECIFIED ON PAGE 2 OF 6. ALSO WINDOWS AND
 WALLS ON PAGE 3 OF 6 SHOW ROTATED BUILDING ORIENTATION.
 PROVIDE CALCULATIONS THAT SHOW THE ACTUAL ORIENTATION
 OF THE BUILDING. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION. (REPEAT COMMENT. THE ENERGY CALCULATIONS
 NEED TO BE DONE FOR THE ACTUAL ORIENTATION OF THE
 BUILDING. ACCORDING TO THE NORTH ARROW SHOWN ON THE
 SURVEY, THERE ARE NOT NORTH-EAST, EAST-SOUTH,
 SOUTH-WEST, WEST-NORTH, ETC. . REVISE PLANS SHOWING THE
 ACTUAL ORIENTATION NORTH, SOUTH, EAST AND WEST).
  
 B) DOORS ON PAGE 3 OF 6 SPECIFY WOOD DOOR. WHERE IS THE
 WOOD DOOR?. WHY IN BEDROOMS?. SEC. 103.2.2 OF 2010
 FBC-ENERGY CONSERVATION. (REPEAT COMMENT. THE BEDROOM
 SPECIFICATION WAS CHANGED BY HAND TO SAY "GARAGE TO
 HOUSE". HAND CHANGES ARE NOT ALLOWED ON A COMPUTER
 GENERATED PROGRAM. GARAGE NOTES ON SHEET C-1 HAVE THE
 OPTION FOR 3 TYPES OF DOORS, SO SOLID WOOD DOOR MAY NOT
 BE INSTALLED. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION. REVISE AS REQUIRED TO MATCH).
  
 IMPORTANT: LABELS SHOWING THE U-FACTOR AND SHGC FACTOR
 SPECIFIED ON ITEM #7 FOR WINDOWS AND DOORS WILL BE
 VERIFIED IN FIELD.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 *** PLEASE REPLACE AND REMOVED ANY REVISED DRAWING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-06-11 Cont ID  
Sent By jgomez Date 2015-06-11 Time 09:05 Rev Time 0.00
Received By jgomez Date 2015-06-11 Time 07:54 Sent To  
Notes
2015-06-11 09:16:19NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- VALUATION DECLARED IN THE PERMIT APPLICATION WAS
 UPDATED TO $517,735. VALUATION TO INCLUDE ALL LABOR,
 MATERIALS, CONTRACTOR'S OVERHEAD AND PROFIT AND ALL
 DESIGN PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. THE PERMIT FEE BALANCE IS $8,484.60.
  
 2- PLEASE PROVIDE COPY OF THE IMPACT FEES PAID RECEIPT.
 COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT ARE
 ALWAYS REQUIRED BY PALM BEACH COUNTY.
  
 3- ENGINEER OF RECORD TO SPECIFY ROOF TILE FASTENING AS
 REQUIRED BY SEC. 107.2.1.2 CITY AMENDMENTS. IF
 SPECIFYING ADHESIVE, THEN PROVIDE PRODUCT APPROVAL. IF
 SPECIFYING SCREWS, THEN SPECIFY THE SIZE AND NUMBER OF
 SCREWS.
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ALL USP STRUCTURAL CONNECTORS SPECIFIED ON PLANS AND
 ALL DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR.
 OR, LIST THE FLORIDA PRODUCT APPROVAL NUMBER NEXT TO
 EACH SPECIFIED CONNECTOR.
  
 B) ALL PRECAST LINTELS SPECIFIED ON PLANS.
  
 C) ROOF TILE ADHESIVE IF SPECIFIED BY THE ENGINEER OF
 RECORD. SEE ROOF TILE PRODUCT APPROVAL FOR LISTED
 PRODUCTS.
  
 D) THERE WERE TWO ROOF TILE PRODUCT APPROVALS
 SUBMITTED. NOA 11-0321.03 AND FLORIDA PRODUCT APPROVAL
 FL7473-R5 ALONG WITH RIDGE FL PRODUCT APPROVAL
 FL8095-R2. PROVIDE COMPLETE ROOFING PACKAGE EITHER
 MIAMI NOA'S OR COMPLETE PACKAGE FROM FLORIDA PRODUCT
 APPROVAL. MISMATCHING IS NOT ALLOWED.
  
 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1
 CITY AMENDMENTS. NOTE: PRODUCT APPROVALS SUBMITTED
 DON'T IDENTIFY WHO REVIEWED THEM. THERE IS ONLY A
 STATEMENT SAYING REVIEWED WITH SOME INITIALS AND DATE.
 BUT, THIS DOESN'T IDENTIFY THE REVIEWER OF RECORD.
 PROVIDE NAME OF THE ENGINEER WHO APPROVED IT. ENGINEER
 MAY ALSO PROVIDE LETTER IDENTIFYING EACH PRODUCT
 APPROVAL THAT WAS REVIEWED AND APPROVED.
  
 6- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION AND INSTALLATION OF SOFFITS AND CEILINGS
 IN COVERED PORCHES SHOWING COMPLIANCE WITH SEC. R703.2
 OF 2010 FBC-RESIDENTIAL. NOTE: TYP. WALL SECTION ONLY
 SPECIFIES STUCCO ON METHAL LATH. WILL THIS RESIST THE
 DESIGN PRESSURES OF SEC. R301 OF 2010 FBC-RESIDENTIAL?.
  
 7- CLEARLY SPECIFY SIZE OF MULLIONS TO BE USED AT ENTRY
 DOOR ASSEMBLY AND ALL OTHER WINDOW MULLIONS TO VERIFY
 COMPLIANCE WITH THE PRODUCT APPROVAL SUBMITTED AND
 CALCULATED DESIGN PRESSURES. SEC. R301.1 OF 2010
 FBC-RESIDENTIAL.
  
 8- SURVEYOR NOTE #6 STATES THAT THIS SURVEY IS NOT
 INTENDED FOR CONSTRUCTION PURPOSES. PROVIDE SURVEY THAT
 MAY BE USED FOR CONSTRUCTION. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 9-ENERGY CALCULATIONS SUBMITTED:
 A) ITEM # 5 STATES THAT CALCULATIONS ARE NOT DONE WORST
 CASE SCENARIO. THEN, CLARIFY WHY THE BUILDING WAS
 ROTATED 90 DEGREES AS SPECIFIED ON PAGE 2 OF 6. ALSO
 WINDOWS AND WALLS ON PAGE 3 OF 6 SHOW ROTATED BUILDING
 ORIENTATION. PROVIDE CALCULATIONS THAT SHOW THE ACTUAL
 ORIENTATION OF THE BUILDING. SEC. 103.2.2 OF 2010
 FBC-ENERGY CONSERVATION.
  
 B) ITEM #10 CALLS FOR R-38 CEILING INSULATION. THIS
 DOESN'T MATCH PLANS. REVISE AS REQUIRED EITHER PLANS OR
 CALCULATIONS TO MATCH. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 C) DOORS ON PAGE 3 OF 6 SPECIFY WOOD DOOR. WHERE IS THE
 WOOD DOOR?. WHY IN BEDROOMS?. THERE ARE NOT SOLID WOOD
 DOORS ON EXTERIOR DOORS. SEE PRODUCT APPROVALS. SEC.
 103.2.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 D) SEE ADDITIONAL COMMENTS BY THE MECHANICAL REVIEWER.
  
