Plan Review Details - Permit 15040122
Plan Review Stops For Permit 15040122
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-06-12 Cont ID  
Sent By JWITMER Date 2015-06-10 Time 07:23 Rev Time 0.00
Received By jwitmer Date 2015-06-10 Time 07:02 Sent To  
Notes
2015-06-10 07:23:00BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15040122
 ADD: 525 S. FLAGLER DR. SUITE # 29A/B
 CONT: R & D CONSTRUCTORS
 TEL: (561)889-1751
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: FRI. JUNE 12/ 2015
 ACTION: PROVISO
  
 1) RED LINED!!!! SHEET A-101.00 DOOR SCHEDULE, DOORS
 D02 & D03 INDICATE THEY ARE BOTH 2'-6" DOORS. UNDER THE
 2010 FBC-B1008.1.1 THE MINIMUM SIZE SHALL BE 32 INCHES
 CLEAR WIDH, MINIMUM SIZE FOR A SWING DOOR IS 2 FT 10
 INCHES, EXCEPTION # 1 THE MINIMUM AND MAXIMUM WIDTH
 SHALL NOT APPLY TO DOOR OPENINGS THAT ARE NOT PART OF
 THE REQUIRED MEANS OF EGRESS IN GROUP R-2 AND R-3
 OCCUPANCIES. THESE DOORS ARE PART OF THE MEANS OF
 EGRESS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-04-24 Cont ID  
Sent By jwitmer Date 2015-04-24 Time 06:32 Rev Time 0.00
Received By jwitmer Date 2015-04-24 Time 06:00 Sent To  
Notes
2015-04-24 06:36:07BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15040122
 ADD: 525 S. FLAGLER DR. SUITE # 29A/B
 CONT: R & D CONSTRUCTORS
 TEL: (561)889-1751
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE.
  
 1ST REVIEW
 DATE: FRI. APRIL 24/ 2015
 ACTION: DENIED
  
 1) THERE IS NO CODE ANALYSIS FOR THE PROJECT THE PLANS
 DO NOT DECLARE TO WHICH CODE THE PLANS WERE DEVELOPED
 UNDER THE 2010 FL. EXISSTING BUILDING CODE SECTION
 101.5 THE DESIGN PROFESSIONAL NEEDS TO PROVIDE WHICH
 COMPLIANCE METHOD THE PLANS WERE DESIGNED.
  
 2) SHEET A-101.00 DOOR SCHEDULE, DOORS D02 & D03
 INDICATE THEY ARE BOTH 2'-6" DOORS. UNDER THE 2010
 FBC-B THE MINIMUM SIZE SHALL BE 32 INCHES, EXCEPTION #
 1 THE MINIMUM AND MAXIMUM WIDTH SHALL NOT APPLY TO DOOR
 OPENINGS THAT ARE NOT PART OF THE REQUIRED MEANS OF
 EGRESS IN GROUP R-2 AND R-3 OCCUPANCIES.
 THESE DOORS ARE PART OF THE MEANS OF EGRESS.
  
 MEANS OF EGRESS. A CONTINUOUS AND UNOBSTRUCTED PATH OF
 VERTICAL AND HORIZONTAL EGRESS TRAVEL FROM ANY OCCUPIED
 PORTION OF A BUILDING OR STRUCTURE TO A PUBLIC WAY. A
 MEANS OF EGRESS CONSISTS OF THREE SEPARATE AND DISTINCT
 PARTS: THE EXIT ACCESS, THE EXIT AND THE EXIT
 DISCHARGE.
  
 EXIT ACCESS. THAT PORTION OF A MEANS OF EGRESS SYSTEM
 THAT LEADS FROM ANY OCCUPIED PORTION OF A BUILDING OR
 STRUCTURE TO AN EXIT.
  
 EXIT ACCESS DOORWAY. A DOOR OR ACCESS POINT ALONG THE
 PATH OF EGRESS TRAVEL FROM AN OCCUPIED ROOM, AREA OR
 SPACE WHERE THE PATH OF EGRESS ENTERS AN INTERVENING
 ROOM, CORRIDOR, UNENCLOSED EXIT ACCESS STAIR OR
 UNENCLOSED EXIT ACCESS RAMP.
  
 3) SUBMITTED IS SPECIFICATIONS TO USE QUIET CORK FLOOR
 SOUND INSULATION. PLEASE SUBMIT THE FOLLOWING DOCUMENTS
 FOR CODE COMPLIANCE:
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION
  
 3A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 3B) FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 3C) FLAME SPREAD- FBC-B 2010 603.1.2 EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 703.4 NONCOMBUSTIBILITY TESTS.
 THE TESTS INDICATED IN SECTIONS 703.4.1 AND 703.4.2
 SHALL SERVE AS CRITERIA FOR ACCEPTANCE OF BUILDING
 MATERIALS AS SET FORTH IN SECTIONS 602.2, 602.3 AND
 602.4 IN TYPE I, II, III AND IV CONSTRUCTION. THE TERM
 ?NONCOMBUSTIBLE? DOES NOT APPLY TO THE FLAME SPREAD
 CHARACTERISTICS OF INTERIOR FINISH OR TRIM MATERIALS. A
 MATERIAL SHALL NOT BE CLASSIFIED AS A NONCOMBUSTIBLE
 BUILDING CONSTRUCTION MATERIAL IF IT IS SUBJECT TO AN
 INCREASE IN COMBUSTIBILITY OR FLAME SPREAD BEYOND THE
 LIMITATIONS HEREIN ESTABLISHED THROUGH THE EFFECTS OF
 AGE, MOISTURE OR OTHER ATMOSPHERIC CONDITIONS.
  
 703.4.1 ELEMENTARY MATERIALS.
 MATERIALS REQUIRED TO BE NONCOMBUSTIBLE SHALL BE TESTED
 IN ACCORDANCE WITH ASTM E 136.
  
 703.4.2 COMPOSITE MATERIALS.
 MATERIALS HAVING A STRUCTURAL BASE OF NONCOMBUSTIBLE
 MATERIAL AS DETERMINED IN ACCORDANCE WITH SECTION
 703.4.1 WITH A SURFACING NOT MORE THAN 0.125 INCH (3.18
 MM) THICK THAT HAS A FLAME SPREAD INDEX NOT GREATER
 THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL
 723 SHALL BE ACCEPTABLE AS NONCOMBUSTIBLE MATERIALS.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-04-16 Cont ID  
Sent By rlecky Date 2015-04-16 Time 13:16 Rev Time 0.00
Received By rlecky Date 2015-04-16 Time 13:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-06-03 Cont ID  
Sent By PLEDUC Date 2015-06-03 Time   Rev Time 0.00
Received By pleduc Date 2015-06-03 Time 13:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-04-27 Cont ID  
Sent By pleduc Date 2015-04-27 Time   Rev Time 0.00
Received By pleduc Date 2015-04-27 Time 15:28 Sent To  
Notes
2015-04-27 15:44:28THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) SHEET G 101, PROVIDE NOTES INDICATING; THE PROPOSED
 PROJECT SHALL MEET THE REQUIREMENTS OF THE 5TH EDITION
 OF FLORIDA FIRE PREVENTION CODE INCLUDING THE 2012
 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER APPLICABLE
 CODES OR STANDARDS.
 FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 13, 2010 EDITION.
 FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 72, 2010 EDITION.
 CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 241, 2009 EDITION.
 ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION.
  
 2) SHEET G101, PROVIDE A HORIZONTAL FRONT VIEW DRAWING
 OF THE FIRE PLACE UNIT INDICATING DIMENSIONS OF STEEL
 WALL AND TO NEAREST COMBUSTIBLES.
  
 3) SHEET G101, PROVIDE A NOTE, THE NATURE OF THE
 REMODEL REQUIRES AN EVALUATION OF THE FIRE ALARM AND
 SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE.
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  
 4) ADDRESS BUILDING COMMENTS.
  
 5) ADDITIONALL COMMENTS MAY BE GENERATED ON REVIEW OF
 THE PROVIDED ADDITIONAL INFORMATION NOTED ABOVE.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-06-12 Cont ID  
Sent By jwitmer Date 2015-06-12 Time 09:43 Rev Time 0.00
Received By jwitmer Date 2015-06-01 Time   Sent To  
Notes
2015-06-02 13:42:32B44

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-05-16 Cont ID  
Sent By hmoser Date 2015-05-16 Time 12:06 Rev Time  
Received By hmoser Date 2015-04-03 Time   Sent To  
Notes
2015-04-04 08:54:35B19

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-06-12 Cont ID  
Sent By HMOSER Date 2015-06-12 Time 09:43 Rev Time 0.00
Received By jwitmer Date 2015-06-12 Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-05-16 Cont ID  
Sent By hmoser Date 2015-05-16 Time 12:06 Rev Time 0.00
Received By hmoser Date 2015-05-16 Time 11:21 Sent To  
Notes
2015-05-16 12:05:57PLAN DENIED
 PLEASE PROVIDE A LISTING FOR THE VENTLESS
 FIREPLACE
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-85-6676
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-06-12 Cont ID  
Sent By jwitmer Date 2015-06-12 Time 09:43 Rev Time 0.00
Received By jwitmer Date 2015-06-12 Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-05-10 Cont ID  
Sent By tklarge Date 2015-05-10 Time 06:21 Rev Time 0.00
Received By tklarge Date 2015-05-10 Time 05:40 Sent To  
Notes
***NONE***