Plan Review Details - Permit 15040738
Plan Review Stops For Permit 15040738
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-07-29 Cont ID  
Sent By jgomez Date 2015-07-27 Time 13:47 Rev Time 0.00
Received By jgomez Date 2015-07-27 Time 13:47 Sent To M
Notes
2015-07-27 13:53:14SENT TO CHRIS COLE FOR MECHANICAL REVIEW. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-06-30 Cont ID  
Sent By J GOMEZ Date 2015-06-30 Time 13:37 Rev Time 0.00
Received By jgomez Date 2015-06-30 Time 17:48 Sent To  
Notes
2015-06-30 13:37:27RESIDENTIAL (R3) ADDITION/ALTERATION, SECOND BUILDING
 REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- A) MISSING DRAWINGS. MISSING DRAWINGS A-2, S-1 AND
 S-2..
  
 B) ONE SET OF SHEET S-2 AND S-3 SUBMITTED IS MISSING
 THE ENGINEER'S SEAL. SEC. 471 F.S.
  
 2- ENERGY CALCULATIONS SUBMITTED;
 A) REVISE THE WINDOWS OVERHANG DEPTH AND SEPARATION TO
 MATCH PLANS. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION. (REPEAT COMMENT).
  
 B) REVISE DOOR TYPE TO MATCH PRODUCT APPROVAL AND
 PLANS. NOTE: DOORS WITH GLAZING SHALL BE INCLUDED IN
 THE GLAZING CALCULATIONS. SEE SEC. 405.5.3 OF 2010
 FBC-ENERGY CONSERVATION. (REPEAT COMMENT. THERE ARE NO
 INSULATED DOORS).
  
 C) COMPLETE PAGE 5 OF 5. SEC. 103.2.2 OF 2010
 FBC-ENERGY CONSERVATION. (REPEAT COMMENT).
  
 ***IMPORTANT: WINDOWS AND DOORS LABELS SHOWING THE
 U-FACTORS AND SHGC FACTORS SPECIFIED ON ITEM #7 ARE
 REQUIRED FOR INSPECTION.
  
 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ROOF TILE ADHESIVE AS SPECIFIED ON SHEET S-4. SEE
 ROOF TILE PRODUCT APPROVAL FOR LISTED ADHESIVES.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-05-26 Cont ID  
Sent By jgomez Date 2015-05-26 Time 15:08 Rev Time 0.00
Received By jgomez Date 2015-05-26 Time 14:45 Sent To  
Notes
2015-05-26 15:10:20RESIDENTIAL (R3) ADDITION/ALTERATION, BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  
 2- ENERGY CALCULATIONS SUBMITTED;
 A) WALL TYPES IS MISSING THE FRAMED WALLS OF THE BONUS
 ROOM. SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 B) REVISE THE BUILDING ORIENTATION OF WALLS, DOORS AND
 WINDOWS TO MATCH THE ACTUAL BUILDING ORIENTATION OF THE
 EXISTING HOUSE. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 C) REVISE THE WINDOWS OVERHANG SEPARATION TO MATCH
 PLANS. SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 D) REVISE DOOR TYPE TO MATCH PRODUCT APPROVAL AND
 PLANS. NOTE: DOORS WITH GLAZING SHALL BE INCLUDED IN
 THE GLAZING CALCULATIONS. SEE SEC. 405.5.3 OF 2010
 FBC-ENERGY CONSERVATION.
  
 E) COMPLETE PAGE 5 OF 5. SEC. 103.2.2 OF 2010
 FBC-ENERGY CONSERVATION.
  
 F) COMPLETE ALL THE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER, BUILDER NAME, PERMIT OFFICE AND THE
 JURISDICTION NUMBER. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 3- SEC. R803.2.3.1 OF 2010 FBC-RESIDENTIAL. REQUIRES 8D
 RING SHANK NAILS MIN. FOR ROOF SHEATHING. PLANS CALL
 FOR "ALT: 8D .131 DIA. W/ TYP. NAILING PATTERN".
 PROVIDE ENGINEERING CALCULATIONS SHOWING THAT THE
 ALTERNATIVE NAILS AND NAILING PATTERN ARE EQUAL OR
 BETTER THAN THE MIN. REQUIRED BY SEC. R803.2.3.1. (SEC.
 107.2.1.3 CITY AMENDMENTS). REVISE GENERAL CONSTRUCTION
 NOTES ON SHEET A-1, ROOF FRAMING NOTES ON SHEET S-3 AND
 ALL WALL SECTIONS ON SHEET S-4.
  
 4- SHEET S-4:
 A) ATTIC INSULATION SHOWN ON THE WALL SECTIONS TO MATCH
 ENERGY CALCULATIONS. OPTIONAL R19 IS NOT INCLUDED IN
 THE ENERGY CALCULATIONS. SEC. 103.2.2 OF 2010
 FBC-ENERGY CONSERVATION.
  
 B) FRAMED WALL REQUIRES 7/8" MIN. STUCCO NOT 3/4".
 TABLE R702.1(1) OF 2010 FBC-RESIDENTIAL.
  
 C) ROOF SHEATHING SPECIFICATIONS SHOWN ON GABLE END
 DETAIL 4/S-4 DOESN'T MATCH ROOF SHEATHING SPECS SHOWN
 ON THE OTHER SECTIONS. REVISE AS REQUIRED. SEC. 107.2.1
 CITY AMENDMENTS.
  
 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ROOF TILE.
  
 B) ROOF TILE ADHESIVE. SEE ROOF TILE PRODUCT APPROVAL
 FOR LISTED ADHESIVES.
  
 C) PROVIDE LEGIBLE DRAWINGS FOR PRODUCT APPROVAL
 SUBMITTED FOR SERIES "130 SENTINEL" FIXED WINDOWS,
 SERIES "238 DESIGNER" FIXED WINDOWS, WINDOW MULLIONS,
 SERIES "160 SENTINEL" OUTSWING DOORS AND SERIES "110
 SENTINEL" SINGLE HUNG WINDOWS. DRAWINGS ARE TOO SMALL.
 SEC. 107.2.1.4 CITY AMENDMENTS. PLEASE PRINT DRAWINGS
 IN LANDSCAPE FORMAT INSTEAD OF PORTRAIT FORMAT. THIS
 WAY DRAWINGS WILL BE MORE LEGIBLE.
  
 6- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE REMOVE AND REPLACE ANY REVISED SHEET.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-06-23 Cont ID  
Sent By ALBARRAN Date 2015-06-23 Time 15:00 Rev Time 0.00
Received By skennedy Date 2015-06-22 Time 16:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-05-14 Cont ID  
Sent By albarran Date 2015-05-14 Time 17:10 Rev Time  
Received By albarran Date   Time   Sent To  
Notes
2015-05-14 17:58:30DISPOSITION AND RESPECTIVE COMMENTS FOR ELECTRICAL PLAN
 REVIEW
 APPLICABLE CODES: FBC 2010; WPB AMENDMENTS TO FBC 2010
 CHAPTER 1; NEC 2008
 REVIEW CYCLE: 1ST REVIEW
 ACTION: FAILED AS NOTED BELOW:
 1. INDICATE THE SCALE USED FOR THE DRAWING TO PROPERLY
 ASCERTAIN OUTLET PLACEMENT. ALL OUTLETS SHALL BE AS PER
 NEC 210.52
 2. PER NEC 110.33(B), A PERMANENT LADDER OR STAIRWAY TO
 THE ATTIC WILL BE REQUIRED TO ACCESS THE AHU.
 3. PER NEC 210.63, A SERVICE OUTLET SHALL BE INSTALLED
 IN THE ATTIC WITHIN SIGHT AND NO MORE THAN 25' FROM THE
 AHU
 4. PER NEC 210.70(A)(3), A LIGHT WITH A SWITCH AT THE
 ENTRY TO THE ATTIC SHALL BE INSTALLED INSIDE THE ATTIC
 NEAR THE AHU
 5. PER NEC 210.52(E)(3), AN OUTLET SHALL BE INSTALLED
 IN THE BALCONY
 6. PER NEC 314.27(A), CEILING BOXES SHALL BE LISTED TO
 SUPPORT 50#.
 7. PER FBC-R SEC. 314 & 315, ADDITIONAL DETECTORS MAY
 BE REQUIRED.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-07-29 Cont ID  
Sent By jgomez Date 2015-07-29 Time 11:23 Rev Time 0.00
Received By jgomez Date 2015-07-20 Time 16:32 Sent To  
Notes
2015-07-20 16:32:50RE-SUBMITTAL SENT TO JULIO GOMEZ FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-06-30 Cont ID  
Sent By jgomez Date 2015-06-30 Time 18:03 Rev Time 0.00
Received By jgomez Date 2015-06-10 Time 17:09 Sent To  
Notes
2015-06-11 10:57:44R31

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2015-05-27 Time   Rev Time 0.00
Received By jgomez Date 2015-04-21 Time 12:48 Sent To  
Notes
2015-04-22 12:49:20SENT TO R2 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2015-06-23 Cont ID  
Sent By skennedy Date 2015-06-23 Time 14:24 Rev Time 0.00
Received By jgomez Date 2015-06-22 Time 16:57 Sent To  
Notes
2015-06-30 13:48:32NO FEES. MU-2015-13706. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-05-26 Cont ID  
Sent By jgomez Date 2015-05-26 Time 15:07 Rev Time 0.00
Received By jgomez Date 2015-05-26 Time 15:07 Sent To  
Notes
2015-05-26 15:08:521-BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-07-31 Cont ID  
Sent By ccole Date 2015-07-31 Time 07:23 Rev Time 0.00
Received By ccole Date 2015-07-31 Time 06:50 Sent To  
Notes
2015-07-31 07:33:41MECHANICAL PROVISO:
 7/31/15
 PERMIT #15040738
  
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTIONS(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S).
  