 IMPORTANT: THE U-FACTOR AND SHGC FACTOR SPECIFIED ON
 ITEM #7 FOR WINDOWS AND DOORS WILL BE VERIFIED IN
 FIELD.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 *** PLEASE REPLACE AND REMOVED ANY REVISED DRAWING.
 SUBMIT ASIDE ORIGINAL SET OF DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-07-10 Cont ID  
Sent By albarran Date 2015-07-10 Time 12:18 Rev Time 0.00
Received By albarran Date 2015-07-10 Time 11:58 Sent To B
Notes
2015-07-10 12:19:19ALL COMMENTS HAVE BEEN SATISFACTORILY ADDRESSED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-06-01 Cont ID  
Sent By albarran Date 2015-06-01 Time 19:14 Rev Time 0.00
Received By albarran Date 2015-06-01 Time 18:32 Sent To  
Notes
2015-06-01 19:15:23THE FOLLOWING ITEMS SHALL BE CORRECTED AND THE PLANS
 RESUBMITTED FOR A SECOND REVIEW:
  
 THESE PLANS WERE REVIEWED FOR COMPLIANCE WITH THE 2008
 EDITION OF THE NEC, THE 2013 EDITION OF THE NFPA72, THE
 APPLICABLE CHAPTERS OF THE 2010 EDITION OF THE FLORIDA
 BUILDING CODE, FLORIDA BUILDING CODE RESIDENTIAL AND
 FLORIDA BUILDING CODE ENERGY CONSERVATION.
 1. THE SERVICE RISER INDICATES THHN CONDUCTORS TO POOL
 PANEL. PER NEC 300.5(B), IF THESE OR ANY OTHER, WILL
 TRAVEL UNDERGROUND THEY SHALL HAVE AN INSULATION LISTED
 FOR WET LOCATION
 2. ARC-FAULT PROTECTION SHALL BE AS INDICATED IN THE
 CURRENTLY APPLICABLE CODE. 2008 EDITION OF NEC
 3. NOT JUST THOSE BOXES MARKED AS FB, BUT ALL CEILING
 BOXES USED FOR LIGHTING SHALL BE LISTED TO SUPPORT
 50#?S AS INDICATED IN NEC 314.27(A)
 4. EVERY RECEPTACLE O THE EXTERIOR/IN A WET LOCATION
 SHALL BE LISTED AS WEATHER-RESISTANT AS INDICATED IN
 NEC 406.8(B)
 5. NOWHERE ON THE DRAWINGS DID I SEE A NOTE FOR THE
 BONDING OF THE GAS LINE AS INDICATED IN NEC 250.104(B)
  
 AS INDICATED ABOVE, THIS INSTALLATION SHALL COMPLY WITH
 ALL THE ENERGY CONSERVATION REQUIREMENTS OF THE 2010
 FBC-ENERGY CONSERVATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS
  
 FOR QUESTIONS ON THE ABOVE, PLEASE CONTACT:
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 PH: (561) 805-6743
 EMAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-07-21 Cont ID  
Sent By jgomez Date 2015-07-21 Time 17:43 Rev Time 0.00
Received By jgomez Date 2015-07-16 Time 13:39 Sent To  
Notes
2015-07-16 13:40:34ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-07-10 Cont ID  
Sent By jgomez Date 2015-07-10 Time 19:45 Rev Time 0.00
Received By jgomez Date 2015-06-30 Time 08:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-06-11 Cont ID  
Sent By jgomez Date 2015-06-11 Time 12:49 Rev Time  
Received By jgomez Date 2015-04-24 Time   Sent To  
Notes
2015-04-25 12:35:29R11

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2015-07-10 Cont ID  
Sent By jgomez Date 2015-07-10 Time 15:52 Rev Time 0.00
Received By jgomez Date 2015-07-10 Time 15:52 Sent To  
Notes
2015-07-10 15:53:12$9,904.34 PAID. MU-2015-8885.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-06-11 Cont ID  
Sent By jgomez Date 2015-06-11 Time 12:49 Rev Time 0.00
Received By jgomez Date 2015-06-11 Time 12:49 Sent To  
Notes
2015-06-11 12:49:31PROVIDE COPY OF THE IMPACT FEES PAID RECEIPT.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-07-17 Cont ID  
Sent By ccole Date 2015-07-17 Time 07:10 Rev Time 0.00
Received By ccole Date 2015-07-17 Time 06:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-07-10 Cont ID  
Sent By ccole Date 2015-07-10 Time 08:46 Rev Time 0.00
Received By ccole Date 2015-07-10 Time 08:46 Sent To  
Notes
2015-07-10 08:51:352ND REVIEW: FBC 20140 MECHANICAL
 PERMIT #15040957 7/10/15
  
