Plan Review Details - Permit 15040446
| Plan Review Stops For Permit 15040446 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2015-04-14 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2015-04-14 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2015-04-14 |
Time |
|
Sent To |
FIRE |
|
| Notes |
| 2015-04-14 08:49:46 | APPROVED AS-NOTED: | | | | | | FIRE HYDRANTS APPROVED FOR USE: | | | HYDRANTS SHALL CONFORM TO THE REQUIREMENTS OF AWWA | | | STANDARD C502-94 FOR DRY BARREL HYDRANTS, OR THE LATEST | | | REVISION, AS TO THE DESIGN, COMPONENT MATERIALS, | | | CONSTRUCTION ANDMANUFACTURE, EXCEPT ASMODIFIED OR NOTED | | | IN THE CITY | | | TECHNICAL SPECIFICATIONS (A COPY OF THE SPECIFICATIONS | | | CAN BE SUPPLIED ON REQUEST). APPROVED HYDRANTS SHALL BE | | | USED IN | | | THE CONSTRUCTION OF SYSTEMS TO BE OWNED AND OPERATED BY | | | THE CITY OF WEST PALM BEACH PUBLIC UTILITIES | | | DEPARTMENT. | | | APPROVED HYDRANTS SHALL BE USED IN THE CONSTRUCTION OF | | | PRIVATE SYSTEMS WITH IN THE CORPORATE BOUNDARIES OF THE | | | CITY OF | | | WEST PALM BEACH. | | | AMERICAN B-84-B IS APPROVED FOR USE IN THE CITY OF WEST | | | PALM BEACH. | | | | | | HYDRANT COATINGS: | | | WHEN CONSTRUCTED TO THE CITY OF WEST PALM BEACH | | | TECHNICAL SPECIFICATIONS, HYDRANTS SHALL HAVE A SHOP | | | COAT OF SILVER | | | PAINT APPLIED DURING THE MANUFACTURER. CONTRACTORS | | | SHALL PAINT THE HYDRANT BONNET WITH THE FOLLOWING | | | COATING AFTER | | | INSTALLATION AND PRIOR TO ACCEPTANCE. CONTRACTORS SHALL | | | CLEAN, PREP, AND PAINT ALL DAMAGED FACTORY PAINT. | | | PAINT FOR FIRE HYDRANT BONNET. (REQUIRED) | | | - AXON AEROSPACE, INC.: ALERT SERIES LIGHT REFLECTIVE | | | COATING. DISTRIBUTED BY J. D. L. INDUSTRIES, INC. | | | PAINT FOR BARREL SECTION AND NOZZLE CAPS. (TOUCH-UP | | | PAINT) | | | - SHERMAN-WILLIAMS: SILVER-BRITE ALUMINUM PAINT. TWO | | | NUMBERS ON THE CAN ARE B59-511 AND 631-1336 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-04-30 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-04-30 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-04-30 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-04-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-04-22 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-04-22 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2015-04-22 13:39:04 | 831 VILLAGE BOULEVARD | | | PERMIT #15040446 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PER NFPA 24 - INSTALLATION OF PRIVATE FIRE SERVICE | | | MAINS AND THEIR APPURTENANCES | | | 1.1.1 THIS STANDARD SHALL COVER THE MINIMUM | | | REQUIREMENTS FOR THE INSTALLATION OF PRIVATE FIRE | | | SERVICE MAINS AND THEIR APPURTENANCES SUPPLYING THE | | | FOLLOWING: | | | (1) AUTOMATIC SPRINKLER SYSTEMS | | | (2) OPEN SPRINKLER SYSTEMS | | | (3) WATER SPRAY FIXED SYSTEMS | | | (4) FOAM SYSTEMS | | | (5) PRIVATE HYDRANTS | | | | | | 1.1.2 THIS STANDARD SHALL APPLY TO COMBINED SERVICE | | | MAINS USED TO CARRY WATER FOR FIRE SERVICE AND OTHER | | | USES. | | | | | | THE STATE OF FLORIDA REQUIRES A FIRE PROTECTION SYSTEM | | | TO BE INSTALLED BY A LICENSED "CONTRACTOR I, II, III, | | | IV OR V." THE CONTRACTOR "MIGUEL LOPEZ JR. INC" | | | (LICENSE #CUC057030) IS ONLY LICENSED AS AN | | | "UNDERGROUND UTILITY CONTRACTOR" AND NOT A "CONTRACTOR | | | V" AS IS REQUIRED BY THE FLORIDA STATE FIRE MARSHAL. | | | THE CLASS V LICENSE EXPIRED 06/30/2010. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-04-30 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-04-30 |
Time |
10:54 |
Sent To |
FIRE |
|
| Notes |
| 2015-04-14 08:26:36 | SENT TO ENGINEERING, CUSTOMER TOOK PLANS UP TO MANNY |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2015-04-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-04-30 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-04-30 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
|