Plan Review Details - Permit 15040128
Plan Review Stops For Permit 15040128
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-12-09 Cont ID  
Sent By   Date 2015-12-09 Time   Rev Time 0.00
Received By jwitmer Date 2015-12-09 Time 05:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-08-21 Cont ID  
Sent By jwitmer Date 2015-08-21 Time 13:26 Rev Time 0.00
Received By jwitmer Date 2015-08-21 Time 13:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-04-24 Cont ID  
Sent By jwitmer Date 2015-04-24 Time 15:48 Rev Time  
Received By jwitmer Date 2015-04-24 Time   Sent To  
Notes
2015-04-24 15:58:48NEW OCCUPANCY TO BE S-2 STORAGE OF METAL SCRAPE.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2015-12-21 Cont ID  
Sent By albarran Date 2015-12-21 Time 18:20 Rev Time 0.00
Received By albarran Date 2015-12-21 Time 16:26 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2015-09-29 Cont ID  
Sent By albarran Date 2015-09-29 Time 18:09 Rev Time 0.00
Received By albarran Date 2015-09-29 Time 17:48 Sent To I
Notes
2015-09-29 18:21:00THIS IS THE THIRD TIME THIS PERMITS COMES ACROSS THE
 ELECTRICAL REVIEWERS DESK WITHOUT HAVING MADE ANY
 EFFORT TO COMPLY WITH THE MENTIONED
 REQUIREMENTS/DEFICIENCIES. AS PERMITTED BY FLORIDA
 STATUTES,(SEE BELOW) THE NEXT TIME THIS COMES ACROSS
 THIS DESK AND FAILS FOR NOT COMPLYING WITH ANY OF THE
 PREVIOUSLY MENTIONED COMMENTS A FOUR TIMES THE REGULAR
 REVIEW FEE WILL BE IMPOSED.
 FLORIDA STATUTE 553.80(2)(B): WITH RESPECT TO
 EVALUATION OF DESIGN PROFESSIONALS DOCUMENTS, IF A
 LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO
 ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND
 ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY
 THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A
 CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN
 EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS,
 FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-09-11 Cont ID  
Sent By albarran Date 2015-09-11 Time 11:58 Rev Time 0.00
Received By albarran Date 2015-09-11 Time 11:27 Sent To I
Notes
2015-09-11 12:02:10THOUGH THIS WAS PREVIOUSLY REVIEWED BY ROBERT LECKY, NO
 COMMENTS AS TO HIS REVIEW NOR WAS THERE A NARRATIVE
 ADDRESSING HIS COMMENTS WAS FOUND. I WAS PROMPTED TO
 CONDUCT A FULL REVIEW OF THE PLANS.
 PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS
 EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE
 MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO
 THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE
 CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW.
 1. PER 2010 FBC SECTION 107.1, CONSTRUCTION DOCUMENTS
 SHALL BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL.
 2. PER 2010 FBC SECTION 107.2, CONSTRUCTION DOCUMENTS
 SHALL BE SUITABLY DIMENSIONED AND BE OF SUFFICIENT
 CLARITY TO SHOW IN DETAIL THE NATURE AND EXTENT OF THE
 PROPOSED WORK.
 3. PER CITY OF WEST PALM BEACH AMENDMENTS, ALL DRAWINGS
 SHALL BE DRAWN TO A MINIMUM OF 1/8" SCALE AND BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN.
 4. YOU SHALL SUBMIT A SITE PLAN, WHICH SHALL INDICATE
 THE LOCATION OF ALL STRUCTURES ON THE PROPERTY, THE
 LOCATION OF THE ELECTRICAL SERVICE IN RELATION TO EACH
 STRUCTURE..
 5. YOU SHALL PROVIDE A SITE SPECIFIC ELECTRICAL RISER
 DIAGRAM TO INCLUDE THE FEEDERS TO THE VARIOUS
 STRUCTURES.
 6. YOU SHALL PROVIDE ELECTRICAL LOAD CALCS AND A PANEL
 SCHEDULE FOR EACH STRUCTURE.
 7. A PROPERLY DIMENSIONED FLOOR PLAN FOR EACH STRUCTURE
 INDICATING THE MINIMUM REQUIRED LIGHTING, EMERGENCY
 LIGHTING AS WELL AS THE REQUIRED EXIT LIGHTING FOR
 EMERGENCY EGRESS.
 8. ALL LIGHTING SHALL COMPLY WITH THE 2010 FBC-ENERGY
 CONSERVATION CODE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-05-14 Cont ID  
Sent By rlecky Date 2015-05-14 Time 14:34 Rev Time 0.00
Received By rlecky Date 2015-05-14 Time 13:27 Sent To  
Notes
2015-05-14 14:35:32PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 ELECTRICAL REVIEW COMMENTS.
  
