| 2015-04-25 10:01:05 | BUILDING PLAN REVIEW |
| | W. P. B. REVISION: 15040415 |
| | W. P. B. PERMIT: 14120661 |
| | ADD: 2601 OKEECHOBEE BLVD. |
| | CONT: ANDERSON MOORE CONST. |
| | TEL: (561) 662-1819 |
| | E-MAIL: |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | IMPORTANT NOTICE: EFFECTIVE JUNE 01, 2015 |
| | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| | ELECTRONICALLY |
| | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| | SUBMISSION OPTIONS ARE AS FOLLOWS: |
| | 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| | NAMING CONVENTION FOR EACH DOCUMENT |
| | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| | AVAILABLE |
| | |
| | 1ST REVIEW |
| | DATE: SAT. APRIL 25/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) THIS SET OF PLANS WAS BROUGHT IN AS A REVISION BUT |
| | HAS NOTHING TO DO WITH THE BURLINGTON COAT FACTORY. |
| | SHEETS A3.04 - A3.08 NOTE 88 INDICATES THIS IS A (1) |
| | HOUR FIRE RATED WALL THAT SEPARATES THE STORE TENANCY |
| | FROM THE LANDLORD COMMON AREAS. SEE THE DIFINITION OF |
| | GROSS LEASABLE AREA: |
| | GROSS LEASABLE AREA. THE TOTAL FLOOR AREA DESIGNED FOR |
| | TENANT OCCUPANCY AND EXCLUSIVE USE. THE AREA OF TENANT |
| | OCCUPANCY IS MEASURED FROM THE CENTERLINES OF JOINT |
| | PARTITIONS TO THE OUTSIDE OF THE TENANT WALLS. ALL |
| | TENANT AREAS, INCLUDING AREAS USED FOR STORAGE, SHALL |
| | BE INCLUDED IN CALCULATING GROSS LEASABLE AREA. |
| | THE WORK BEING COMPLETED UNDER THE LANDLORD COMMON |
| | AREAS CAN BE ONE SEPARATE PERMIT FOR THE (5) AREAS OF |
| | WORK. WHEN PLANS COME IN FOR SIGNAGE, THEN EACH |
| | TENACNCY WOULD REQUIRE THEIR OWN SIGN PERMITS. |
| | |
| | 2) THIS PLAN ON THE ARCHITECTURAL SHEETS AND STUCTURAL |
| | SHEETS S-2.2 & S-3.0 SHOW STEEL COLUMNS, ANGLE BRACING, |
| | BRIDGING AND STEEL BEAMS THAT WILL REQUIRE |
| | FIELD WELDING AND BOLTABLE CONNECTIONS. THIS TYPE OF |
| | CONSTRUCTION WILL REQUIRE A RESIDENT INSPECTOR. |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER |
| | INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, |
| | OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED |
| | BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS |
| | OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER |
| | INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR |
| | QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED |
| | FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT |
| | BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING |
| | AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. |
| | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY |
| | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: |
| | |
| | 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II |
| | CONSTRUCTION |
| | 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS |
| | 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE |
| | STRENGTH (F ?C) IN EXCESS OF 3000 |
| | POUNDS PER SQUARE INCH |
| | 4. FOR PILE DRIVING |
| | 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE |
| | FOOT |
| | 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT |
| | 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR |
| | METHODS OF CONSTRUCTION |
| | |
| | 2A) FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' |
| | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE |
| | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS |
| | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE |
| | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, |
| | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES |
| | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST |
| | MEETING THE ABOVE CRITERIA. |
| | CONTACT KEN CONRAD |
| | TEL: 561-805-6666 |
| | E-MAIL: [email protected] |
| | |
| | 2B) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR |
| | HISTORY FOR THIS TYPE OF CONSTRUCTION. THIS MAY BE |
| | SUBMITTED TO KEN CONRAD BY E-MAIL. KEN CONRAD: |
| | [email protected] |
| | |
| | 2C) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE |
| | REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, THE |
| | PERMIT LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND |
| | BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO |
| | SETS OF PLANS WILL NEED TO BE PRINTED IN COLOR, (1) FOR |
| | THE RESIDENT INSPECTOR, THE OTHER FOR THE MEP |
| | INSPECTORS. |
| | |
| | 2D) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED |
| | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR |
| | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE |
| | INSPECTIONS. |
| | |
| | 3) THE PLANS FAIL TO INDICATE COMPLIANCE WITH THE |
| | PROTECTION OF PEDESTRIANS INTO EACH OF THE TENANCIES |
| | WHILE WORK ON THE COVERED ENTRY ENTRY WAYS ARE UNDER |
| | CONSTRUCTION. 2010 FBC-B 3306.5 BARRIERS & 3306.7 |
| | COVERED WALKWAYS. |
| | |
| | 4) [F] 3309.1 WHERE REQUIRED. ALL STRUCTURES UNDER |
| | CONSTRUCTION, ALTERATION OR DEMOLITION SHALL BE |
| | PROVIDED WITH NOT LESS THAN ONE APPROVED PORTABLE FIRE |
| | EXTINGUISHER IN ACCORDANCE WITH SECTION 906. |
| | |
| | 5) 3309.2 FIRE HAZARDS. THE PROVISIONS OF THIS CODE AND |
| | THE FLORIDA FIRE PREVENTION CODE SHALL BE STRICTLY |
| | OBSERVED TO SAFEGUARD AGAINST ALL FIRE HAZARDS |
| | ATTENDANT UPON CONSTRUCTION OPERATIONS. |
| | |
| | 6) SHOW COMPLIANCE WITH: 3310.2 MAINTENANCE OF MEANS OF |
| | EGRESS. REQUIRED MEANS OF EGRESS SHALL BE MAINTAINED AT |
| | ALL TIMES DURING CONSTRUCTION, DEMOLITION, REMODELING |
| | OR ALTERATIONS AND ADDITIONS TO ANY BUILDING. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | |
| | |
| | |
| | |