Plan Review Details - Permit 15040671
| Plan Review Stops For Permit 15040671 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-05-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-05-27 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-05-27 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-05-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-05-05 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-05-05 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2015-05-05 09:49:38 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PLEASE HAVE ENGINEER VERIFY THE CLASSIFICATION OF | | | "C" FOR EXPOSURE CATEGORY. | | | | | | SEE FBC 2010 RESIDENTIAL 301; IT APPEARS THAT THIS | | | STRUCTURE IS LOCATED LESS THAN 600' FROM THE WATER'S | | | EDGE MEASURING TO THE NORTHEAST (OR TO THE SOUTHEAST). | | | ON THIS ANGLE, THERE IS A FETCH OF OVER APPROX. 5200 | | | FEET. IT APPEARS THAT THIS STRUCTURE IS LOCATED IN | | | EXPOSURE D. | | | | | | EITHER CHANGE THE EXPOSURE CLASSIFICATION TO "D", | | | REVISE OTHER DOCUMENTS AS APPLICABLE, OR PROVIDE A SITE | | | PLAN WHICH SHOWS THE WORST CASE MEASUREMENT IN BOTH | | | DIRECTIONS TO JUSTIFY THE ENGINEER'S CLASSIFICATION OF | | | EXPOSURE C. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-05-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-05-27 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-05-19 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2015-05-20 09:16:40 | RE-SUBMITTAL SENT TO SAMANTHA HILL FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-05-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-05-05 |
Time |
09:49 |
Rev Time |
|
| Received By |
shill |
Date |
2015-04-20 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-04-20 09:42:30 | MISC 1 | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |