| 2015-04-02 09:29:31 | |
| | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15031194 |
| | ADD: 777 S. FLAGLER DR. SUITE # 136 |
| | CONT: JIM RAPP |
| | TEL: (561)248-6411 |
| | E-MAIL: [email protected] |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015 |
| | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| | ELECTRONICALLY |
| | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| | SUBMISSION OPTIONS ARE AS FOLLOWS: |
| | 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| | NAMING CONVENTION FOR EACH DOCUMENT |
| | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| | AVAILABLE |
| | |
| | 1ST REVIEW |
| | DATE: THURS. APRIL 02/2015 |
| | ACTION: DENIED |
| | |
| | 1) SHEET A2 OFFICE # 4 IS NEW AND HAS (2) INSWING |
| | DOORS, THE NEW DOORS DO NOT PROVIDE IF THEY ARE 3'-0" |
| | OR 2'-10" EACH. DEPENDING ON THE SIZE OF THE DOOR |
| | COMPLIANCE WITH MAY OR MAY NOT BE ACHIEVED, 2010 |
| | FBC-ACCESSIBILITY CODE 404.2.6 DOORS IN SERIES. |
| | |
| | 2) SHEET A2. NEW RESTROOM( NOT BATHROOM) IN THE OLD |
| | SERVER LOCATION, IS NOT DIMENSIONED. IT APPEARS THIS |
| | NEW RESTSROOM IS DESIGNED AS A ACCESSIBLE RESTROOM WITH |
| | PEDISTALL SINK AND GRAB BARS, THE MINIMUM DIMENSION |
| | WITH THE FIXTURES ON THE BACK WALL IS 7'-1" WITH THE |
| | LAV CENTERED 15 INCHES FROM WALL LAV OVERALL DIMENSION |
| | OF 19 INCHES IN WIDTH WILL GIVE COMPLIANCE OF 60 INCHES |
| | CLEARANCE IN COMPLIANCE WITH FBC-ACCESSIBILITY CODE |
| | 604.3.2. |
| | |
| | 3)SHEET A2. THE NEW RESTROOM AND PRIVATE OFFICE SHOWS |
| | NEW GRAB BARS BEING INSTALLED ON THE BACK AND SIDE |
| | WALLS. THE PLANS DO NOT PROVIDE ELEVATIONS WITH THE |
| | REQUIRED DIMENSIONS FOR THE GRAB BARS NOR DOES THE |
| | PLANS PROVIDE THE STRENGHT REQUIREMENTS FOR THE |
| | BACKING. |
| | 2010 FBC-ACCESSIBILITY CODE 604.5.1, 604.5.2 & 609.8 |
| | STRUCTURAL STRENGHT. |
| | |
| | 4) SHEET A2.THE CONFERENCE ROOM TO THE RIGHT OF THE |
| | PAGE SHOWS A KITCHEN IN THIS ROOM. NOTE WHEN A KITCHEN |
| | IS IN A COMMERCIAL APPLICATION COMPLIANCE WITH 2010 |
| | FBC-B F] 904.2.1 COMMERCIAL HOOD AND DUCT SYSTEMS. EACH |
| | REQUIRED COMMERCIAL KITCHEN EXHAUST HOOD AND DUCT |
| | SYSTEM REQUIRED BY THE FLORIDA FIRE PREVENTION CODE OR |
| | CHAPTER 5 OF THE FLORIDA BUILDING CODE, MECHANICAL TO |
| | HAVE A TYPE I HOOD SHALL BE PROTECTED WITH AN APPROVED |
| | AUTOMATIC FIRE-EXTINGUISHING SYSTEM INSTALLED IN |
| | ACCORDANCE WITH THIS CODE. |
| | |
| | 5) SHEET A2. BEHIND THE AREA OF ALTERATIONS IS A |
| | CORRIDOR WITH (2) EXISTING DOORS THAT DO NOT COMPLY |
| | WITH 2010 FBC-ACCESSIBILITY CODE 404.2.4. PLEASE EITHER |
| | SHOW COMPLIANCE WITH THE CODE SECTION PROVIDED OR |
| | PRODUCE A LETTER SHOWING THE CONTRACTOR HAS MET THE |
| | COST ASSOCIATED WITH DISPROPORTIONATE COST. NOTE THE |
| | ORDER OF EXPENDITURES ASSOCIATED IN ACCESSIBLE |
| | UPGRADES, AND WHAT ITEMS CAN BE INCLUDED. 202.4.1 |
| | DISPROPORTIONATE COST. |
| | ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF |
| | TRAVEL TO THE ALTERED AREA WILL BE DEEMED |
| | DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE |
| | COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE |
| | PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS |
| | EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF |
| | TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING |
| | AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE |
| | ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING |
| | RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, |
| | ENLARGING TOILET STALLS, INSULATING PIPES, OR |
| | INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS |
| | ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH |
| | AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, |
| | INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT |
| | TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING |
| | AN INACCESSIBLE DRINKING FOUNTAIN. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |
| | |
| | |