Plan Review Details - Permit 15040239
Plan Review Stops For Permit 15040239
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2015-10-19 Cont ID  
Sent By rmcdouga Date 2015-10-19 Time 18:58 Rev Time 0.00
Received By jgomez Date 2015-10-19 Time 18:23 Sent To E
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-09-24 Cont ID  
Sent By gomez Date 2015-09-23 Time 18:15 Rev Time 0.00
Received By jgomez Date 2015-09-23 Time 18:15 Sent To  
Notes
2015-09-23 18:46:42RESIDENTIAL (R3) ADDITION, THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: 2010 RESIDENTIAL
  
 1- EGRESS FROM EXISTING BEDROOM IS GOING TO BE BLOCKED
 BY THE NEW PORCH ADDITION. NEED TO PROVIDE COMPLIANCE
 WITH THE EGRESS REQUIREMENTS OF SEC. R310 OF 2010
 FBC-RESIDENTIAL. SPECIFY IF THERE IS AN EGRESS WINDOW
 ON THE SOUTH SIDE OF THE EXISTING BEDROOM. IF SO, THEN
 SPECIFY LOCATION SIZE AND TYPE OF WINDOW ON THE SOUTH
 SIDE.. (REPEAT COMMENT. NOT ADDRESSED).
  
 2- SPECIFY CARBON MONOXIDE ALARMS WITHIN 10 FEET OF
 EACH SLEEPING ROOM AS REQUIRED BY SEC. R315 OF 2010
 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED).
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ****PLESE REMOVE AND REPLACE ANY REVISED SHEET. SUBMIT
 OLD SET FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT.
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-07-23 Cont ID  
Sent By jgomez Date 2015-07-23 Time 10:16 Rev Time 0.00
Received By jgomez Date 2015-07-23 Time 10:16 Sent To  
Notes
2015-07-23 10:33:33RESIDENTIAL (R3) ADDITION, SECOND BUILDING REVIEW
 COMMENTS.
 CODE: 2010 RESIDENTIAL
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) FOR IMPACT FEES ASSESSMENT.
 COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND
 DEVELOPMENT CODE. (REPEAT COMMENT. NOT ADDRESSED).
  
 2-CLARIFY IF NEW PORCH IS GOING TO BE SCREENED OR NOT.
 ELEVATIONS DON'T SHOW THE SCREEN BUT FLOOR PLAN ON
 SHEET 2 OF 5 SAYS "SCREEN PORCH". PROVIDE COMPLETE
 DETAILS AND SPECIFICATIONS FOR THE CONSTRUCTION AND
 INSTALLATION OF THE SCREEN ENCLOSURE SHOWING COMPLIANCE
 WITH SEC. R301.1 OF 2010 FBC-RESIDENTIAL.
  
 3- NEW CODE ANALYSIS INFORMATION ON SHEET 1 OF 5: THIS
 IS NOT ALTERATION LEVEL 2. THIS IS AN ADDITION. REVISE
 AS REQUIRED. SEC. 407 OF 2010 FBC-EXISTING BUILDING.
  
 4- FLOOR PLAN ON SHEET 2 OF 5:
 A) EGRESS FROM EXISTING BEDROOM IS GOING TO BE BLOCKED
 BY THE NEW PORCH ADDITION. NEED TO PROVIDE COMPLIANCE
 WITH THE EGRESS REQUIREMENTS OF SEC. R310 OF 2010
 FBC-RESIDENTIAL. SPECIFY IF THERE IS AN EGRESS WINDOW
 ON THE SOUTH SIDE OF THE EXISTING BEDROOM. IF SO, THEN
 SPECIFY LOCATION SIZE AND TYPE OF WINDOW ON THE SOUTH
 SIDE.. (REPEAT COMMENT. NOT ADDRESSED).
  
 B) SPECIFY CARBON MONOXIDE ALARMS WITHIN 10 FEET OF
 EACH SLEEPING ROOM AS REQUIRED BY SEC. R315 OF 2010
 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED).
  
 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ROOF SHINGLES. NOTE: THERE WERE TWO DIFFERENT
 PRODUCT APPROVALS SUBMITTED. FLORIDA PRODUCT APPROVAL
 FL10124-R14 AND MIAMI-DADE NOA 11-1122.04. CLARIFY
 WHICH ONE IS GOIN TO BE USED. ALSO, THERE IS A REVIEW
 AND APPROVE STAMP ON THE MIAMI-DADE NOA 11-1122.04.
 CLARIFY WHO REVIEWED AND APPROVED IT.. AND WHY THE
 DRAWINGS ARE NOT SIGNED AND SEALED BY THE SAME PERSON?
  
 B) PRECAST LINTELS SPECIFIED ON SHEET 3 OF 3. (REPEAT
 COMMENT).
  
 6- PROVIDE THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. 107.2.1
 CITY AMENDMENTS. PLANS ARE MISSING THE NAME OF THE
 PERSON RESPONSIBLE FOR THE DESIGN. NOTE: COORDINATE
 ITEM #5 (A) ABOVE.
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ****PLESE REMOVE AND REPLACE ANY REVISED SHEET. SUBMIT
 OLD SET FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT.
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-05-20 Cont ID  
Sent By jgomez Date 2015-05-20 Time 14:45 Rev Time 0.00
Received By jgomez Date 2015-05-20 Time 14:43 Sent To  
Notes
2015-05-20 14:46:03RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS.
 CODE: 2010 RESIDENTIAL
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) FOR IMPACT FEES ASSESSMENT.
 COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND
 DEVELOPMENT CODE.
  
 2-REVISE THE DESIGN PARAMETERS INFORMATION SHOWN ON
 SHEET 1 OF 5:
 A) THE CURRENT CODE IS 2010 FBC-RESIDENTIAL NOT 2001
 FBC
  
 B) THE BUILDING EXPOSURE CATEGORY IS "C" NOT "B".
 REVISE AS REQUIRED. SEC. R301.2.1.4 AND SEC.
 R301.2.1.4.2 OF 2010 FBC-RESIDENTIAL.
  
 C) BASIC WIND SPEED OF 140 MPH IS NOT THE RIGHT WIND
 SPEED UNDER THE CURRENT CODE 2010 FBC-RESIDENTIAL.
 REVISE AS REQUIRED. SPECIFY THE ULTIMATE WIND SPEED AND
 THE NOMINAL WIND SPEED AS REQUIRED BY SEC. R301.2.1.3
 OF 2010 FBC-RESIDENTIAL.
  
 D) SPECIFY THE ATTIC LIVE LOAD AS REQUIRED BY TABLE
 R301.5 OF 2010 FBC-RESIDENTIAL.
  
 E) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION AND INSTALLATION OF THE SCREEN ENCLOSURE
 SHOWING COMPLIANCE WITH SEC. R301.1 OF 2010
 FBC-RESIDENTIAL.
  
 3- FLOOR PLAN ON SHEET 2 OF 5:
 A) EGRESS FROM EXISTING BEDROOM IS GOING TO BE BLOCKED
 BY THE NEW SCREENED PORCH ADDITION. NEED TO PROVIDE
 COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. R310 OF
 2010 FBC-RESIDENTIAL.
  
 B) SPECIFY ATTIC ACCESS. SEC. R807 OF 2010
 FBC-RESIDENTIAL.
  
 C) SPECIFY CARBON MONOXIDE ALARMS WITHIN 10 FEET OF
 EACH SLEEPING ROOM AS REQUIRED BY SEC. R315 OF 2010
 FBC-RESIDENTIAL.
  
 4- FOUNDATION PLAN ON SHEET 3 OF 5:
 A) CLARIFY SIZE OF FOOTING SPECIFIED. 18" X 8" ?. SEC.
 107.2.1 CITY AMENDMENTS.
  
 B) INFORMATION ON LINTEL DETAIL IS NOT CLEAR. LETTERING
 IS TOO SMALL AND IS NOT LEGIBLE. SEC. 107.2.1.4 CITY
 AMENDMENTS. AND, COORDINATE INFORMATION WITH TYP. WALL
 SECTION ON SHEET 5 OF 5. NOTE: THERE ARE NO WINDOW OR
 DOOR OPENINGS ON THE ENCLOSED PORCH. THE WALLS SHOWN ON
 THIS PLAN ARE FOR A 2'-8" LOW WALLS ONLY. THEY DON'T GO
 ALL THE WAY UP TO THE BOTTOM OF THE BEAM. PROVIDE CLEAR
 AND COMPLETE DETAILS AND SPECIFICATIONS FOR BEAM
 BETWEEN PORCH COLUMNS SHOWING COMPLIANCE WITH SEC.
 R601.2 OF 2010 FBC-RESIDENTIAL.
  
 5- ROOF PLAN ON SHEET 4 OF 5:
 A) TRUSS CONNECTOR (HETA 20) DOESN'T WORK FOR THE
 EXISTING WALL. IT CAN NOT BE EMBEDDED INTO THE EXISTING
 TIE BEAM. REVISE AS REQUIRED. SEC. R801.2 OF 2010
 FBC-RESIDENTIAL.
  
 B) STRAPPING SCHEDULE SPECIFIES CONNECTOR "TO CONCRETE
 BEAM" . WHERE IS THE CONCRETE BEAM. CLARIFY AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 6- TYPICAL WALL SECTION ON SHEET 5 OF 5:
 A) MOST OF THE INFORMATION IS NOT CLEAR. LETTERING IS
 TOO SMALL AND IS NOT LEGIBLE. REVISE AS REQUIRED. SEC.
 107.2.1 CITY AMENDMENTS.
  
 B) REVISE ROOF SHEATHING NAILING SPECIFICATIONS. NEED
 TO USE MIN. 8D RING SHANK NAILS AS REQUIRED BY SEC.
 R803.2.3.1 OF 2010 FBC-RESIDENTIAL.
  
 C) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION AND INSTALLATION OF THE SOFFIT TO SHOW
 COMPLIANCE WITH THE DESIGN PRESSURES AS REQUIRED BY
 SEC. R703.1.3 OF 2010 FBC-RESIDENTIAL.
  
 D) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 PORCH CEILING CONSTRUCTION AND INSTALLATION. PROVIDE
 COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301.1.
 ALSO, PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 5/8 DRYWALL. TAKE INTO CONSIDERATION THAT THIS IS AN
 EXTERIOR APPLICATION.
  
 E) PROVIDE LEGIBLE AND CLEAR SPECIFICATIONS FOR THE
 BEAM. REMEMBER THAT THIS IS NOT A CONTINUOUS WALL. THIS
 IS AN ENCLOSED PORCH SUPPORTED ON COLUMNS. SEC. R801.2
 OF 2010 FC-RESIDENTIAL.
  
 F) COORDINATE INFORMATION ON TYP. WALL & BEAM
 ATTACHMENT DETAIL WITH TYP. WALL SECTION. COORDINATE
 BEAM SPECIFICATIONS AND THERE IS NOT CONCRETE BLOCK
 WALL. THEY ARE JUST COLUMNS AND BEAM. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 G) SPECIFY SIZE OF SOFFIT VENT TO SHOW COMPLIANCE WITH
 SEC. R806 OF 2010 FBC-RESIDENTIAL.
  
 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ROOF SHINGLES.
  
 B) SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS.
 PROVIDE THE PRODUCT APPROVAL NUMBER NEXT TO THE
 SPECIFIED CONNECTOR OR PROVIDE COPY OF PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR.
  
 C) PRECAST LINTEL SPECIFIED ON LINTEL DETAIL.
  
 8- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION WAS UPDATED TO $13, 000. THE
 PERMIT FEE BALANCE IS $339.78.
  
 9- PROVIDE THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. 107.2.1
 CITY AMENDMENTS.
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ****PLESE REMOVE AND REPLACE ANY REVISED SHEET.
 RESUBMIT OLD SET FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT.
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2015-10-19 Cont ID  
Sent By jgomez Date 2015-10-19 Time 18:41 Rev Time 0.00
Received By rmcdouga Date 2015-10-19 Time 18:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-09-09 Cont ID  
Sent By mcdougal Date 2015-09-09 Time 15:27 Rev Time 0.00
Received By skennedy Date 2015-09-09 Time 15:27 Sent To  
Notes
2015-09-09 15:28:19TO JG DESK

