| Plan Review Stops For Permit 15031385 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-04-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-04-27 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-04-26 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2015-04-26 11:12:40 | SENT REQUEST TO APPLICANT TO CLARIFY SOME ISSUES. | | | RETURNED SUBMITTAL TO R04. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-19 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-05-19 |
Time |
15:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-04-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-04-27 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-04-27 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2015-04-27 14:37:56 | 1ST REVIEW: FBC 2010 | | | | | | PLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION: | | | | | | FBC- 107.3.5.3 ? ELECTRIC SERVICE RISER WITH WIRE | | | SIZES, CONDUIT DETAIL AND GROUNDING DETAIL FOR EXISTING | | | SERVICE AND COMPLETE LOAD CALCULATIONS, PANEL SCHEDULES | | | AND SHOW CIRCUITS AND WIRING METHOD ON FLOOR PLAN. | | | | | | NEC 210.12B - OUTLETS TO BE AFCI PROTECTED. | | | | | | NEC 210.52 (B) (3) - KITCHEN COUNTER TOP RECEPTACLES | | | SHALL BE SUPPLIED BY NO FEWER THAN TWO SMALL APPLIANCE | | | BRANCH CIRCUITS. | | | | | | NEC 210.63 - PROVIDE A GFI SERVICE OUTLET FOR WITHIN | | | 25? OF MECHANICAL EQUIPMENT. | | | | | | NEC 406.11- PROVIDE TAMPER RESISTANT RECEPTACLES. | | | | | | NEC 250.56- SERVICE GROUNDING ELECTRODE TO BE AUGMENTED | | | BY AN ADDITIONAL ELECTRODE 6FEET AWAY OR PROVIDE | | | EVIDENCE OF RESISTANCE TO GROUND OF 25 OHMS OR LESS. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2015-05-29 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-29 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-05-29 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2015-04-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-04-27 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-04-27 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2015-04-27 14:43:19 | 1ST REVIEW: FBC 2010 | | | | | | PROVIDE GAS APPLIANCE AND SPECIFICATIONS WITH RISER | | | DIAGRAM AS A SEPARATE SUBMITTAL. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-19 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-05-19 |
Time |
08:10 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-04-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-04-22 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-04-22 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2015-04-22 15:59:27 | WINDOW INFILL REQUIRES SUBMITTAL OF COA APPLICATION. | | | QUESTIONS CONTACT FRIEDERIKE MITTNER, CITY HISTORIC | | | PRESERVATION PLANNER AT 822-1457. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-19 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-05-07 |
Time |
10:22 |
Sent To |
HIST |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-04-27 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-03-31 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2015-04-01 09:06:15 | SENT TO R4 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2015-04-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-04-27 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-04-27 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-04-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-04-27 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-04-27 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-04-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-04-22 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-04-22 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|