Plan Review Details - Permit 15040815
| Plan Review Stops For Permit 15040815 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-05-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-05-27 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-05-27 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2015-05-27 09:35:59 | ****PROVISO**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | ALTHOUGH CONTRACTOR HAS INDICATED THAT THE SUBSTRATE IS | | | BLOCK, CBS STRUCTURES TYPICALLY HAVE CONCRETE TOP | | | SUBSTRATE, BLOCK BOTTOM. THE ANCHOR SPACING PROPOSED | | | COMPLIES FOR ANY OF THE INSTALLATION METHODS WITH THE | | | EXCEPTION OF MANY WHICH DO NOT ALLOW INSTALLATION INTO | | | A BLOCK SUBSTRATE. | | | | | | THIS PERMIT IS ISSUED SUBJECT TO A CONCRETE SUBSTRATE | | | AT THE TOP. IF THIS IS NOT THE JOB CONDITION, | | | CONTRACTOR IS TO REVISE THE INSTALLATION SCHEDULE AND | | | SUBMIT (AS A REVISION IF PERMIT IS ALREADY ISSUED, AS A | | | RESUBMITTAL IF PERMIT HAS NOT YET BEEN ISSUED). | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-05-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-05-05 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-05-05 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2015-05-05 14:39:15 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | FBC 2010 RESIDENTIAL 301, RESISTANCE TO WIND LOADS: | | | | | | 1. TWO COMPLETE SETS OF PLANS REQUIRED FOR PERMIT | | | ISSUANCE, FBC 107. FAILURE TO PROVIDE TWO COMPLETE SETS | | | MAY RESULT IN ADDITIONAL FEES CHARGED. | | | | | | 2. PROPOSED INSTALLATION NOT CLEAR. VERTICAL | | | INSTALLATION, SPAN SHOULD CORRELATE WITH THE OPENING | | | SIZE HEIGHT AND EDGE DISTANCE. THIS NUMBER SHOULD BE | | | ANCHOR TO ANCHOR. | | | | | | 3. CONCRETE SUBSTRATE IS STATED. THE BOTTOM IS | | | TYPICALLY A FILLED CELL OR HOLLOW, NOT FORMED AND | | | POURED CONCRETE. PLEASE REVISE OR CLARIFY. | | | | | | 4. 1" EDGE DISTANCE PROPOSED; 3 1/2" REQUIRED OR A | | | FACTOR TO BE APPLIED, SEE CHART ON SHEET 5. MINIMUM | | | EDGE DISTANCE IS 2" FOR PANELMATE (AND REQUIRED A .5 | | | FACTOR). | | | | | | 5. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB, FBC | | | 109. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-05-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-05-27 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-05-14 |
Time |
18:42 |
Sent To |
|
|
| Notes |
| 2015-05-14 18:42:48 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-05-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-05-05 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-05-05 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
|