 1) THE NORTH ARROW DIRECTION ON THE REVISED AC PLAN
 DOES NOT MATCH THE NORTH ARROW DIRECTION ON THE NEW
 SURVEY: PLEASE CORRECT.
 2) BASED ON THE NORTH DIRECTIONAL ARROW SHOWN ON THE
 NEW SURVEY (WHICH APPEARS CORRECT BY PAPA MAPPING), THE
 WINDOW DIRECTIONAL ORIENTATIONS ON THE AC SIZING
 CALCULATIONS ARE INCORRECT: PLEASE REVISE THE
 CALCULATIONS.
 3) THE AC PLAN NOTES INDICATES THE CONDENSATE PIPES
 WILL BE RUN THROUGH THE ATTIC, HOWEVER THE NOTES ALSO
 INDICATE THE AHU'S WILL BE HUNG FROM THE GARAGE
 CEILING. WILL A CONDENSATE PUMP BE INSTALLED?
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-06-04 Cont ID  
Sent By ccole Date 2015-06-04 Time 11:00 Rev Time 0.00
Received By ccole Date 2015-06-04 Time 08:07 Sent To  
Notes
2015-06-04 08:46:061ST REVIEW: FBC 2010 RESIDENTIAL & MECHANICAL
  
 1) THE NUMBER OF WINDOWS AND DOORS LISTED IN THE ENERGY
 CALCULATIONS AND THE MANUAL J SIZING CALCS DO NOT MATCH
 THE HOUSE PLANS. SEE SHEET A-1: I AM COUNTING 15
 WINDOWS- EITHER SH OR FIXED GLASS, 2 TRIPLE SGD'S, 2
 SIDE-HINGED DOUBLE DOORS, AND 1 SINGLE SIDE HINGED
 DOORS. THE CALCS ARE LISTING ONLY 14 WINDOWS AND 1 SIDE
 HINGED DOOR.
 PLEASE REVISE THE CALCS AND THE AC PLANS: PLACE A NORTH
 ARROW ON THE AC PLANS AND NUMBER THE WINDOWS AND DOORS
 TO CORRELATE WITH THE CORRECTED CALCULATION SUBMITTALS.
 PLEASE NOTE THE MANUAL J IS INDICATING R38 INSULATION
 ABOVE THE CEILING, HOWEVER THE PLANS ARE INDICATING
 R30.
 2) ENERGY FORM 405-2010: COMPLETE THE CODE COMPLIANCE
 CHECKLIST ON PAGE 6 OF THE CORRECTED SUBMITTAL.
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE WATER
 HEATER AND VENT, AND THE KITCHEN HOOD AND MAKE-UP AIR
 COMPONENTS.
 PLEASE NOTE THE IGNITION SOURCE OF THE WATER HEATER
 SHALL NOT BE LESS THAN 18" ABOVE THE GARAGE FLOOR,
 UNLESS LISTED AS FLAMMABLE VAPOR IGNITION RESISTANT-
 SECTION G2408.2 FBC-10 RES.
 4) THE AC PLAN APPEARS TO INDICATE FLEX DUCTS IN THE
 GARAGE WHICH ARE PROHIBITED PER SECTION R302.5.2
 RESIDENTIAL. UNLESS THE AIR HANDLERS ARE IN THE ATTIC,
 STEEL DUCTS OR DUCT BOARD MUST BE INSTALLED.
 5) SUBMIT TWO COPIES OF THE FL. PRODUCT APPROVAL FOR
 THE BMP CONDENSER TIE-DOWN CLIPS.
  
