|
 |
 |
 |
 |
 |
Plan Review Details - Permit 15040628
| Plan Review Stops For Permit 15040628 |
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-05-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-05-13 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-05-13 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-04-20 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-04-20 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-04-20 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-05-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-05-13 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-05-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-05-05 11:14:36 | SENT TO <$5K PLUMBING BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-04-21 |
Time |
03:41 |
Rev Time |
|
| Received By |
tklarge |
Date |
2015-04-20 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-04-20 16:59:24 | SENT TO <$5K PLUMBING BOX. JW |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-05-06 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-05-06 |
Time |
05:19 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-05-06 |
Time |
04:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-04-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-04-21 |
Time |
03:41 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-04-21 |
Time |
02:40 |
Sent To |
|
|
| Notes |
| 2015-04-21 08:25:01 | 1) SUBMIT A ROOF PLAN SHOWING THE LOCATION AND SIZE OF | | | THE GUTTERS AND DOWNSPOUTS. WPB AMEND. TO 2010 FBC SEC. | | | 107,2,1, | | | 2) THE GUTTERS SHALL BE SIZED PER TABLE 1106.6 OF THE | | | 2010 FPC. SUBMIT CALCULATIONS, | | | 3) SUBMIT A PLAN THAT SHOWS THE SQUARE FOOTAGE OF THE | | | ROOF THAT IS DRAINED BY EACH GUTTER. WPB AMEND. TO 2010 | | | FBC SEC.107.2.1. | | | 4) THE DOWNSPOUTS SHALL BE SIZED PERR THE 2010 FBC | | | TABLE 1106.2 (1) FOR CIRCULAR VERTICAL CONDUCTORS AND | | | LEADERS AND TABLE 1106.2 (2) FOR RECTANGULAR VERTICAL | | | CONDUCTORS AND LEADERS. | | | 5) RAINWATER LEADERS SHALL DISCHARGE A MINIMUM OF ONE | | | FOOT AWAY FROM THE STRUCTURE SIDEWALL PER THE 2010 FBC | | | SEC.1503.7. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-20 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-04-20 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-04-20 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |