Plan Review Details - Permit 15040776
Plan Review Stops For Permit 15040776
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2015-05-08 Cont ID  
Sent By tklarge Date 2015-05-08 Time 05:59 Rev Time 0.00
Received By tklarge Date 2015-05-08 Time 05:06 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2015-04-22 Cont ID  
Sent By tklarge Date 2015-04-22 Time 10:45 Rev Time 0.00
Received By tklarge Date 2015-04-22 Time 10:31 Sent To  
Notes
2015-04-22 10:44:451) COPPER TUBING UTILIZED FOR GAS INSTALLATION SHALL
 COMPLY WITH STANDARD TYPE "K" OR "L" OF ASTM B 88 OR
 ASTM B 280 PER THE 2010 FBCR SEC. G2414.5.2. INDICATE
 ON THE PLAN THE TYPE OF COPPER BEING INSTALLED.
 2) COPPER TUBING SHALL NOT BE USED IF THE GAS
 CONCENTRATION CONTAINS MORE THAN AN AVERAGE OF 0.3
 GRAINS OF HYDROGEN SULFIDE PER 100 STANDARD CUBIC FEET
 OF GAS PER THE 2010 FBCR SEC.G2414.5.2. DOCUMENTATION
 FROM THE GAS PURVEYOR AS TO THE AMOUNT OF HYDROGEN
 SULFIDE IN THE GAS WILL BE REQUIRED TO ALLOW THE USE OF
 COPPE TUBING FOR THIS INSTALLATION.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-05-08 Cont ID  
Sent By tlarge Date 2015-05-08 Time 05:58 Rev Time 0.00
Received By tklarge Date 2015-05-06 Time 12:04 Sent To G
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-04-22 Cont ID  
Sent By tklarge Date 2015-04-22 Time 10:45 Rev Time 0.00
Received By tklarge Date 2015-04-21 Time 10:24 Sent To  
Notes
2015-04-22 10:24:34REVISION SENT TO TIM LARGE FOR REVIEW. JG.