Plan Review Details - Permit 15030964
| Plan Review Stops For Permit 15030964 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-07-14 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-07-14 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2015-07-14 12:14:26 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | COMMENTS FROM PREVIOUS LIST, NOT ADDRESSED: | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS. | | | | | | 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | | HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND | | | OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE | | | CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION | | | NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | | HEIGHT: | | | | | | STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS | | | - AWNING, CASEMENT, SINGLE HUNG? | | | | | | STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE. | | | CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE | | | WINDOW IS FULLY OPEN. | | | | | | STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE. | | | THIS CAN BE OBTAINED FROM THE MANUFACTURER. | | | | | | 3. SMALL MISSILE IMPOACT PRODUCT APPROVAL WAS | | | SUBMITTED. LARGE MISSILE IMPACT REQUIRED. RESUBMITTAL | | | FORM STATES "ALL WINDOWS SINGLE HUNG IMPACT." BELOW 30' | | | LARGE MISSILE IMPACT PROTECTION IS REQUIRED. | | | FBC1609.1.4, FBC R 301.2.1.2. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-04-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-04-08 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-04-08 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2015-04-08 13:57:50 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS. | | | | | | 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | | HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND | | | OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE | | | CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION | | | NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | | HEIGHT: | | | | | | STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS | | | - AWNING, CASEMENT, SINGLE HUNG? | | | | | | STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE. | | | CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE | | | WINDOW IS FULLY OPEN. | | | | | | STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE. | | | THIS CAN BE OBTAINED FROM THE MANUFACTURER. | | | | | | 3. SMALL MISSILE IMPOACT PRODUCT APPROVAL WAS | | | SUBMITTED. IMPACT PROTECTION REQUIRED, FBC1609.1.4, FBC | | | R 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | | ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE | | | (AVAILABLE IN THE LOBBY AND AT: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | | | IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 606.4, | | | PROVIDE CALCULATIONS. | | | | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-07-07 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-07-07 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-07-07 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2015-07-07 08:28:24 | ALL SINGLE HUNGS TO MATCH ORIGINAL PATTERN. WHITE | | | FRAMES CLEAR/LOW-E GLASS. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-03-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-03-30 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-03-30 |
Time |
14:52 |
Sent To |
B |
|
| Notes |
| 2015-03-30 14:53:10 | NEED PHOTOS, FLOORPLAN AND ELEVATIONS TO UNDERSTAND | | | GRID PATTERN OF FIXED WINDOW. FM SPOKE TO BROCK | | | CONTARACTOR 3/30, HE WILL SUBMIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-07-14 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-07-07 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-04-08 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-04-08 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
|