Plan Review Details - Permit 15040359
| Plan Review Stops For Permit 15040359 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-05-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-06 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-06 |
Time |
08:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-04-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-29 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-29 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2015-04-29 17:38:54 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | FBC-R 301.1 BUILDINGS AND STRUCTURES, AND ALL PARTS | | | THEREOF, SHALL BE CONSTRUCTED TO SAFELY SUPPORT ALL | | | LOADS, INCLUDING DEAD LOADS, LIVE LOADS, ROOF LOADS, | | | FLOOD LOADS, AND WIND LOADS AS PRESCRIBED BY THIS CODE. | | | THE CONSTRUCTION OF BUILDINGS AND STRUCTURES IN | | | ACCORDANCE WITH THE PROVISIONS OF THIS CODE SHALL | | | RESULT IN A SYSTEM THAT PROVIDES A COMPLETE LOAD PATH | | | THAT MEETS ALL REQUIREMENTS FOR THE TRANSFER OF ALL | | | LOADS FROM THEIR POINT OF ORIGIN THROUGH THE | | | LOAD-RESISTING ELEMENTS TO THE FOUNDATION. | | | | | | 1) SPECIFY THE SIZE OF THE HEADER THAT WILL CARRY THE 2 | | | X 8 RAFTERS AND BE ATTACHED TO THE 4 X 4 POSTS. | | | | | | 2) SPECIFY THE CONNECTORS THAT WILL BE USED TO ANCHOR | | | THE 4 X 4 POSTS TO THE 10 X 10 X 12 CONCRETE PADS AND | | | TO THE HEADER BEAM. | | | | | | 3) SPECIFY HOW THE DOUBLE 2 X 8 P.T. LEDGER WILL BE | | | ATTACHED TO THE EXISTING STRUCTURE. | | | | | | 4) THE DESIGN CRITERIA SPECIFIES ASCE 7 - 02 WHICH IS | | | NOT THE EDITION THAT IS REFERENCED BY THE 2010 FBC. | | | UPDATE TO ASCE 7 - 10. THE OCCUPANCY TYPE IS R-3, NOT | | | TYPE V. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-05-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-06 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-05-04 16:45:44 | SENT TO R. MCDOUGALS' DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-29 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-10 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2015-04-11 07:58:40 | SENT TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-04-16 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-04-16 |
Time |
10:56 |
Rev Time |
|
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|
|