| 2015-03-24 10:35:52 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15030904 |
| | ADD: 400 HIBISCUS ST. |
| | CONT: LATITE ROOFING |
| | TEL: (954)772-3446 |
| | E-MAIL: [email protected] |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015 |
| | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| | ELECTRONICALLY |
| | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| | SUBMISSION OPTIONS ARE AS FOLLOWS: |
| | 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| | NAMING CONVENTION FOR EACH DOCUMENT |
| | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| | AVAILABLE |
| | |
| | 1ST REVIEW |
| | DATE: TUES. MARCH 24/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) THE PERMIT APPLICATION UNDER THE DESCRIPTION OF WORK |
| | READS, ROOF REPAIRS TO FLAT ROOF AND STANDING SEAM |
| | METAL ROOF. PLEASE REVIEW THE 2010 FBC-EXISTING |
| | BUILDING CODE SECTION 611.1.1 NOT MORE THAN 25 PERCENT |
| | OF THE TOTAL ROOF AREA OR ROOF SECTION OF ANY EXISTING |
| | BUILDING OR STRUCTURE SHALL BE REPAIRED, REPLACED OR |
| | RECOVERED IN ANY 12 MONTH PERIOD UNLESS THE ENTIRE |
| | ROOFING SYSTEM OR ROOF SECTION CONFORMS TO REQUIREMENTS |
| | OF THIS CODE. |
| | |
| | WHEN YOU READ ROOF REPAIRS NOT MORE THAN 25% THE |
| | ROOFING SYSTEM APPEARS TO BE ALMOST THE WHOLE ROOF WHEN |
| | YOU INCLUDE THE METAL ROOF AND THE AREA OF THE FLAT |
| | ROOFS ARE UNKNOWN. THERE IS GREY AREAS IN THE CODE |
| | BETWEEN WHAT IS CONSIDERED A REPAIR AND WHAT IS |
| | CONSIDERED MAITENANCE, IS THE WORK ON THE METAL ROOF |
| | AREAS TO BE CONSIDERED MAINTENANCE, PLEASE PROVIDE THE |
| | PERCENTAGE OF ROOFING THE METAL ROOF COVERS AND THE |
| | PERCENTAGE OF THE FLAT ROOF AND WHAT PERCENT OF THE |
| | FLAT ROOF IS BEING REPAIRED. |
| | |
| | 2) WITH THE FLAT ROOF AREA, WE WILL NEED A PRODUCT |
| | APPROVAL AND KNOWN SUB-SYSTEM FOR OUR INSPECTORS TO |
| | INSPECT THE FLAT ROOF REPAIR. NOTE THEY MAY REQUIRE |
| | ENHANCED FASTENING IN ROOF ZONES 2 & 3, IT APPEARS THE |
| | PARAPET IS LESS THAN 3'-0" THE OTHER ISSUE IS THE |
| | HEIGHT OF THE BUILDING IS 16 FT. THIS IS A 2 STORY |
| | BUILDING THE CLEAR CEILING HEIGHT WITH NO FRAMING |
| | MEMBERS FOR THE 2 STORIES WOULD BE A MINIMUM OF 16 |
| | FEET. C EXPOSURE W/ HEIGTH MULTIPLIER WILL BE REQUIRED. |
| | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- |
| | CHAPTER 6 OF ASCE 7-10. |
| | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C |
| | AN EXPOSURE CATEGORY SHALL BE DETERMINED IN ACCORDANCE |
| | WITH 1609.4 & ASCE 7-10 |
| | A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * SHALL |
| | BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. |
| | |
| | MEAN ROOF HEIGHT. THE AVERAGE OF THE ROOF EAVE HEIGHT |
| | AND THE HEIGHT TO THE HIGHEST POINT ON THE ROOF |
| | SURFACE, EXCEPT THAT EAVE HEIGHT SHALL BE USED FOR ROOF |
| | ANGLE OF LESS THAN OR EQUAL TO 10 DEGREES (0.18 RAD). |
| | |
| | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 |
| | COMPONENTS & CLADDING, FLORIDA DEPARTMENT OF COMMUNITY |
| | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF |
| | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE |
| | PRODUCT APPROVALS: |
| | (31)() ROOFING PRODUCTS AND ASSEMBLIES |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |