Plan Review Details - Permit 15031026
Plan Review Stops For Permit 15031026
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-05-08 Cont ID  
Sent By jwitmer Date 2015-05-08 Time 11:50 Rev Time 0.00
Received By jwitmer Date 2015-05-08 Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-04-25 Cont ID  
Sent By jwitmer Date 2015-04-25 Time 13:30 Rev Time  
Received By jwitmer Date 2015-04-25 Time 12:00 Sent To  
Notes
2015-04-25 13:18:27BUILDING PLAN REVIEW
 W. P. B. REVISION: 15031026
 W. P. B. PERMIT: 14060196
 ADD: 777 S. FLAGLER DR. 12TH/ 14 TH FLOORS
 CONT: WOOLEMS
 TEL: (
 E-MAIL:
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. APRIL 25/ 2015
 ACTION: DENIED
  
 1) PAGE 014- A1.09 IN COMPARE MODE THERE ARE MANY
 REVISIONS MADE TO THE PLANS THE ARE NOT CLOUDED. NEW
 EXTERIOR DOORS IN THE EXECUTIVE OFFICE 420, NO DETAILS
 THROUGH PROVIDEING FRAMING, SILL ETC.
  
 2) PAGE 014- A1.09 IN COMPARE MODE, VERSION # 2 NEW
 DOORS 1405I & 1405J SHOW BUT THERE IS NO INFORMATION
 WHAT THESE ROOMS ARE TO BE USED FOR, THEY ARE GRAY
 BOXED WHICH IS ASSUMED COMMON AREAS SUCH FOR TELEPHONE,
 ELECTRICAL ROOMS AND OR EQUIPMENT ROOMS? 107.2.1
 ADDITIONAL INFORMATION IS REQUIRED.
  
 3) PAGE 014-A1.09 IN COMPARE MODE, VERSION #2 NOT
 HIGHLIGHTED BATHROOMS 1432 & 1433 IN VERSION 1 WHEREAS
 IN VERSION # 2 ROOM 1432 IS NOW A JANITORS CLOSET AND
 ROOM 1433 IS NOW A RESTROOM. DETAIL 10/ A7.11 IN
 VERSION 2 NO SUCH SHEET IN THIS REVISION. CN NOT
 DETERMINE CODE COMPLIANCE.
  
 4) PAGE 014-A1.09 IN COMPARE MODE CORRIDOR 1434 DOOR #
 1434C WAS REMOVED FROM THE EXISITNG ELEVATOR LOBBY,
 THIS WILL AFFECT THE PRESSURIZATION OF THE ELEVATOR
 HOISTWAY, MAY NEED TO BE TESTED TO SEE IF THE INCREASED
 ROOM AREA EFFECTS THE REQUIRED PRESSURIZATION OF THE
 SHAFTWAY. 909.6.1 MINIMUM PRESSURE DIFFERENCE.
  
 5) PAGE 014-A1.09 IN COMPARE MODE NATES OFFICE EXTERIOR
 DOOR CHANGED FROM DOUBLE DOORS TO SINGLE DOOR. NOT
 BUBBLED AS A REVISION, THE SAME WITH EXTERIOR DOOR
 1447, PLEASE PROVIDE BUBBLES AND REVISION MARKERS. DOOR
 1451A IS RELOCATED NOT HIGHLIGHTED AS A REVISON. DOOR
 1412A HAS BEEN RELOCATED NO BUBBLE OR REVION MARKER.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. PLEASE SEE FIRE COMMENTS ABOUT UPDATE OF
 REVISIONS NOT APPEARING AS HIGHLIHTED OR MARKED AS A
 REVISION. UPDATE PLANS AND ALSO SUBMIT A WRITTEN
 NARRATIVE OF ALL THE CHANGES.
  
 6) PAGE 023 A1.21 IN COMPARE MODE THE ROOMS AND DOORS
 ARE NOT LABELED THERE IS NO WAY TO IDENTIFY CHANGES
 BETWEEN VERSION 1 & VERSION 2 OTHER THAN TO CLOULD WHAT
 MAYBE ISSUES, AGAIN THERE IS NO BUBBLES OR REVISION
 MARKERS WHEN IN COMPARE MODE. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL. PLEASE SEE FIRE
 COMMENTS ABOUT UPDATE OF REVISIONS NOT APPEARING AS
 HIGHLIHTED OR MARKED AS A REVISION.
  
 THIS REVIEW WILL END, NO WAY OF IDENTIFYING ITEMS
 WITHOUT ROOM AND DOOR IDENTIFICATION!!!!! A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-05-04 Cont ID  
Sent By rlecky Date 2015-05-04 Time 15:45 Rev Time 0.00
Received By rlecky Date 2015-04-30 Time 15:06 Sent To  
Notes
2015-04-30 15:46:36ELECTRIC PANEL SCHEDULES DO NOT MATCH WITH THE
 ELECTRICAL RISER PLAN. PROVIDE AN AS BUILT REVISION
 PRIOR TO FINAL INSPECTION. NEC 215.5
  
 RL

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-05-19 Cont ID  
Sent By wjolin Date 2015-05-19 Time 13:50 Rev Time 0.00
Received By wjolin Date 2015-05-19 Time 13:36 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-04-22 Cont ID  
Sent By wjolin Date 2015-04-22 Time 11:09 Rev Time 0.00
Received By wjolin Date 2015-04-21 Time 15:51 Sent To  
Notes
2015-04-22 11:09:46777 SOUTH FLAGLER DRIVE
 TRACKING #15031026
 PERMIT #14060196
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 GENERAL: AN UPDATED LIFE SAFETY PLAN IS NEEDED FOR THE
 14TH FLOOR TO ACCOMMODATE ALL THE FLOOR PLAN CHANGES.
 REVISIONS ARE NEEDED FOR THE SPRINKLER, FIRE ALARM,
 EMERGENCY LIGHTING, EXIT SIGN LOCATIONS, ETC.
  
 SHEET A1.09: THIS PLAN SHOWS A COMPLETELY REDESIGNED
 FLOOR PLAN WITH SEVERAL WALLS, DOOR LOCATIONS, ETC. NOT
 EVEN BEING CLOUDED WITH A REVISION.
  
 SHEET A1.21: NO CHANGES CLOUDED.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-05-30 Cont ID  
Sent By tklarge Date 2015-05-30 Time 10:34 Rev Time 0.00
Received By tklarge Date 2015-05-29 Time 15:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-05-29 Cont ID  
Sent By tklarge Date 2015-05-29 Time 10:10 Rev Time 0.00
Received By tklarge Date 2015-05-01 Time 11:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-05-02 Cont ID  
Sent By jwitmer Date 2015-05-02 Time 10:48 Rev Time 0.00
Received By jwitmer Date 2015-03-27 Time 10:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2015-05-02 Cont ID  
Sent By hmoser Date 2015-05-02 Time 08:03 Rev Time 0.00
Received By hmoser Date 2015-05-02 Time 07:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2015-05-30 Cont ID  
Sent By tklarge Date 2015-05-30 Time 10:34 Rev Time 0.00
Received By tklarge Date 2015-05-30 Time 09:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-05-29 Cont ID  
Sent By tklarge Date 2015-05-29 Time 10:09 Rev Time 0.00
Received By tklarge Date 2015-05-29 Time 10:07 Sent To  
Notes
2015-05-29 10:09:211_ PLUMBING COMMENTS HAVE NOT BEEN ADDRESSED. COMPLY
 WITH ALL PREVIOUS PLAN REVIEW COMMENTS FROM 4/23/15.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-04-23 Cont ID  
Sent By tklarge Date 2015-04-23 Time 11:02 Rev Time 0.00
Received By tklarge Date 2015-04-22 Time 11:53 Sent To  
Notes
2015-04-22 12:57:191) SHT. P2.2 - SHOWS A DRAIN LINE INSTALLED ABOVE THE
 CEILING. INDICATE THE TYPE OF PIPING TO BE USED.
 INDICATE ON THE PLAN IF THE AREA ABOVE THE CELING IS A
 PLENUM. IF IT IS, MATERIALS SHALL COMPLY WITH 2010 FMC
 SEC.602.2.1.
 2) SUBMITMANUFACTURER'S SPECIFICATIONS FOR THE GREASE
 TRAP. SUBMIT SIZING CALCULATIONS PER 2010 FPC
 SEC.1003.2, 1003.3.4, 1003.4.1.
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE LITTLE
 GIANT DRAINASAUR PUMP. WPB AMND. TO 2010 FPC SEC.
 107.2.1.
 4) THE EJECTOR SHALL CONNECT TO THE THE DRAINAGE SYSTEM
 IN ACCORDANCE WITH 2010 FPC SEC.712.3.5.
 5) SHT. P2.2 - SHOWS A KEYNOTE SYMBOL #6 AT A FLOOR
 SINK NEXT TO THE GREASE TRAP YET THERE IS NO KEYNOTE #6
 IN THE PLANS. CLARIFY.
 6) THE WATER SUPPLY TO THE COFFEE MACHINE SHALL BE
 PROTECTED AGAINST BACKFLOW PER 2010 FPC SEC.608.16.10.
 7) SUBMIT MANUFACTURER'S SPECIFICATIONS ON THE WATER
 SOFTENER AND WATER FILTRATION SYSTEM. SUBMIT PIPING
 DETAILS.WPB AMEND. TO 2010 FBC SEC. 107.2.1.
 8) THE SINKS IN ROOMS # 1445 & # 1422 SHALL COMPLY WITH
 THE 2010 FAC SECS. 212 & 606. THE MAXIMUM HEIGHT OF THE
 COUNTER SHALL BE 34 INCHES AND A CLEAR FLOOR SPACE
 SHALL BE PROVIDED PER THE FAC SEC.606.2.
 9) IDENTIFY THE ROOM WITH THE SINK THAT IS ADJACENT TO
 ROOM # 1418. THE SINK IN THIS ROOM MAY HAVE TO COMPLY
 WITH THE FAC SECS.212 & 606.
 10) SHT. P5.1 - THE FOLLOWING PLUMBING VIOLATIONS
 EXIST:
 1) THE LAVATORIES IN THE MEN'S AND WOMEN'S RESTROOM DO
 NOT APPEAR TO BE VENTED AND APPEAR TO BE DRAWN AS "S"
 TRAPS. 2010 FPC SEC.901.1.1, 1002.3. CLARIFY.
 2) URINALS APPEAR TO BE "S" TRAPPED AS DRAWN. CLARIFY.
 3) THE DESIGN OF THE PLUMBING SYSTEM FOR THE MEN'S AND
 WOMEN'S RESTROOM DOES NOT COMPLY WITH THE PLUMBING CODE
 FOR A WET VENT SYSTEM OR A CIRCUIT SYSTEM (FPC 909 &
 911).
 4) SK-3 IN EXECUTIVE PREP AREA IS S-TRAPPED ON THE
 RISER. 2010 FPC SEC.901.1.1, 1002.3. CLARIFY.
 5) SIZE ALL SECTIONS OF THE VENTING SYSTEM FOR THE NEW
 PLUMBING FIXTURES ( LAVS, JANITOR SINK, ETC.)
 6) THE WASHING MACHINE SALL DISCHARGE INTO A 3" STACK
 PER THE 2010 FPC SEC.406.3.
 7) THE FLOOR DRAIN COLLECTING THE PAN DRAINS IS NOT
 CONNECTED TO ANYTHING ON THE RISER. CLARIFY.
 11) IF THERE ARE GAS APPLIANCES IN THE EXECUTIVE PREP
 AREA, SUBMIT MANUF. SPECIFICATION SHEETS FOR ALL GAS
 EQUIPMENT AND SUBMIT A GAS RISER FOR REVIEW. WPB AMEND.
 TO 2010 FBC SEC. 107.2.1.
  
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2015-07-08 Cont ID  
Sent By skennedy Date 2015-07-08 Time 14:13 Rev Time 0.00
Received By skennedy Date 2015-07-08 Time 12:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2015-06-08 Cont ID  
Sent By rbrown Date 2015-06-08 Time 22:11 Rev Time 0.00
Received By rbrown Date 2015-06-08 Time 22:11 Sent To  
Notes
2015-06-08 22:16:34ELECTRONIC SIGNATURE REVIEW
 *******DENIED*******
 ROBERT BROWN (561) 805 6652
 E-MAIL: [email protected]
  
 THE ARCHITECTURAL PLAN SHEETS DO NOT SHOW THE NAME AND
 LICENSE NUMBER OF THE ARCHITECT OF RECORD, THADDEUS
 SIEMASKO, AR93805. THIS IS A REQUIREMENT OF THE
 FOLLOWING SECTION FROM FLORIDA BUILDING CODE, CITY OF
 WEST PALM BEACH AMENDMENTS TO CHAPTER 1,
 ADMINISTRATIVE.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 ELECTRONIC MEDIA DOCUMENTS SHALL BE
 SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN
 DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS
 CODE AND RELEVANT LAWS, ORDINANCES, RULES
 AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE
 QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL
 CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR
 ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN. (SEE ALSO SECTION 107.3.5).
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS