| 2015-04-01 12:43:24 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15030965 |
| | ADD: 8264 NORTHLAKE BLVD. |
| | CONT: J. RAWN ENTERPRISES |
| | TEL: (561)478-7445 |
| | E-MAIL: [email protected] |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015 |
| | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| | ELECTRONICALLY |
| | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| | SUBMISSION OPTIONS ARE AS FOLLOWS: |
| | 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| | NAMING CONVENTION FOR EACH DOCUMENT |
| | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| | AVAILABLE |
| | |
| | 1ST REVIEW |
| | DATE: WED. APRIL 01/2015 |
| | ACTION: DENIED |
| | |
| | 1) PLEASE PROVIDE A FLOOD ELEVATION CERTIFICATE FOR THE |
| | PROPOSED WORK, PLEASE PROVIDE THE ELEVATIONS IN NGVD. |
| | FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF ORDINANCES |
| | SECTION 94-546. STRUCTURE IS LOCATED IN AN "AH" FLOOD |
| | ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED. |
| | PLEASE REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS |
| | REQUIRE AN ADDITIONAL 6 INCHES OF ELEVATION. |
| | |
| | FEMA FORM OMB NO. 1660-0008 EXPIRES: |
| | JULY 31/2015 |
| | FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR |
| | USE, EFFECTIVE AUGUST 1/ 2013, THROUGH JULY 31/ 2015. |
| | FORM. ADDITIONAL INFORMATION ON THE DIFFERENCES, THE |
| | NEW FORM, AND INSTRUCTIONS ARE AVAILABLE AT: |
| | HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM |
| | |
| | 2) SHEET A2.0 INDICATES THE INSTALATION OF NEW ANDERSON |
| | 400 SERIES PERMA-SHIELD VINYL CLAD WOOD CASEMENT |
| | WINDOWS, LMI |
| | NOA07-0820.02. NOTE THIS PRODUCT APPROVAL HAS EXPIRED |
| | ON 09/19/2012. |
| | THE FLORIDA PRODUCT APPROVAL SYSTEM DOES HAVE TESTING |
| | FOR PERMA-SHIELD VINYL CLAD WOOD CASEMENT WINDOWS, LMI |
| | TESTING NUMBER IS FL12496-R2 THIS IS A CASEMENT WINDOW |
| | WITH +/- 70 PSF. I'VE PRINTED THEM OUT TO BE PART OF |
| | THE PERMIT PACKAGE. |
| | THEY STILL WILL NEED TO BE REVIEWED BY THE DESSIGNER OF |
| | RECORD AND SHOP DRAWING STAMP OF APPROVAL APPLIED. |
| | |
| | 3A) SHEET A2.0 ALSO INDICATES THE REUSE OF THE EXISTING |
| | DOORS WHICH WERE INSTALLED BEFORE THE LARGE MISSILE |
| | IMPACT TESTING REQUIREMENTS. A SITE SPECIFIC APPROVAL |
| | WILL NEED TO BE ACCOMPLISHED BY AN ENGINEER PROVIDING |
| | CALCULATIONS AND OR RATIONAL ANALYSIS FOR THE EXISTING |
| | DOOR AND FRAME FOR THE WIND PRESSURES AND THE ANCHORING |
| | OF THE FRAME TO THE MAIN WIND FORCE RESISTING SYSTEM. |
| | THE OTHER ISSUE IS THE DOORS WILL REQUIRE STORM |
| | SHUTTERS, EITHER PROVIDE NEW STORM SHUTTERS FOR THIS |
| | OPENING OR THE ENGINEER WILL ALSO BE REQUIRED TO DO |
| | SITE SPECIFIC APPROVAL OF THE EXISTING STORM SHUTTER |
| | SYSTEM PROVIDING CALCULATIONS AND OR RATIONAL ANALYSIS |
| | OF THE STORM SHUTTERS, AND ANCHORING OF SHUTTERS TO THE |
| | STRUCTURE. |
| | |
| | 1703.4 PERFORMANCE. |
| | SPECIFIC INFORMATION CONSISTING OF TEST REPORTS |
| | CONDUCTED BY AN APPROVED TESTING AGENCY IN ACCORDANCE |
| | WITH STANDARDS REFERENCED IN CHAPTER 35, OR OTHER SUCH |
| | INFORMATION AS NECESSARY, SHALL BE PROVIDED FOR THE |
| | BUILDING OFFICIAL TO DETERMINE THAT THE MATERIAL MEETS |
| | THE APPLICABLE CODE REQUIREMENTS. |
| | |
| | 1703.4.1 RESEARCH AND INVESTIGATION. |
| | SUFFICIENT TECHNICAL DATA SHALL BE SUBMITTED TO THE |
| | BUILDING OFFICIAL TO SUBSTANTIATE THE PROPOSED USE OF |
| | ANY MATERIAL OR ASSEMBLY. IF IT IS DETERMINED THAT THE |
| | EVIDENCE SUBMITTED IS SATISFACTORY PROOF OF PERFORMANCE |
| | FOR THE USE INTENDED, THE BUILDING OFFICIAL SHALL |
| | APPROVE THE USE OF THE MATERIAL OR ASSEMBLY SUBJECT TO |
| | THE REQUIREMENTS OF THIS CODE. THE COSTS, REPORTS AND |
| | INVESTIGATIONS REQUIRED UNDER THESE PROVISIONS SHALL BE |
| | PAID BY THE APPLICANT. |
| | |
| | 1703.4.2 RESEARCH REPORTS. |
| | SUPPORTING DATA, WHERE NECESSARY TO ASSIST IN THE |
| | APPROVAL OF MATERIALS OR ASSEMBLIES NOT SPECIFICALLY |
| | PROVIDED FOR IN THIS CODE, SHALL CONSIST OF VALID |
| | RESEARCH REPORTS FROM APPROVED SOURCES. |
| | |
| | 3B) DEPENDING IF NEW DOORS WITH LARGE MISSILE RATED |
| | DOORS ARE USED OR IF STORM SHUTTERS, A LETTER FROM THE |
| | CITY PROJECT ENGINEER |
| | OF THE GRASSY WATERS NATURE CENTER THAT THE |
| | ADMINISTRATOR OF THE GRASSY WATER NATURE CENTER |
| | ROUTINELY PRACICES THE PLACEMENT AND REMOVAL OF THE |
| | STORM SHUTTERS IN ORDER TO PROPERLY SECURE THE SITE IN |
| | EMERGENCY CONDITIONS. |
| | |
| | IN ADDITION, THE ADMINISTRATOR OF THE FACILITY |
| | ROUTINELY HAVE USED AND WILL CONTINUE TO USE PROPER |
| | CAUTION TO COMPLETELY EVACUATE THE FACILITY PRIOR TO |
| | SECURING THE HURRICANE SHUTTERS OVER THE EXISTING AND |
| | RELOCATED DOOR ASSEMBLY. |
| | |
| | 4) THE STRUCTURAL SHEET S-1.0 WILL NEED TO BE UPDATED |
| | TO THE 2010 FBC-B AND ANSI/ASCE &-10 FOR THE WIND |
| | DESIGN AND THE ASSOCIATED PRESSURES. |
| | WIND DESIGN CRITERIA |
| | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- |
| | CHAPTER 6 OF ASCE 7-10. |
| | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C |
| | 1609.3 WIND SPEED CONVERSION |
| | 4.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 |
| | |
| | 4.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. |
| | |
| | 4.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.4 & ASCE 7-10 |
| | |
| | 4.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. |
| | |
| | 4.5) COMPONENTS & CLADDING PRESSURES POSITIVE & |
| | NEGATIVE TABLE 1609.2(2) . |
| | |
| | 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 6) THE SUBMITTED ROOFING APPROVAL POLYGLASS |
| | SELF-ADHERRED ROOF SYSTEMS OVER WOOD DECK NOA |
| | 13-1217.01. THE SUB-SYSTEM TO BE APPLIED HAS NOT BEEN |
| | IDENTIFIED NOR THE MAXIMUM DESIGN PRESSURES OR |
| | LIMITATIONS. |
| | |
| | 7) IF NEW STORM SHUTTER ARE TO BE SUBMITTED, PLEASE |
| | COMPLY WITH: PROVIDE STORM PANEL INFORMATION WITH |
| | INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC |
| | ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT |
| | GLAZING. FBC 1609.1.2. |
| | |
| | FL BLD CODE 2010 SECTION 107.2.5., |
| | 1609.1.2, 1715.8 & EXIST BUILD CODE 606.4 PROCEDURES: A |
| | COMPLETE INSTALLATION SCHEDULE SUMMARIZING & |
| | IDENTIFYING OPENING SIZES, STORY HEIGHTS, UNIT MARK |
| | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM BAR REINFORCING |
| | REQUIREMENTS, WALL PRESSURE ZONES, SLAT TYPES, ETC., |
| | SHALL BE SUBMITTED AT TIME OF PERMIT APPLICATION TO |
| | FACILITATE PLAN REVIEW AND PERMIT ISSUANCE |
| | |
| | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |