| Plan Review Stops For Permit 15040128 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-12-09 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-12-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-12-09 |
Time |
05:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-08-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-21 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-21 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-04-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-04-24 |
Time |
15:48 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2015-04-24 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-04-24 15:58:48 | NEW OCCUPANCY TO BE S-2 STORAGE OF METAL SCRAPE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2015-12-21 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-21 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-21 |
Time |
16:26 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2015-09-29 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-29 |
Time |
18:09 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-29 |
Time |
17:48 |
Sent To |
I |
|
| Notes |
| 2015-09-29 18:21:00 | THIS IS THE THIRD TIME THIS PERMITS COMES ACROSS THE | | | ELECTRICAL REVIEWERS DESK WITHOUT HAVING MADE ANY | | | EFFORT TO COMPLY WITH THE MENTIONED | | | REQUIREMENTS/DEFICIENCIES. AS PERMITTED BY FLORIDA | | | STATUTES,(SEE BELOW) THE NEXT TIME THIS COMES ACROSS | | | THIS DESK AND FAILS FOR NOT COMPLYING WITH ANY OF THE | | | PREVIOUSLY MENTIONED COMMENTS A FOUR TIMES THE REGULAR | | | REVIEW FEE WILL BE IMPOSED. | | | FLORIDA STATUTE 553.80(2)(B): WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-09-11 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-11 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-11 |
Time |
11:27 |
Sent To |
I |
|
| Notes |
| 2015-09-11 12:02:10 | THOUGH THIS WAS PREVIOUSLY REVIEWED BY ROBERT LECKY, NO | | | COMMENTS AS TO HIS REVIEW NOR WAS THERE A NARRATIVE | | | ADDRESSING HIS COMMENTS WAS FOUND. I WAS PROMPTED TO | | | CONDUCT A FULL REVIEW OF THE PLANS. | | | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS | | | EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE | | | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO | | | THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE | | | CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW. | | | 1. PER 2010 FBC SECTION 107.1, CONSTRUCTION DOCUMENTS | | | SHALL BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL. | | | 2. PER 2010 FBC SECTION 107.2, CONSTRUCTION DOCUMENTS | | | SHALL BE SUITABLY DIMENSIONED AND BE OF SUFFICIENT | | | CLARITY TO SHOW IN DETAIL THE NATURE AND EXTENT OF THE | | | PROPOSED WORK. | | | 3. PER CITY OF WEST PALM BEACH AMENDMENTS, ALL DRAWINGS | | | SHALL BE DRAWN TO A MINIMUM OF 1/8" SCALE AND BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | 4. YOU SHALL SUBMIT A SITE PLAN, WHICH SHALL INDICATE | | | THE LOCATION OF ALL STRUCTURES ON THE PROPERTY, THE | | | LOCATION OF THE ELECTRICAL SERVICE IN RELATION TO EACH | | | STRUCTURE.. | | | 5. YOU SHALL PROVIDE A SITE SPECIFIC ELECTRICAL RISER | | | DIAGRAM TO INCLUDE THE FEEDERS TO THE VARIOUS | | | STRUCTURES. | | | 6. YOU SHALL PROVIDE ELECTRICAL LOAD CALCS AND A PANEL | | | SCHEDULE FOR EACH STRUCTURE. | | | 7. A PROPERLY DIMENSIONED FLOOR PLAN FOR EACH STRUCTURE | | | INDICATING THE MINIMUM REQUIRED LIGHTING, EMERGENCY | | | LIGHTING AS WELL AS THE REQUIRED EXIT LIGHTING FOR | | | EMERGENCY EGRESS. | | | 8. ALL LIGHTING SHALL COMPLY WITH THE 2010 FBC-ENERGY | | | CONSERVATION CODE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-05-14 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2015-05-14 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2015-05-14 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2015-05-14 14:35:32 | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | ELECTRICAL REVIEW COMMENTS. | | | | | | PROVIDE AN ELECTRICAL PLAN WITH THE FOLLOWING: | | | ELECTRICAL RISER PLAN SHOWING ALL FEEDERS, DISCONNECTS | | | AND PANEL BOARDS | | | LOCATION OF THE ELECTRICAL SERVICE AND MAIN | | | DISCONNECTS | | | LOCATION OF ALL ELECTRICAL PANELBOARDS | | | SAFE WORKING SPACE AT ELECTRICAL DISCONNECTS AND | | | PANELBOARDS | | | EXIT AND EMERGENCY ILLUMINATION | | | | | | PROVIDE ELECTRIC NOTES ON THE PLAN INDICATING THE | | | FOLLOWING: | | | GENERAL PURPOSE RECEPTACLES INSTALLED IN THE | | | BATHROOMS, KITCHENS, ROOFTOPS, OUTDOORS, WITHIN SIX | | | FEET OF SINKS,AT ELECTRIC DRINKING FOUNTAINS, AND | | | VENDING MACHINES ARE GFCI PROTECTED. | | | ALL DISCONNECTS SHALL BE LEGIBLY MARKED TO INDICATE | | | THEIR PURPOSE. | | | | | | CODE REFERENCES: | | | FBC EXISTING BUILDING 908.2, 908.3, 908.4 | | | NEC 110.22, 110.26, 210. 8, 215.5, 422.51, 422.52 | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | 561-373-3701 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2015-11-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-11-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-11-25 |
Time |
09:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-08-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-08-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-08-17 |
Time |
16:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-04-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-04-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-04-27 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2015-04-27 15:03:15 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | GREATER DETAIL IS NEEDED TO DETERMINE OCCUPANCY LIFE | | | SAFETY REQUIREMENTS. | | | | | | ALL NEW OCCUPANCIES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE 5TH EDITION OF FLORIDA FIRE PREVENTION CODE | | | INCLUDING THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND | | | ALL OTHER APPLICABLE CODES OR STANDARDS. | | | | | | COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY/BUILDING | | | SHALL BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, | | | TRAVEL DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END | | | CORRIDORS, EXIT SIGNS, EMERGENCY LIGHTING, EXITS | | | LEADING TO A PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, | | | AND ALL FIRE SAFETY FEATURES AND EQUIPMENT. | | | | | | PROVIDE ALL LIFE SAFETY ENGINEERED EQUIPMENT FOR EACH | | | BUILDING, I.E FIRE ALARM, FIRE SPRINKLER, FIRE | | | SUPPRESSION SYSTEMS, ETC. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
P |
Date |
2016-01-26 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2016-01-26 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2016-01-26 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2016-01-26 09:11:38 | BASED ON FIELD INSPECTION BY FIRE AND BUILDING, THIS IS | | | NOT A CHANGE OF USE OR CHANGE OF OCCUPANCE. IT IS A | | | CHANGE OF THE BUSINESS NAME. THE EXISTING OFFICE AND | | | WAREHOUSE WILL BE USED FOR THE SAME PURPOSES AS | | | PREVIOUSLY USED, OFFICE AND WAREHOUSE. THE ONLY CHANGE | | | WILL BE FROM WAREHOUSING MARBLE TO WAREHOUSING SCRAP | | | METAL, BOT NON-COMBUSTIBLE. NO PLAN REVIEW CHANGES ARE | | | REQUIRED AND THE NO REVISED CERTIFICATE OF OCCUPANCY IS | | | NEEDED. WHAT IS NEEDED IS A NEW BUSINESS TAX RECEIPT | | | AND TO ADVISE THE TENANT OF THE HOLD ON THE PROEPTY | | | FROM FINANCE. DOUG HARVEY - 1/26/15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-12-21 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-21 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-11-23 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2015-12-21 18:24:41 | 12/21/15 PASSED ELECTRICAL REVIEW. OWNER NOTIFIED VIA | | | EMAIL. SENT TO SMALL READY BIN "T". MA | | 2015-11-24 09:08:09 | B01 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-09-29 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-29 |
Time |
18:32 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-22 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2015-09-29 18:34:49 | 9/29/15 FAILED ELECTRICAL REVIEW FOR THE SAME THING A | | | THIRD TIME. ISSUED WARNING OF 4 X'S FEE TO JOHN VIA | | | EMAIL AND IN PLAN REVIEW NOTES. SENT TO SMALL DENIED | | | BIN "TBS". MA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-09-11 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-11 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-08-12 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2015-09-11 12:07:23 | 9/11/15 - FAILED ELECTRICAL REVIEW. ATTEMPTED TO | | | CONTACT JOHN CARUSO BUT HIS MAILBOX WAS FULL. SENT TO | | | SMALL DENIED BIN "R". MA | | 2015-08-12 15:22:33 | B05 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-05-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-22 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-03 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2015-08-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-21 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-21 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2015-08-21 13:26:12 | PLANS BACK FROM P. B. COUNTY IMPACT FEE ASSESSMENT, NO | | | FEES DUE STAMP. 