 PROVIDE AN ELECTRICAL PLAN WITH THE FOLLOWING:
  ELECTRICAL RISER PLAN SHOWING ALL FEEDERS, DISCONNECTS
 AND PANEL BOARDS
  LOCATION OF THE ELECTRICAL SERVICE AND MAIN
 DISCONNECTS
  LOCATION OF ALL ELECTRICAL PANELBOARDS
 SAFE WORKING SPACE AT ELECTRICAL DISCONNECTS AND
 PANELBOARDS
  EXIT AND EMERGENCY ILLUMINATION
  
 PROVIDE ELECTRIC NOTES ON THE PLAN INDICATING THE
 FOLLOWING:
  GENERAL PURPOSE RECEPTACLES INSTALLED IN THE
 BATHROOMS, KITCHENS, ROOFTOPS, OUTDOORS, WITHIN SIX
 FEET OF SINKS,AT ELECTRIC DRINKING FOUNTAINS, AND
 VENDING MACHINES ARE GFCI PROTECTED.
  ALL DISCONNECTS SHALL BE LEGIBLY MARKED TO INDICATE
 THEIR PURPOSE.
  
 CODE REFERENCES:
  FBC EXISTING BUILDING 908.2, 908.3, 908.4
  NEC 110.22, 110.26, 210. 8, 215.5, 422.51, 422.52
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 561-373-3701
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2015-11-25 Cont ID  
Sent By pleduc Date 2015-11-25 Time   Rev Time 0.00
Received By pleduc Date 2015-11-25 Time 09:42 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-08-17 Cont ID  
Sent By pleduc Date 2015-08-17 Time   Rev Time 0.00
Received By pleduc Date 2015-08-17 Time 16:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-04-27 Cont ID  
Sent By pleduc Date 2015-04-27 Time   Rev Time 0.00
Received By pleduc Date 2015-04-27 Time 14:51 Sent To  
Notes
2015-04-27 15:03:15THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 GREATER DETAIL IS NEEDED TO DETERMINE OCCUPANCY LIFE
 SAFETY REQUIREMENTS.
  
 ALL NEW OCCUPANCIES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE 5TH EDITION OF FLORIDA FIRE PREVENTION CODE
 INCLUDING THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND
 ALL OTHER APPLICABLE CODES OR STANDARDS.
  
 COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY/BUILDING
 SHALL BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS,
 TRAVEL DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END
 CORRIDORS, EXIT SIGNS, EMERGENCY LIGHTING, EXITS
 LEADING TO A PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS,
 AND ALL FIRE SAFETY FEATURES AND EQUIPMENT.
  
 PROVIDE ALL LIFE SAFETY ENGINEERED EQUIPMENT FOR EACH
 BUILDING, I.E FIRE ALARM, FIRE SPRINKLER, FIRE
 SUPPRESSION SYSTEMS, ETC.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status P Date 2016-01-26 Cont ID  
Sent By dharvey Date 2016-01-26 Time 09:11 Rev Time 0.00
Received By dharvey Date 2016-01-26 Time 09:08 Sent To  
Notes
2016-01-26 09:11:38BASED ON FIELD INSPECTION BY FIRE AND BUILDING, THIS IS
 NOT A CHANGE OF USE OR CHANGE OF OCCUPANCE. IT IS A
 CHANGE OF THE BUSINESS NAME. THE EXISTING OFFICE AND
 WAREHOUSE WILL BE USED FOR THE SAME PURPOSES AS
 PREVIOUSLY USED, OFFICE AND WAREHOUSE. THE ONLY CHANGE
 WILL BE FROM WAREHOUSING MARBLE TO WAREHOUSING SCRAP
 METAL, BOT NON-COMBUSTIBLE. NO PLAN REVIEW CHANGES ARE
 REQUIRED AND THE NO REVISED CERTIFICATE OF OCCUPANCY IS
 NEEDED. WHAT IS NEEDED IS A NEW BUSINESS TAX RECEIPT
 AND TO ADVISE THE TENANT OF THE HOLD ON THE PROEPTY
 FROM FINANCE. DOUG HARVEY - 1/26/15

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-12-21 Cont ID  
Sent By albarran Date 2015-12-21 Time 18:20 Rev Time 0.00
Received By albarran Date 2015-11-23 Time 09:07 Sent To  
Notes
2015-12-21 18:24:4112/21/15 PASSED ELECTRICAL REVIEW. OWNER NOTIFIED VIA
 EMAIL. SENT TO SMALL READY BIN "T". MA
2015-11-24 09:08:09B01

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-09-29 Cont ID  
Sent By albarran Date 2015-09-29 Time 18:32 Rev Time 0.00
Received By albarran Date 2015-09-22 Time 16:08 Sent To  
Notes
2015-09-29 18:34:499/29/15 FAILED ELECTRICAL REVIEW FOR THE SAME THING A
 THIRD TIME. ISSUED WARNING OF 4 X'S FEE TO JOHN VIA
 EMAIL AND IN PLAN REVIEW NOTES. SENT TO SMALL DENIED
 BIN "TBS". MA

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-09-11 Cont ID  
Sent By albarran Date 2015-09-11 Time 12:03 Rev Time 0.00
Received By albarran Date 2015-08-12 Time 15:22 Sent To  
Notes
2015-09-11 12:07:239/11/15 - FAILED ELECTRICAL REVIEW. ATTEMPTED TO
 CONTACT JOHN CARUSO BUT HIS MAILBOX WAS FULL. SENT TO
 SMALL DENIED BIN "R". MA
2015-08-12 15:22:33B05

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-05-22 Cont ID  
Sent By rmcdouga Date 2015-05-22 Time 17:19 Rev Time 0.00
Received By rmcdouga Date 2015-04-03 Time 09:40 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2015-08-21 Cont ID  
Sent By jwitmer Date 2015-08-21 Time 13:25 Rev Time 0.00
Received By jwitmer Date 2015-08-21 Time 13:25 Sent To  
Notes
2015-08-21 13:26:12PLANS BACK FROM P. B. COUNTY IMPACT FEE ASSESSMENT, NO
 FEES DUE STAMP. 06/04/2015

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2015-06-04 Cont ID  
Sent By jwitmer Date 2015-06-04 Time 14:59 Rev Time 0.00
Received By jwitmer Date 2015-06-04 Time 14:59 Sent To  
Notes
2015-06-04 15:00:40PLANS BACK FROM P. B. COUNTY IMPACT FEE ASSESSMENT, NO
 FEES DUE STAMP.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-04-24 Cont ID  
Sent By jwitmer Date 2015-04-24 Time 15:58 Rev Time 0.00
Received By jwitmer Date 2015-04-24 Time 15:58 Sent To  
Notes
2015-04-24 16:03:42NOTE I'VE SPOKEN WITH PALM BEACH COUNTY IMPACT FEE
 ADMINISTRATOR WILLIE SCWOOPE. MR. SCWOOPE BELIEVES
 THERE WILL BE NO IMPACT FEES ASSESSED BUT SINCE THERE
 IS A CHANGE OF OCCUPANCY AND TO UPDATE THEIR RECORDS
 THEY WOULD PERFER THE PLANS TO BE SUBMITTED TO PLAM
 PEACH COUNTY IMPACT FEE OFFICE FOR REVIEW.
  
 BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE REVIEWED BY PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2015-08-20 Cont ID  
Sent By ccole Date 2015-08-20 Time 07:10 Rev Time 0.00
Received By ccole Date 2015-08-19 Time 17:17 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-05-19 Cont ID  
Sent By ccole Date 2015-05-19 Time 13:49 Rev Time 0.00
Received By ccole Date 2015-04-24 Time 13:49 Sent To  
Notes
2015-05-19 14:02:221ST. MECHANICAL REVIEW
 WPB AMENDMENTS TO FBC-10 BUILDING.
  