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-07-21 Cont ID  
Sent By rmcdouga Date 2015-07-21 Time 09:14 Rev Time 0.00
Received By rmcdouga Date 2015-07-21 Time 09:14 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-05-21 Cont ID  
Sent By rmcdouga Date 2015-05-21 Time 18:16 Rev Time 0.00
Received By rmcdouga Date 2015-05-21 Time 18:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-10-19 Cont ID  
Sent By rmcdouga Date 2015-10-19 Time 18:58 Rev Time 0.00
Received By rmcdouga Date 2015-10-13 Time 16:09 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-09-23 Cont ID  
Sent By jgomez Date 2015-09-23 Time 18:53 Rev Time 0.00
Received By jgomez Date 2015-09-04 Time 14:46 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-07-23 Cont ID  
Sent By jgomez Date 2015-07-23 Time 10:57 Rev Time 0.00
Received By jgomez Date 2015-07-10 Time 14:46 Sent To  
Notes
2015-07-10 14:47:56ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-05-21 Cont ID  
Sent By rmcdouga Date 2015-05-21 Time 18:16 Rev Time 0.00
Received By rmcdouga Date 2015-04-07 Time 09:43 Sent To  
Notes
2015-04-08 09:44:11SENT TO R19 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2015-09-23 Cont ID  
Sent By gomez Date 2015-09-23 Time 18:52 Rev Time 0.00
Received By jgomez Date 2015-09-23 Time 18:52 Sent To  
Notes
2015-09-23 18:53:10NO FEES DUE. COUNTY STAMP DATED 8/31/15.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-07-23 Cont ID  
Sent By jgomez Date 2015-07-23 Time 10:57 Rev Time 0.00
Received By jgomez Date 2015-07-23 Time 10:57 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-05-21 Cont ID  
Sent By jgomez Date 2015-05-21 Time 11:42 Rev Time 0.00
Received By jgomez Date 2015-05-21 Time 11:42 Sent To  
Notes
2015-05-21 11:46:461- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) FOR IMPACT FEES ASSESSMENT.
 COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND
 DEVELOPMENT CODE.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2015-09-23 Cont ID  
Sent By gomez Date 2015-09-23 Time 18:50 Rev Time 0.00
Received By jgomez Date 2015-09-23 Time 18:50 Sent To  
Notes
2015-09-23 18:51:38SHINGLES NOA 12-1204.03.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2015-07-23 Cont ID  
Sent By jgomez Date 2015-07-23 Time 18:14 Rev Time 0.00
Received By jgomez Date 2015-07-23 Time 18:14 Sent To  
Notes
2015-07-23 18:15:141- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ROOF SHINGLES. NOTE: THERE WERE TWO DIFFERENT
 PRODUCT APPROVALS SUBMITTED. FLORIDA PRODUCT APPROVAL
 FL10124-R14 AND MIAMI-DADE NOA 11-1122.04. CLARIFY
 WHICH ONE IS GOING TO BE USED. ALSO, THERE IS A REVIEW
 STAMP ON THE MIAMI-DADE NOA 11-1122.04. CLARIFY WHO
 REVIEWED AND APPROVED IT.. AND WHY THE DRAWINGS ARE NOT
 SIGNED AND SEALED BY THE SAME PERSON?

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2015-05-21 Cont ID  
Sent By jgomez Date 2015-05-21 Time 11:41 Rev Time 0.00
Received By jgomez Date 2015-05-21 Time 11:41 Sent To  
Notes
2015-05-21 11:42:041- PROVIDE 2 COPIES OF SHINGLES PRODUCT APPROVAL. DC
 RULE 9N-3.

Review Stop Z ZONING
Rev No 3 Status P Date 2015-09-08 Cont ID  
Sent By jgomez Date 2015-09-23 Time 18:53 Rev Time 0.00
Received By sgraham Date 2015-09-08 Time 12:23 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2015-07-10 Cont ID  
Sent By sgraham Date 2015-07-10 Time 16:11 Rev Time 0.00
Received By sgraham Date 2015-07-10 Time 16:11 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-04-10 Cont ID  
Sent By sgraham Date 2015-04-10 Time 10:47 Rev Time 0.00
Received By sgraham Date 2015-04-10 Time 10:47 Sent To B
Notes
2015-04-10 10:48:364/10/15 ZONING FAILED
  
 1. PROVIDE TWO UP TO DATE SURVEYS SHOWING THE LOCATION
 OF NEW SCREEN PORCH.