06/04/2015 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2015-06-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-06-04 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-06-04 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2015-06-04 15:00:40 | PLANS BACK FROM P. B. COUNTY IMPACT FEE ASSESSMENT, NO | | | FEES DUE STAMP. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-04-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-04-24 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-04-24 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2015-04-24 16:03:42 | NOTE I'VE SPOKEN WITH PALM BEACH COUNTY IMPACT FEE | | | ADMINISTRATOR WILLIE SCWOOPE. MR. SCWOOPE BELIEVES | | | THERE WILL BE NO IMPACT FEES ASSESSED BUT SINCE THERE | | | IS A CHANGE OF OCCUPANCY AND TO UPDATE THEIR RECORDS | | | THEY WOULD PERFER THE PLANS TO BE SUBMITTED TO PLAM | | | PEACH COUNTY IMPACT FEE OFFICE FOR REVIEW. | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE REVIEWED BY PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2015-08-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-08-20 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-08-19 |
Time |
17:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-05-19 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-04-24 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2015-05-19 14:02:22 | 1ST. MECHANICAL REVIEW | | | WPB AMENDMENTS TO FBC-10 BUILDING. | | | | | | 1) PURSUANT TO SECTION 909.1 FBC-10 EXISTING BUILDING | | | CODE, PROVIDE VENTILATION CALCULATIONS FOR THE NEW | | | TENANT BUILDINGS PER TABLE 404.3 FMC-10. | | | DUE TO THE CHANGE IN USE, VERIFICATION THAT THE | | | EXISTING AC AND EXHAUST SYSTEMS ARE ADEQUATELY SIZED | | | FOR THE NEW OPERATIONS IS REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2015-12-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-12-01 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-12-01 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2015-09-23 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-29 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-09-23 |
Time |
06:32 |
Sent To |
|
|
| Notes |
| 2015-09-23 05:01:24 | 1) THERE IS A CLOUDED NOTE IN THE CENTER OF THE PLAN | | | THAT NOTES AN S-2 OCCUPANCY WITH A TOTAL OF 143 | | | OCCUPANTS. WHERE IS THIS NUMBER COMING FROM AND WHAT IS | | | THE S-2 OCCUPANCY REFERRING TO, ALL THE STORAGE | | | BUILDINGS? THIS NOTE IS EXTREMELY VAGUE AS TO WHAT & | | | WHERE IT APPLIES.CLARIFY. | | | 2) THE OCCUPANT LOAD FOR STORAGE BUILDING #5 IS SHOWN | | | AS 67 & 69 OCCUPANTS. WHICH IS IT? CLARIFY. | | | 3) THE REQUIRED SANITARY FACILITIES SHALL BE EVALUATED | | | FOR EACH BUILDING, NOT ADDED TOGETHER AS IT APPEARS IS | | | BEING ATTEMPTED FOR THE STORAGE OCCUPANCIES. CLARIFY. | | | 4) THE DRINKING FOUNTAINS AND THE ACCESSIBLE RESTROOMS | | | SHALL BE ON AN ACCESSIBLE ROUTE. THE PLANS DO NOT | | | CLEARLY SHOW THIS. THE ACCESSIBLE ROUTE SHALL COMPLY | | | WITH THE FBC-ACCESSIBILITY SECS.206.1, 206.2.2, | | | 206.4,302,303, 402.2, 403. | | | 5) PLEASE PLACE THE ADDRESS OF THE BUILDINGS ON THE | | | PLANS.WPB AMEND. TO FBC SEC.107.2.1. | | | | | | THE FOLLOWING INFORMATION IS PROVIDED IN THE EVENT THAT | | | SANITARY FACILITIES ARE ADDED TO ANY OF THE BUILDINGS | | | AT A LATER DATE. | | | | | | BLDG. #1 - BUSINESS OCCUPANCY - 49 OCCUPANTS -PER TABLE | | | 403.1 - | | | DRINKING FOUNTAIN- 2 REQUIRED PER TABLE 403.1 FOOTNOTE | | | (E) & FBC-ACCESSIBILITY SEC.211.2. | | | MALES (COMPLIES) | | | WATER CLOSET- 1 | | | LAVATORY- 1 | | | FEMALES (COMPLIES) | | | WATER CLOSET- 1 | | | LAVATORY - 1 | | | | | | BLDG.# 2 - STORAGE OCCUPANCY - 17 OCCUPANTS - PER TABLE | | | 403.1 | | | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE | | | (E) & FBC-ACCESSIBILITY SEC.211.2. | | | WATER CLOSETS - 1 | | | LAVATORIES - 1 | | | SERVICE SINK - 1 | | | | | | BLDG.# 3 - STORAGE OCCUPANCY - 2 OCCUPANTS - PER TABLE | | | 403.1 | | | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE | | | (E) & FBC-ACCESSIBILITY SEC.211.2. | | | SERVICE SINK - 1 | | | WATER CLOSET - 1 | | | LAVATORY - 1 | | | | | | BLDG.# 4 - STORAGE OCCUPANCY - 8 OCCCUPANTS - PER TABLE | | | 403.1 | | | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE | | | (E) & FBC-ACCESSIBILITY SEC.211.2. | | | SERVICE SINK - 1 | | | WATER CLOSET - 1 | | | LAVATORY - 1 | | | | | | BLDG.# 5 - STORAGE OCCUPANCY - 67 OCCCUPANTS - PER | | | TABLE 403.1 | | | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE | | | (E) & FBC-ACCESSIBILITY SEC.211.2. | | | SERVICE SINK - 1 | | | WATER CLOSET - 1 | | | LAVATORY - 1 | | | | | | | | | I SUGGEST CONTACTING ME TO SET UP AN APPOINTMENT TO | | | DISCUSS THESE COMMENTS. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2015-08-31 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-08-31 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-08-24 |
Time |
04:43 |
Sent To |
|
|
| Notes |
| 2015-08-24 06:57:33 | 1) SUBMIT INFORMATION AS TO THE NUMBER AND TYPE OF | | | SANITARY FACILITIES THAT ARE CURRENTLY LOCATED IN EACH | | | BUILDING AND THE NUMBER OF TOILET ROOMS IN EACH | | | FACILITY.THIS HAS NOT BEEN DONE IN COMPLIANCE WITH THE | | | FBC-PLUMBING TABLE 403.1. | | | BLDG. #1 - BUSINESS OCCUPANCY - 49 OCCUPANTS -PER TABLE | | | 403.1 - | | | DRINKING FOUNTAIN- 2 REQUIRED PER TABLE 403.1 FOOTNOTE | | | (E) & FBC-ACCESSIBILITY SEC.211.2. | | | MALES | | | WATER CLOSET- 1 | | | LAVATORY- 1 | | | FEMALES | | | WATER CLOSET- 1 | | | LAVATORY - 1 | | | | | | BLDG.# 2 - STORAGE OCCUPANCY - 17 OCCUPANTS - PER TABLE | | | 403.1 | | | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE | | | (E) & FBC-ACCESSIBILITY SEC.211.2. | | | WATER CLOSETS - 1 | | | LAVATORIES - 1 | | | SERVICE SINK - 1 | | | | | | BLDG.# 3 - STORAGE OCCUPANCY - 2 OCCUPANTS - PER TABLE | | | 403.1 | | | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE | | | (E) & FBC-ACCESSIBILITY SEC.211.2. | | | SERVICE SINK - 1 | | | WATER CLOSET - 1 | | | LAVATORY - 1 | | | | | | BLDG.# 4 - STORAGE OCCUPANCY - 8 OCCCUPANTS - PER TABLE | | | 403.1 | | | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE | | | (E) & FBC-ACCESSIBILITY SEC.211.2. | | | SERVICE SINK - 1 | | | WATER CLOSET - 1 | | | LAVATORY - 1 | | | | | | BLDG.# 5 - STORAGE OCCUPANCY - 67 OCCCUPANTS - PER | | | TABLE 403.1 | | | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE | | | (E) & FBC-ACCESSIBILITY SEC.211.2. | | | SERVICE SINK - 1 | | | WATER CLOSET - 1 | | | LAVATORY - 1 | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-04-27 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-04-27 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-04-27 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2015-04-27 10:28:19 | SUBMIT INFORMATION AS TO THE NUMBER AND TYPE OF | | | SANITARY FACILITIES THAT ARE CURRENTLY LOCATED IN EACH | | | BUILDING AND THE NUMBER OF RESTROOM FACILITIES IN EACH | | | BUILDING. 2010 FPC TABLE 403.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-12-15 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-12-15 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-12-14 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-08-27 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-08-27 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-08-27 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-04-28 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-04-28 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-04-28 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2015-04-28 13:30:54 | PURSUANT TO SECTION 94-444(C) OF THE CITY'S ZONING AND | | | LAND DEVELOPMENT REGULATIONS, OUTDOOR STORAGE SHALL NOT | | | BE PERMITTED UNLESS ENCLOSED ON ALL SIDES BY A WALL OF | | | ADEQUATE HEIGHT CONSTRUCTED OF BRICK, DECORATIVE | | | CONCRETE, OTHER DECORATIVE MASONRY, OR COMPARABLY | | | DURABLE WOOD OR STEEL. WALL OPENINGS SHALL HAVE | | | OBSCURING GATES. ALL AREAS FOR THE STORAGE AND DISPOSAL | | | OF GOODS, MERCHANDISE, AND MATERIALS SHALL BE COVERED | | | WITH EITHER ASPHALT OR CONCRETE PAVING, OR CRUSHED ROCK | | | OF SUCH SPECIFICATION AND DESIGN AS REQUIRED BY THE | | | ENGINEERING DEPARTMENT. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL | | | PLANNER, AT (561) 822-1448 OR VIA EMAIL AT | | | [email protected] |
|
|