Plan Review Details - Permit 15040308
Plan Review Stops For Permit 15040308
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-06-08 Cont ID  
Sent By jgomez Date 2015-06-08 Time 17:06 Rev Time 0.00
Received By jgomez Date 2015-06-08 Time 17:06 Sent To  
Notes
2015-06-08 17:16:06RESIDENTIAL (R3) ADDITION BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT AND
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
  
 2- THIS IS NOT A LEVEL 2 ALTERATION. THIS IS AN
 ADDITION. REVISE CODE ANALYSIS INFORMATION AS REQUIRED.
 SEC.401.4 OF 2010 FBC-EXISTING BUILDING.
  
 3- PROVIDE SPECIFICATIONS SHOWING COMPLIANCE WITH THE
 HEATING REQUIREMENTS OF SEC. R303.8 OF 2010
 FBC-RESIDENTIAL.
  
 4- WALL SECTION ON SHEET 2:
 A) NEED TO SPECIFY MIN. 8D RING SHANK NAILS AS REQUIRED
 BY SEC. R803.2.3.1 OF 2010 FBC-RESIDENTIAL. ALSO, NAIL
 SPACING AND ROOF ZONES ARE NOT CLEAR. WHAT'S 74" O.C.
 IN ZONE 3?
  
 B) SPECIFY ROOF SLOPE. SEC. R905.9.1 OF 2010
 FBC-RESIDENTIAL.
  
 C) ROOF VENTILATION: 4" X 24" VENT DOESN'T PROVIDE
 CROSS VENTILATION AS REQUIRED BY SEC. R806 OF 2010
 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 D) SPECIFY 7/8" STUCCO THICKNESS AS REQUIRED BY TABLE
 R702.1(1) OF 2010 FBC-RESIDENTIAL.
  
 E) WHERE IS THE GABLE END BALLOON FRAMING SPECIFIED ON
 THE SECTION?. SEC. 107.2.1 CITY AMENDMENTS.
  
 F) SPECIFY WALL INSULATION. COORDINATE WITH THE ENERGY
 CALCULATIONS. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION
  
 G) REVISE ROOF INSULATION TO MATCH THE ENERGY
 CALCULATIONS. NOTE: ENERGY CALCULATIONS SUBMITTED
 REQUIRE R-30 INSULATION. R-30 BATT INSULATION DOESN'T
 FIT ON 2 X8 CEILING JOISTS. R-30 REQUIRES 9 1/2"
 INCHES. IN ADDITION INSULATION NEEDS TO ALLOW AT LEAST
 1 INCH OF SPACE FOR ROOF CROSS VENTILATION. SEC.
 103.2.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 H) SPECIFY CONNECTOR AT THE BASE OF THE WOOD STUDS.
 SEC. R601.2 OF 2010 FBC-RESIDENTIAL.
  
 I) SPECIFY HOW MUCH EMBEDMENT IS REQUIRED FOR THE 1/2"
 ANCHOR BOLTS SPECIFIED TO FASTEN THE BOTTOM WOOD
 PLATES. SEC. R601.2 OF 2010 FBC-RESIDENTIAL.
  
 J) NEED TO SPECIFY ^" MIN. CLEARANCE FROM GRADE AS
 REQUIRED BY SEC. R404.1.6 OF 2010 FBC-RESIDENTIAL.
  
 K) NEED TO SPECIFY THE 12" MIN. DEPTH AS REQUIRED BY
 SEC. R403.1.4 OF 2010 FBC-RESIDENTIAL.
  
 L) NEED TO SPECIFY THE CONCRETE SLAB VAPOR BARRIER AS
 REQUIRED BY SEC. R405.2.2 OF 2010 FBC-RESIDENTIAL.
  
 5- ROOF FRAMING PLAN ON SHEET 2:
 A) SPECIFY ROOF SLOPE AS REQUIRED BY SEC. R905.9.1 OF
 2010 FBC-RESIDENTIAL.
  
 B) SPECIFICATIONS ON ROOF PLAN CALL FOR 2" X 8" JOISTS
 @ 24"O.C.. FLOOR PLAN DOESN'T SHOW 24" O.C. SPACING.
 REVISE AS REQUIRED. SEC107.2.1 CITY AMENDMENTS.
  
 C) GIVEN THE JOIST SIZE, SPACING AND SPAN SHOWN ON ROOF
 PLAN PROVIDE CALCULATIONS SHOWING THAT IS ADEQUATE FOR
 THE LOADS SPECIFIED ON SHEET 1 OF 2. OR PROVIDE TABLE
 THAT CONFIRMS LOADS BASED ON THE SIZE AND SPAN SHOWN ON
 PLANS. SEC. R301.1 OF 2010 FBC-RESIDENTIAL AND SEC.
 107.2.1.3 CITY AMENDMENTS.
  
 6- FRAMING DETAIL ON SHEET 2 OF 2 DOESN'T MATCH
 INFORMATION SHOW ON WALL SECTION "A". REVISE AS
 REQUIRED. ALSO, THERE ARE NOT EXISTING HEADERS. THIS IS
 AN ADDITION (NEW CONSTRUCTION). WHY THERE ARE NOT
 CRIPPLE STUDS FOR WINDOW FRAMING. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 7- ARCHITECT TO PROVIDE ALL HIS INFORMATION IN THE
 TITLE BLOCK AS REQUIRED BY SEC. 61G1-16.004 OF FLORIDA
 ADMINISTRATIVE CODE AND CHAPTER 481 F.S.
  
