| Plan Review Stops For Permit 15031039 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2015-04-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-04-12 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-04-12 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2015-04-12 11:03:42 | ADDRESS HAS BEEN CHANGED FROM 650 OKEECHOBEE | | | (CONVENTION CENTER ADDRESS) TO 1099 FLORIDA AVENUE (NEW | | | ADDRESS FOR PARKING GARAGE) | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-05-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-05-18 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-05-18 |
Time |
16:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-03-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-03-25 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-03-25 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2015-03-25 10:51:56 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. GEOTECHNICAL REPORT REQUIRED FOR VIBROFLOTATION, FBC | | | 1803.1. | | | | | | 2. PROVIDE A PLAN WHICH DOCUMENTS LOCATION OF | | | VIBROFLOTATION, FBC 107. | | | | | | 3. PROVIDE INFORMATION TO DOCUMENT THE INDIVIDUAL AND | | | COMPANY RESPONSIBLE FOR MONITORING THE VIBROFLOTATION. | | | A CONTRACT IS RECOMMENDED BUT OTHER FORMS OF | | | DOCUMENTATION WOULD ALSO BE CONSIDERED, FBC 1803, FBC | | | 107. | | | | | | 4. IT IS RECOMMENDED THAT CONTRACTOR ADVISE THE | | | RESIDENTS ADJACENT TO PROPOSED CONSTRUCTION OF WORK | | | PRIOR TO COMMENCEMENT. PROPERTY OWNERS IN THE ADJACENT | | | TOWNHOUSES HAVE EXPRESSED CONCERN REGARDING THE | | | STRUCTURAL IMPACT OF CONSTRUCTION AND CONTRACTOR HAS | | | EXPLAINED HOW THIS WILL BE ADDRESSED, FBC 3307.1. PER | | | CONTRACTOR, A STRUCTURAL ANALYSIS OF THE ADJACENT | | | STRUCTURES WILL BE PERFORMED AND DOCUMENTED PRIOR TO | | | CONSTRUCTION. | | | | | | IF THE ANALYSIS DISCUSSED IS NOT DONE PRIOR TO ISSUANCE | | | OF THIS VIBROFLOTATION PERMIT, CONTRACTOR IS TO PROVIDE | | | A LETTER STATING WHY THIS IS NOT NECESSARY AT THIS | | | TIME. IT IS RECOMMENDED THAT CONTRACTOR PROVIDE | | | INFORMATION REGARDING THE TIMING AND NATURE OF THIS | | | PERMIT TO THE RESIDENTS PRIOR TO COMMENCEMENT. | | | | | | 5. ADVISORY ONLY - CONSTRUCTION HOURS ARE 7AM - 7PM | | | MONDAY THROUGH FRIDAY; 8AM - 8PM WEEKENDS, CITY OF WEST | | | PALM BEACH MUNICIPAL CODE SECTION 34-72. A WRITTEN | | | EXCEPTION MAY BE GRANTED BY THE BUILDING OFFICIAL; | | | PLEASE SUBMIT ANY SUCH REQUESTS (IF NEEDED) TIMELY TO | | | [email protected], CC [email protected] AND [email protected]. | | | | | | 6. ADVISORY ONLY - THE VALUE HAS BEEN ADJUSTED TO BE | | | CONSISTENT WITH THE CONTRACTOR SUPPLIED "COST ESTIMATE | | | OF WORK" (FROM $200,000 TO $235,330). IF THIS IS NOT | | | CORRECT, PLEASE ADVISE, PREFERABLY BEFORE THE FEES ARE | | | PAID. | | | | | | 7. ADVISORY ONLY - A UNIQUE ADDRESS WILL BE ASSIGNED TO | | | THIS STRUCTURE. CONTRACTOR WILL BE NOTIFIED OF THE NEW | | | ADDRESS WHEN ASSIGNED. | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2015-05-20 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-05-20 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-05-20 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2015-04-21 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-04-21 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-04-21 |
Time |
08:31 |
Sent To |
I |
|
| Notes |
| 2015-05-14 08:30:01 | BOND RECEIVED 5/12/2015 | | 2015-04-21 09:26:40 | 1. PLEASE SUBMIT A STORMWATER POLLUTANT PROTECTION PLAN | | | (SWPPP) FOR THE ENGINEERING DEPARTMENT?S REVIEW AND | | | APPROVAL. (CODE OF ORDINANCES. SECTION 94-450) | | | | | | 2. APPLICANTS FOR DEMOLITION AND/OR BUILDING PERMITS TO | | | PERFORM LAND DISTURBING CONSTRUCTION AND LAND | | | DEVELOPMENT ACTIVITIES SHALL SUBMIT A BOND OR DEPOSIT | | | IN AN AMOUNT COVERING THE COST ASSOCIATED WITH | | | IMPLEMENTATION OF THE SWPPP LAND STABILIZATION OF THE | | | SITE. PLEASE SUBMIT A COPY OF THE AUTOCALC CERTIFIED | | | COST ESTIMATE FORM AND A BOND FOR THE LAND | | | STABILIZATION OF THE SITE. THE AUTOCALC SPREADSHEET CAN | | | BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ THE | | | BOND WILL BE RELEASED UPON APPROVED INSPECTION OF | | | TIE-BEAMS OR SIMILAR VERTICAL CONSTRUCTION. (CITY CODE | | | SECTION 94-450) | | | | | | KELLY CRANFORD, P.E. | | | LAND DEVELOPMENT ENGINEER | | | PUBLIC WORKS DEPARTMENT | | | CITY OF WEST PALM BEACH | | | [email protected] | | | 561-494-1098 (OFFICE) | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
N |
Date |
2015-04-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-04-17 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-04-17 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2015-04-17 12:50:29 | NO FIRE REVIEW REQUIRED PER PETER LEDUC | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-06-18 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-06-18 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-06-09 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-06-09 18:12:35 | SENT TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-05-20 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-05-20 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-05-13 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2015-05-18 16:59:57 | 5/18/15 PERMIT APPLICATION PACKAGE ON SH DESK - ERIC S | | | WILL PICK UP TO REVIEW | | | | | 2015-05-15 08:39:19 | ***EXPEDITED*** | | 2015-05-14 07:49:53 | RE-SUBMITTAL SENT TO ZONING SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-21 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-04-21 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-03-25 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2015-03-25 10:57:38 | 3/25 TO ZONING | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
N |
Date |
2015-03-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-03-25 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-03-25 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2015-03-25 10:52:49 | NOT REQUIRED AT THIS TIME PER RB. | | | MONITORING OF VIBROFLOTATION BY A SPECIALTY ENGINEER | | | WILL BE DOCUMENTED. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-06-17 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-06-17 |
Time |
10:18 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2015-06-17 |
Time |
10:18 |
Sent To |
PC |
|
| Notes |
| 2015-06-17 10:19:23 | TREES IDENTIFIED AS PRESERVED SHALL BE PROTECTED AND | | | TREES IDENTIFIED AS RELOCATED SHALL BE MOVED TO THE | | | INDICATED LOCATIONS. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-05-19 |
Time |
17:59 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2015-05-19 |
Time |
17:55 |
Sent To |
ENG |
|
| Notes |
| 2015-05-19 18:23:56 | FAILED | | | | | | 1. THANK YOU FOR PROVIDING THE LANDSCAPE PLANS FOR THE | | | PROJECT. PLEASE SEE THE COMMENTS BELOW FOR CORRECTIONS | | | THAT NEED TO BE MADE TO THE PLANS: | | | | | | A. MAHOGANY (EXCELLENT CONDITION) TREE NO. 8 SHOWN AS | | | REMAINING ON THE EXISTING CONDITION/TREE RELOCATION | | | PLAN SHALL BE INCLUDED ON THE LANDSCAPE PLAN. | | | | | | B. LIVE OAK (GOOD CONDITION) TREE NO. 32 IS SHOWN AS | | | RELOCATED ON THE EXISTING CONDITION/TREE RELOCATION | | | PLAN, YET IT IS SHOWN REMAINING IN PLACE ON THE | | | LANDSCAPE PLAN. THIS TREE SEEMS TO BE IN CONFLICT WITH | | | PROPOSED 8 IN. GV #3, 8 IN. DCDA #1 AND 8 IN. PIV #1. | | | | | | C. MAHOGANY (EXCELLENT AND GOOD CONDITION) TREE NOS. | | | 14, 15, 24, 28, 38 AND 122 AND LIVE OAK (GOOD | | | CONDITION) TREE NOS. 77 AND 86 ARE SHOWN AS BEING | | | REMOVED ON THE ON THE EXISTING CONDITION/TREE | | | RELOCATION PLAN. THESE TREES SHALL BE RELOCATED AND NOT | | | DESTROYED. THE MAHOGANY TREES SHALL BE USED TO FILL IN | | | THE MISSING GAPS ALONG THE SOUTH BUFFER AND THE OAK | | | TREES SHALL BE USED IN LIEU OF PURCHASING NEW OAK | | | TREES. | | | | | | 2. PLEASE SHOW THE LIMITS OF WORK UNDER THE PHASE I | | | VIBROFLOTATION PERMIT ON THE SUBMITTED LANDSCAPE PLANS | | | SO IT IS CLEAR WHICH TREES WILL BE FENCED FOR | | | PRESERVATION AND WHICH TREES WILL BE RELOCATED TO THE | | | SOUTHERN BUFFER AREA THAT WILL NEED TO BE CONSTRUCTED | | | PRIOR TO THE COMMENCEMENT OF THE VIBROFLOTATION WORK. | | | THE LIMITS OF WORK ON THIS PLAN WILL NOT INCLUDE THE | | | RIGHT-OF-WAY THAT THE PREVIOUSLY SUBMITTED PLANS | | | SHOWED. PLEASE NOTE THAT ANY PORTIONS OF THE CONVENTION | | | CENTER PARKING LOT WHICH WILL REMAIN OPEN SHALL INCLUDE | | | THE REQUIRED LANDSCAPE ISLANDS. | | | | | | 3. THE FICUS HEDGE THAT IS LOCATED ALONG THE SOUTH AND | | | EAST PROPERTY WALLS IS IN BAD HEALTH AND SHALL BE | | | REMOVED AS PART OF THIS PHASE. IT SHALL BE REPLACED | | | WITH A NATIVE HEDGE AS PART OF THE LANDSCAPE | | | INSTALLATION COMPLETION FOR THE SITE. | | | | | | 4. PLEASE VERIFY WITH THE CONSTRUCTION SERVICES | | | DIVISION IF THE SOUTHERN BUFFER AREA MAY BE INCLUDED | | | WITH THIS PERMIT, REQUIRES A SEPARATE PERMIT, OR IF IT | | | IS HANDLED VIA THE ENGINEERING PERMIT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-04-17 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2015-04-17 |
Time |
15:15 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2015-04-17 |
Time |
15:15 |
Sent To |
ENG |
|
| Notes |
| 2015-04-17 15:43:15 | FAILED | | | | | | 1) THE SUBMITTED LANDSCAPE DEMOLITION PLAN INDICATES | | | THAT THE ENTIRE LANDSCAPE WITHIN THE HATCHED AREA WILL | | | BE DEMOLISHED, TO INCLUDE THE TREES THAT ARE TO REMAIN | | | AND THAT ARE TO BE RELOCATED. | | | | | | 2) NO INFORMATION HAS BEEN PROVIDED AS TO HOW THE TREES | | | DESIGNATED TO BE PRESERVED WILL BE PROTECTED FROM | | | CONSTRUCTION. | | | | | | 3) THE TREES DESIGNATED FOR RELOCATION ARE NOT TO BE | | | MOVED OFF-SITE FOR STORAGE. THE SOUTHERN TREE BUFFER | | | SHALL BE CONSTRUCTED TO HOLD THE RELOCATED TREES AND | | | THE TREES SHALL BE RELOCATED TO THIS LOCATION AS PART | | | OF THE PHASE 1 WORK. | | | | | | 4) TRAILER NO. 2 IS BEING SHOWN INTERFERING WITH THE | | | TREES THAT ARE TO BE PRESERVED IN PLACE ALONG THE | | | SOUTHERN BUFFER OF THE SITE. | | | | | | 5) THERE IS WORK BEING SHOWN IN THE FLORIDA AVENUE | | | RIGHT-OF-WAY. THE CONTRACTOR SHALL SECURE A | | | RIGHT-OF-WAY PERMIT PRIOR TO ZONING APPROVING THIS | | | PERMIT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|