| Plan Review Stops For Permit 15030841 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-24 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-24 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2015-06-24 13:07:42 | WINDOWS AND DOOR REPLACED UNDER PERMIT #15031221. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-19 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-19 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2015-05-19 09:31:53 | WINDOW REPLACEMENT IS UNDER SEPARATE PERMIT #15031221. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-04-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-09 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-09 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2015-04-09 07:44:46 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) PROVIDE A FLOOR PLAN OF THE EXISTING WORK AREA, IN | | | ADDITION TO THE PROPOSED WORK. FBC 107.2.1 | | | | | | 2) PROVIDE A DETAILED SCOPE OF WORK ON THE PLANS. FBC | | | 107.2.1 | | | | | | 3) INDICATE THE NEW INTERIOR WALLS ON THE PLANS AND | | | PROVIDE AN INTERIOR WALL DETAIL. FBC 107.2.1 | | | | | | 4) R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. | | | BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM | | | SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND | | | RESCUE OPENING. THE BEDROOM WINDOW CAN NOT BE | | | ELIMINATED. | | | | | | 5) FBC-R314.3.1 ALTERATIONS, REPAIRS AND ADDITIONS. | | | WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | | | | 6) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-24 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-24 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2015-06-24 13:08:23 | RED LINED PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-19 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-19 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2015-05-19 14:42:26 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PLANS APPEAR TO SHOW THE ELECTRICAL PANEL | | | LOCATED IN THE WALL BEHIND THE CLOTHES DRYER, WHICH IS | | | NOT CODE COMPLIANT. NEC 110.26 SUFFICIENT ACCESS AND | | | WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT | | | ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE | | | OPERATION AND MAINTENANCE OF SUCH EQUIPMENT. | | | | | | 2) SHOW COMPLIANCE WITH NEC 230.70 FOR SERVICE | | | DISCONNECTING MEANS. | | | | | | 3) THE ELECTRICAL RISER ON THE PLAN SHOWS A 200 AMP | | | DISCONNECT THAT DOES NOT MATCH THE SEVICE THAT IS SHOWN | | | ON THE EAST ELEVATION. FBC 107.2.1 | | | | | | 4) FBC- 107.3.5.3 - PROVIDE AN ELECTRIC SERVICE RISER | | | DIAGRAM WITH WIRE SIZES, CONDUIT DETAIL AND GROUNDING | | | DETAIL. | | | | | | 5) THE SMOKE ALARM OUTSIDE THE MASTER BEDROOM CAN NOT | | | BE LOCATED IN THE LAUNDRY ROOM/CLOSET. FBC-R314.3 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-04-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-09 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-09 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2015-04-09 08:14:44 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) NEC 210.12 (B) - OUTLETS ARE REQUIRED TO BE AFCI | | | PROTECTED. | | | | | | 2) NEC 406.11 - TAMPER-RESISTANT RECEPTACLES ARE | | | REQUIRED. | | | | | | 3) NEC 210.11 (C) (3) AT LEAST ONE 20 - AMP BRANCH | | | CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE | | | OUTLETS. | | | | | | 4) R314.3.1 ALTERATIONS, REPAIRS AND ADDITIONS. | | | WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-05-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-05-13 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-05-13 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-04-06 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-04-06 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-03-31 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2015-04-06 16:43:40 | NEED TO MAINTAIN BALANCE OF FENESTRATION ON THIS | | | ELEVATION. QUESTIONS CONTACT FRIEDERIKE MITTNER, CITY | | | HISTORIC PRESERVATION PLANNER AT 822-1457. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-24 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-21 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2015-05-22 07:34:26 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-19 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-05-13 08:41:17 | 5/13 TO RM DESK | | | | | 2015-05-04 16:53:37 | SENT TO ZONING BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-09 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-20 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2015-03-23 10:24:39 | SENT TO R1 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-24 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-24 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2015-06-24 13:08:53 | RED LINED PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2015-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-19 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-19 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2015-05-19 13:09:42 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY PLUMBING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE CLOTHES WASHER STANDPIPE AND DRAINAGE PIPE IS | | | REQUIRED TO BE A MINIMUM OF 2 INCHES. FBC-R P3201.7 | | | | | | 2) THE CLOTHES WASHER AND LAVATORY ARE REQUIRED TO BE | | | VENTED. FBC-R P3201.5 (3) | | | | | | 3) THE VENT FOR THE WATER CLOSET IS REQUIRED TO BE 2" | | | WHICH IS 1/2 THE SIZE OF THE 4" BRANCH DRAIN PIPE. | | | FBC-R P3113.1 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-04-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-09 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-09 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2015-04-09 08:00:47 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY PLUMBING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SPECIFY THE SCOPE OF PROPOSED PLUMBING WORK ON THE | | | PLANS. FBC 107.2.1 | | | | | | 2) IF AN PLUMBING FIXTURES ARE RELOCATED OR ADDED, THEN | | | TWO COPIES OF A PLUMBING RISER DIAGRAM IS REQUIRED. FBC | | | 107.3.5.3 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-05-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-05-13 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-05-13 |
Time |
08:22 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-04-06 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2015-03-31 |
Time |
|
Sent To |
|
|
| Notes |
|
|