 8- ENERGY CALCULATIONS SUBMITTED:
 A) FORM 402-2010 IS INCOMPLETE. IS MISSING THE BOTTOM
 PART WHERE OWNER/AGENT NEEDS TO CERTIFY COMPLIANCE.
 PROVIDE FULL FORM SIGNED BY AND DATED BY THE
 OWNER/AGENT. SEC. 103.2.3.2 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 B) COMPLETE INFORMATION ON TOP OF FORM, INCLUDING
 OWNER, PERMITTING OFFICE AND JURISDICTION #. SEC.
 107.2.1 CITY AMENDMENTS.
  
 C) ITEM # 10 REQUIRES R-30 INSULATION AS REQUIRED BY
 GENERAL INSTRUCTION #2. TABLE 402A REQUIRES R30 CEILING
 INSULATION. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 9- FLAT ROOF NOA 14-0611.01 SUBMITTED: PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS AS REQUIRED BY GENERAL
 LIMITATION # 7 ON LAST PAGE OF NOA SUBMITTED. NEED THE
 CALCULATIONS TO MEET THE DESIGN PRESSURES OF SEC.
 R301.1 OF 2010 FBC-RESIDENTIAL.
  
 10-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) SINGLE HUNG WINDOWS. PROVIDE THE FLORIDA PRODUCT
 APPROVAL COVER PAGE FOR DRAWINGS SUBMITTED. IF THERE IS
 NOT FLORIDA PRODUCT APPROVAL , THEN MANUFACTURER MAY
 APPLY FOR LOCAL PRODUCT APPROVAL.
  
 B) EXTERIOR SWING DOOR. PROVIDE THE FLORIDA PRODUCT
 APPROVAL COVER PAGE FOR DRAWINGS SUBMITTED. IF THERE IS
 NOT FLORIDA PRODUCT APPROVAL , THEN MANUFACTURER MAY
 APPLY FOR LOCAL PRODUCT APPROVAL.
  
 C) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR
 LIST THE FLORIDA PRODUCT APPROVAL NUMBER ON DRAWINGS
 NEXT TO THE SPECIFIED CONNECTOR.
  
 11- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN
 WRITING (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS
 AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 ****PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-06-01 Cont ID  
Sent By albarran Date 2015-06-01 Time 16:41 Rev Time 0.00
Received By albarran Date 2015-06-01 Time 16:32 Sent To  
Notes
2015-06-01 16:52:19THE FOLLOWING ITEMS SHALL BE CORRECTED AND THE PLANS
 RESUBMITTED FOR A SECOND REVIEW:
  
  
 THESE PLANS WERE REVIEWED FOR COMPLIANCE WITH THE 2008
 EDITION OF THE NEC, THE 2013 EDITION OF THE NFPA72, THE
 APPLICABLE CHAPTERS OF THE 2010 EDITION OF THE FLORIDA
 BUILDING CODE, FLORIDA BUILDING CODE RESIDENTIAL AND
 FLORIDA BUILDING CODE ENERGY CONSERVATION.
 1. HOWEVER SMALL IT MAY BE, ACCORDING TO THE 2008
 EDITION OF THE NEC, YOU SHALL SUBMIT A PANEL SCHEDULE
 ALONG WITH A LOAD CALC OF THE EXISTING SERVICE
 REFLECTING THE ADDED LOAD TO MAKE CERTAIN THAT THE
 EXISTING SERVICE IS CAPABLE OF ABSORBING THE ADDED
 LOAD.
 2. YOU SHALL ADHERE TO THE REQUIREMENTS OF THE FBC-R
 314 & 315 WHICHEVER IS APPLICABLE.
 3. LIGHTING IS REQUIRED IN THE LAUNDRY AREA, PER NEC
 210.70
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS
  
 FOR QUESTIONS ON THE ABOVE, PLEASE CONTACT:
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 PH: (561) 805-6743
 EMAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-06-09 Cont ID  
Sent By jgomez Date 2015-06-09 Time 17:55 Rev Time 0.00
Received By jgomez Date 2015-04-09 Time 14:33 Sent To  
Notes
2015-04-09 14:33:27R06
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-06-08 Cont ID  
Sent By jgomez Date 2015-06-08 Time 17:16 Rev Time 0.00
Received By jgomez Date 2015-06-08 Time 17:16 Sent To  
Notes
2015-06-08 17:16:301- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT AND
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-05-14 Cont ID  
Sent By tklarge Date 2015-05-14 Time 09:20 Rev Time 0.00
Received By tklarge Date 2015-05-14 Time 08:28 Sent To  
Notes
2015-05-14 09:19:49THE DESCRIPTION OF WORK ON THE APPLICATION NOTES "ADD
 LAUNDRY ROOM AREA" BUT PLUMBING DETAILS HAVE NOT BEEN
 SUBMITTED ON THE PLANS. SUBMIT A SANITARY AND WATER
 RISER DIAGRAM FOR REVIEW. WPB AMEND. TO 2010 FBC SEC.
 107.3.5.3.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2015-06-09 Cont ID  
Sent By jgomez Date 2015-06-09 Time 17:54 Rev Time 0.00
Received By jgomez Date 2015-06-09 Time 17:54 Sent To  
Notes
2015-06-09 17:55:41FLAT ROOF NOA 14-0611.01. NEED RAS 117 CALCULATIONS.

Review Stop Z ZONING
Rev No 1 Status P Date 2015-04-10 Cont ID  
Sent By sgraham Date 2015-04-10 Time 13:53 Rev Time 0.00
Received By sgraham Date 2015-04-10 Time 13:53 Sent To  
Notes
***NONE***