Plan Review Details - Permit 15040468
| Plan Review Stops For Permit 15040468 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-09-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-19 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-19 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2015-09-19 13:50:09 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. ONE SET WAS SIGNED OUT BY CONTRACTOR AND WAS NOT | | | RETURNED. TWO SETS REQUIRED FOR PERMIT ISSUANCE, FBC | | | 107. | | | | | | A PHOTOCOPY OF THE ORIGINAL PLAN WAS SUBMITTED, BUT THE | | | PRODUCT APPROVALS WERE NOT SUBMITTED. TWO COMPLETE | | | COLLATED SETS OF PLANS REQUIRED FOR PERMIT ISSUANCE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-09-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-08 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-08 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2015-09-08 07:39:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. ONE SET WAS SIGNED OUT BY CONTRACTOR AND WAS NOT | | | RETURNED. TWO SETS REQUIRED FOR PERMIT ISSUANCE, FBC | | | 107. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-04-30 |
Time |
18:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-04-30 |
Time |
18:37 |
Sent To |
|
|
| Notes |
| 2015-04-30 18:41:28 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. APPLICATION IS NOT CONSISTENT WITH THE PLANS | | | SUBMITTED. APPLICATION IS FOR SHUTTERS, BUT THE PLAN IS | | | FOR WINDOWS AND OTHER RELATED WORK, FBC 107. | | | | | | 2. 1" ANCHOR SPACING PROPOSED. THIS IS NOT ALLOWED PER | | | THE PRODUCT APPROVAL; MINIMUM SPACING IS 3", SEE SHEET | | | 11. | | | | | | 3. VALUE TO INCLUDE LABOR, MATERIALS, OVERHEAD AND | | | PROFIT, FBC 109. PROVIDE A COST BREAKDOWN FOR THIS JOB. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-04-06 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2016-04-06 09:18:54 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-09-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-19 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-09-16 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2015-09-16 13:33:18 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-09-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-09-08 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-08-27 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2015-08-27 13:34:06 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-04-30 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-04-14 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2015-04-21 11:03:14 | TO MISC 1 | | | | | 2015-04-15 14:18:13 | SENT TO SAMANTHA HILL FOR REVIEW. JG. |
|
|
|