 CHRISTOPHER COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-07-10 Cont ID  
Sent By tklarge Date 2015-07-10 Time 04:49 Rev Time 0.00
Received By tklarge Date 2015-07-10 Time 04:25 Sent To  
Notes
2015-07-10 04:49:59SEPARATE PERMIT REQD. FOR GAS.
 GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS AND GAS RISER THAT REFLECTS THE
 ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC
 SEC. 107.2.1.
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-05-30 Cont ID  
Sent By tklarge Date 2015-05-30 Time 10:29 Rev Time 0.00
Received By tklarge Date 2015-05-30 Time 10:19 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2015-07-10 Cont ID  
Sent By jgomez Date 2015-07-10 Time 19:43 Rev Time 0.00
Received By jgomez Date 2015-07-10 Time 19:43 Sent To  
Notes
2015-07-10 19:44:27ROOF TILE NOA 11-0321.03.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2015-06-11 Cont ID  
Sent By jgomez Date 2015-06-11 Time 17:16 Rev Time 0.00
Received By jgomez Date 2015-06-11 Time 12:49 Sent To  
Notes
2015-06-11 17:17:28 
 1) NEED ROOF TILE ADHESIVE IF SPECIFIED BY THE ENGINEER
 OF RECORD. SEE ROOF TILE PRODUCT APPROVAL FOR LISTED
 PRODUCTS.
  
 2- THERE WERE TWO ROOF TILE PRODUCT APPROVALS
 SUBMITTED. NOA 11-0321.03 AND FLORIDA PRODUCT APPROVAL
 FL7473-R5 ALONG WITH RIDGE FL PRODUCT APPROVAL
 FL8095-R2. PROVIDE COMPLETE ROOFING PACKAGE EITHER
 MIAMI NOA'S OR COMPLETE PACKAGE FROM FLORIDA PRODUCT
 APPROVAL. MISMATCHING IS NOT ALLOWED.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2015-07-02 Cont ID  
Sent By dkittred Date 2015-07-02 Time 17:21 Rev Time 0.00
Received By dkittred Date 2015-07-02 Time 16:05 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2015-05-26 Cont ID  
Sent By dkittred Date 2015-05-26 Time 09:48 Rev Time 0.00
Received By dkittred Date 2015-05-26 Time 09:45 Sent To  
Notes
2015-05-26 09:48:215/26/15 - CONDITIONAL APPROVAL ISSUED. LANDSCAPE PERMIT
 TO BE SUBMITTED AND LANDSCAPING INSTALLED PRIOR TO C.O.
 SIGNED DOCUMENT ATTACHED TO PLANS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2015-05-08 Cont ID  
Sent By dkittred Date 2015-05-08 Time 13:24 Rev Time 0.00
Received By dkittred Date 2015-05-08 Time 12:53 Sent To  
Notes
2015-05-08 13:24:04PLANNING AND ZONING COMMENTS: ***FAILED***
  
 5/8/2015
  
 1. A SEPARATE LANDSCAPE PERMIT IN CONFORMANCE WITH
 ARTICLE XIV SHALL BE SUBMITTED. (NOTE: ZLDR SEC.
 94-442(B)(2)A. ? FOR SINGLE-FAMILY DWELLING UNITS, AT
 LEAST ONE SHADE, FLOWERING, OR FRUIT TREE SHALL BE
 PLANTED FOR EACH 1,200 SQUARE FEET OF OPEN SPACE OR
 PORTION THEREOF. FOR SINGLE-FAMILY DWELLING UNITS, AT
 LEAST ONE SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE
 FEET OF OPEN SPACE OR PORTION THEREOF. PLEASE ADJUST
 CALCULATIONS TABLE.)
  
 GENERAL COMMENTS:
  
 2. SEPARATE PERMIT REQUIRED FOR POOL AND DRIVEWAY
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  