 1) REVISE THE AC EQUIPMENT SCHEDULE ON THE PLAN TO
 MATCH THE EQUIPMENT SPECIFIED IN THE AC LOAD
 CALULATIONS, AND THE ENERGY CALCULATIONS- 2-1/2 TON
 CARRIER SYSTEM.
 2) REVISE THE PLAN TO PROVIDE CODE COMPLIANT ACCESS TO
 THE AIR HANDLER IN THE ATTIC, AND ALL COMPLIANCES
 LISTED UNDER SECTION M1305.1.3.2 FBC-10 RESIDENTIAL-
 SEE ITEMS 1-4.
2015-07-29 13:58:30NEW EQUIPMENT SIZING CALCULATIONS SUBMITTED. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-06-23 Cont ID  
Sent By C COLE Date 2015-06-23 Time 14:08 Rev Time 0.00
Received By skennedy Date 2015-06-22 Time 16:57 Sent To  
Notes
2015-06-23 14:11:261ST REVIEW: FBC 2010
  
 THERE ARE 5 SETS OF A/C LAYOUT DRAWINGS ALL DATED
 4/7/15. NONE ARE SIGNED BY THE DESIGNER. PLEASE PROVIDE
 TWO SETS SIGNED BY THE DESIGNER AND MEETING THE
 COMMENTS FOR THE PREVIOUS REVIEW.
  
  
 FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.
  
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-05-27 Cont ID  
Sent By ccole Date 2015-05-27 Time 10:34 Rev Time 0.00
Received By ccole Date 2015-05-27 Time 10:34 Sent To  
Notes
2015-05-27 11:00:441ST REVIEW: FBC 2010 MECHANICAL
  
 1) THE AC PLANS FROM CMI SHOW THE AIR HANDLER IN THE
 BONUS ROOM ADDITION, HOWEVER THE ELECTRICAL PLANS SHOWS
 IT IN THE ATTIC: PLEASE MAKE THESE PLANS AGREE ON
 LOCATION. SEE SECTION M1305.1.3.2FBC-RESIDENTIAL FOR
 AIR HANDLER IN ATTIC REQUIREMENTS.
 2) SUBMIT MANUAL J AC LOAD WORKSHEETS INDICATING THE
 CALCULATIONS PER EACH ROOM OF THE NEW ADDITION. THE
 SUBMITTED SUMMARY CALC SHEET DOES NOT INDICATE THE
 ADDRESS, DIRECTIONAL ORIENTATION OR AREA CALCULATION-
 SECTION 403.6.1 FBC-10 ENERGY.
 3) THE AC PLAN DOESN'T INDICATE A MEANS OF RETURN AIR
 FROM THE BONUS ROOM- SECTION M1602.4 FBC-10
 RESIDENTIAL.
 4) PROVIDE A PRIMARY CONDENSATE DISPOSAL PLAN- SHOW
 TYPE AND SIZE OF PIPING, PIPING RUN, AND DISCHARGE
 LOCATION. PLACE A NOTE OR DETAIL CLARIFYING HOW
 SECONDARY DISPOSAL WILL BE ACCOMPLISHED- SECTION
 M1411.3 FBC-10 RES.
 5) SHOW THE REFRIGERATION PIPING RUNS ON THE PLAN.
 6) PROVIDE DETAILS FOR INSTALLATION OF THE CONDENSER
 PAD AND TIE DOWN OF THE UNIT PER SECTIONS- M1305.1.4.1
 AND M1307.2.1 FBC-10 RES.
 7) ENERGY EFFICIENCY FORM 405-2010: COMPLETE THE CODE
 COMPLIANCE CHECKLIST ON PAGE 5.
  
 CHRISTOPHER COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2015-07-29 Cont ID  
Sent By jgomez Date 2015-07-29 Time 11:23 Rev Time 0.00
Received By jgomez Date 2015-07-29 Time 11:23 Sent To  
Notes
2015-07-29 11:25:391) ROOF TILE NOA 11-0510.02.
  
 2) TILE FOAM NOA 14-0805.01.
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2015-06-30 Cont ID  
Sent By J GOMEZ Date 2015-06-30 Time 18:03 Rev Time 0.00
Received By jgomez Date 2015-06-30 Time 18:03 Sent To  
Notes
2015-06-30 18:03:411- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ROOF TILE ADHESIVE. SEE ROOF TILE PRODUCT APPROVAL
 FOR LISTED ADHESIVES.
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2015-05-27 Cont ID  
Sent By jgomez Date 2015-05-27 Time 09:13 Rev Time 0.00
Received By jgomez Date 2015-05-27 Time 09:13 Sent To  
Notes
2015-05-27 09:13:371- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ROOF TILE.
  
 B) ROOF TILE ADHESIVE. SEE ROOF TILE PRODUCT APPROVAL
 FOR LISTED ADHESIVES.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2015-06-23 Cont ID  
Sent By S GRAHAM Date 2015-06-23 Time 15:26 Rev Time 0.00
Received By sgraham Date 2015-06-23 Time 15:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-05-08 Cont ID  
Sent By sgraham Date 2015-05-08 Time 12:48 Rev Time 0.00
Received By sgraham Date 2015-05-08 Time 12:48 Sent To  
Notes
2015-05-08 12:49:225/8/15 ZONING FAILED
  
 1. SUBMIT TWO UP TO DATE SURVEYS