 1) PURSUANT TO SECTION 909.1 FBC-10 EXISTING BUILDING
 CODE, PROVIDE VENTILATION CALCULATIONS FOR THE NEW
 TENANT BUILDINGS PER TABLE 404.3 FMC-10.
 DUE TO THE CHANGE IN USE, VERIFICATION THAT THE
 EXISTING AC AND EXHAUST SYSTEMS ARE ADEQUATELY SIZED
 FOR THE NEW OPERATIONS IS REQUIRED.

Review Stop P PLUMBING
Rev No 4 Status P Date 2015-12-01 Cont ID  
Sent By tklarge Date 2015-12-01 Time 11:08 Rev Time 0.00
Received By tklarge Date 2015-12-01 Time 10:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2015-09-23 Cont ID  
Sent By albarran Date 2015-09-29 Time 18:34 Rev Time 0.00
Received By tklarge Date 2015-09-23 Time 06:32 Sent To  
Notes
2015-09-23 05:01:241) THERE IS A CLOUDED NOTE IN THE CENTER OF THE PLAN
 THAT NOTES AN S-2 OCCUPANCY WITH A TOTAL OF 143
 OCCUPANTS. WHERE IS THIS NUMBER COMING FROM AND WHAT IS
 THE S-2 OCCUPANCY REFERRING TO, ALL THE STORAGE
 BUILDINGS? THIS NOTE IS EXTREMELY VAGUE AS TO WHAT &
 WHERE IT APPLIES.CLARIFY.
 2) THE OCCUPANT LOAD FOR STORAGE BUILDING #5 IS SHOWN
 AS 67 & 69 OCCUPANTS. WHICH IS IT? CLARIFY.
 3) THE REQUIRED SANITARY FACILITIES SHALL BE EVALUATED
 FOR EACH BUILDING, NOT ADDED TOGETHER AS IT APPEARS IS
 BEING ATTEMPTED FOR THE STORAGE OCCUPANCIES. CLARIFY.
 4) THE DRINKING FOUNTAINS AND THE ACCESSIBLE RESTROOMS
 SHALL BE ON AN ACCESSIBLE ROUTE. THE PLANS DO NOT
 CLEARLY SHOW THIS. THE ACCESSIBLE ROUTE SHALL COMPLY
 WITH THE FBC-ACCESSIBILITY SECS.206.1, 206.2.2,
 206.4,302,303, 402.2, 403.
 5) PLEASE PLACE THE ADDRESS OF THE BUILDINGS ON THE
 PLANS.WPB AMEND. TO FBC SEC.107.2.1.
  
 THE FOLLOWING INFORMATION IS PROVIDED IN THE EVENT THAT
 SANITARY FACILITIES ARE ADDED TO ANY OF THE BUILDINGS
 AT A LATER DATE.
  
 BLDG. #1 - BUSINESS OCCUPANCY - 49 OCCUPANTS -PER TABLE
 403.1 -
 DRINKING FOUNTAIN- 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 MALES (COMPLIES)
 WATER CLOSET- 1
 LAVATORY- 1
 FEMALES (COMPLIES)
 WATER CLOSET- 1
 LAVATORY - 1
  
 BLDG.# 2 - STORAGE OCCUPANCY - 17 OCCUPANTS - PER TABLE
 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 WATER CLOSETS - 1
 LAVATORIES - 1
 SERVICE SINK - 1
  
 BLDG.# 3 - STORAGE OCCUPANCY - 2 OCCUPANTS - PER TABLE
 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 SERVICE SINK - 1
 WATER CLOSET - 1
 LAVATORY - 1
  
 BLDG.# 4 - STORAGE OCCUPANCY - 8 OCCCUPANTS - PER TABLE
 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 SERVICE SINK - 1
 WATER CLOSET - 1
 LAVATORY - 1
  
 BLDG.# 5 - STORAGE OCCUPANCY - 67 OCCCUPANTS - PER
 TABLE 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 SERVICE SINK - 1
 WATER CLOSET - 1
 LAVATORY - 1
  
  
 I SUGGEST CONTACTING ME TO SET UP AN APPOINTMENT TO
 DISCUSS THESE COMMENTS.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-08-31 Cont ID  
Sent By tklarge Date 2015-08-31 Time 14:55 Rev Time 0.00
Received By tklarge Date 2015-08-24 Time 04:43 Sent To  
Notes
2015-08-24 06:57:331) SUBMIT INFORMATION AS TO THE NUMBER AND TYPE OF
 SANITARY FACILITIES THAT ARE CURRENTLY LOCATED IN EACH
 BUILDING AND THE NUMBER OF TOILET ROOMS IN EACH
 FACILITY.THIS HAS NOT BEEN DONE IN COMPLIANCE WITH THE
 FBC-PLUMBING TABLE 403.1.
 BLDG. #1 - BUSINESS OCCUPANCY - 49 OCCUPANTS -PER TABLE
 403.1 -
 DRINKING FOUNTAIN- 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 MALES
 WATER CLOSET- 1
 LAVATORY- 1
 FEMALES
 WATER CLOSET- 1
 LAVATORY - 1
  
 BLDG.# 2 - STORAGE OCCUPANCY - 17 OCCUPANTS - PER TABLE
 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 WATER CLOSETS - 1
 LAVATORIES - 1
 SERVICE SINK - 1
  
 BLDG.# 3 - STORAGE OCCUPANCY - 2 OCCUPANTS - PER TABLE
 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 SERVICE SINK - 1
 WATER CLOSET - 1
 LAVATORY - 1
  
 BLDG.# 4 - STORAGE OCCUPANCY - 8 OCCCUPANTS - PER TABLE
 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 SERVICE SINK - 1
 WATER CLOSET - 1
 LAVATORY - 1
  
 BLDG.# 5 - STORAGE OCCUPANCY - 67 OCCCUPANTS - PER
 TABLE 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 SERVICE SINK - 1
 WATER CLOSET - 1
 LAVATORY - 1
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  
  
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-04-27 Cont ID  
Sent By tklarge Date 2015-04-27 Time 10:28 Rev Time 0.00
Received By tklarge Date 2015-04-27 Time 09:52 Sent To  
Notes
2015-04-27 10:28:19SUBMIT INFORMATION AS TO THE NUMBER AND TYPE OF
 SANITARY FACILITIES THAT ARE CURRENTLY LOCATED IN EACH
 BUILDING AND THE NUMBER OF RESTROOM FACILITIES IN EACH
 BUILDING. 2010 FPC TABLE 403.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2015-12-15 Cont ID  
Sent By jroach Date 2015-12-15 Time 08:24 Rev Time 0.00
Received By jroach Date 2015-12-14 Time 16:58 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2015-08-27 Cont ID  
Sent By jroach Date 2015-08-27 Time 15:51 Rev Time 0.00
Received By jroach Date 2015-08-27 Time 15:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-04-28 Cont ID  
Sent By jroach Date 2015-04-28 Time 13:30 Rev Time 0.00
Received By jroach Date 2015-04-28 Time 13:30 Sent To  
Notes
2015-04-28 13:30:54PURSUANT TO SECTION 94-444(C) OF THE CITY'S ZONING AND
 LAND DEVELOPMENT REGULATIONS, OUTDOOR STORAGE SHALL NOT
 BE PERMITTED UNLESS ENCLOSED ON ALL SIDES BY A WALL OF
 ADEQUATE HEIGHT CONSTRUCTED OF BRICK, DECORATIVE
 CONCRETE, OTHER DECORATIVE MASONRY, OR COMPARABLY
 DURABLE WOOD OR STEEL. WALL OPENINGS SHALL HAVE
 OBSCURING GATES. ALL AREAS FOR THE STORAGE AND DISPOSAL
 OF GOODS, MERCHANDISE, AND MATERIALS SHALL BE COVERED
 WITH EITHER ASPHALT OR CONCRETE PAVING, OR CRUSHED ROCK
 OF SUCH SPECIFICATION AND DESIGN AS REQUIRED BY THE
 ENGINEERING DEPARTMENT.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL
 PLANNER, AT (561) 822-1448 OR VIA EMAIL AT
 [email protected]