Plan Review Details - Permit 15030841
Plan Review Stops For Permit 15030841
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-06-24 Cont ID  
Sent By rmcdouga Date 2015-06-24 Time 13:06 Rev Time 0.00
Received By rmcdouga Date 2015-06-24 Time 13:06 Sent To  
Notes
2015-06-24 13:07:42WINDOWS AND DOOR REPLACED UNDER PERMIT #15031221.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-05-19 Cont ID  
Sent By rmcdouga Date 2015-05-19 Time 09:15 Rev Time 0.00
Received By rmcdouga Date 2015-05-19 Time 08:00 Sent To  
Notes
2015-05-19 09:31:53WINDOW REPLACEMENT IS UNDER SEPARATE PERMIT #15031221.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-04-09 Cont ID  
Sent By rmcdouga Date 2015-04-09 Time 06:56 Rev Time 0.00
Received By rmcdouga Date 2015-04-09 Time 06:56 Sent To  
Notes
2015-04-09 07:44:46PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PROVIDE A FLOOR PLAN OF THE EXISTING WORK AREA, IN
 ADDITION TO THE PROPOSED WORK. FBC 107.2.1
  
 2) PROVIDE A DETAILED SCOPE OF WORK ON THE PLANS. FBC
 107.2.1
  
 3) INDICATE THE NEW INTERIOR WALLS ON THE PLANS AND
 PROVIDE AN INTERIOR WALL DETAIL. FBC 107.2.1
  
 4) R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED.
 BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM
 SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND
 RESCUE OPENING. THE BEDROOM WINDOW CAN NOT BE
 ELIMINATED.
  
 5) FBC-R314.3.1 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS.
  
 6) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE
 CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER
 INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN
 ADDRESSED.
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-06-24 Cont ID  
Sent By rmcdouga Date 2015-06-24 Time 13:07 Rev Time 0.00
Received By rmcdouga Date 2015-06-24 Time 13:07 Sent To  
Notes
2015-06-24 13:08:23RED LINED PLANS.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-05-19 Cont ID  
Sent By rmcdouga Date 2015-05-19 Time 14:38 Rev Time 0.00
Received By rmcdouga Date 2015-05-19 Time 08:01 Sent To  
Notes
2015-05-19 14:42:26PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PLANS APPEAR TO SHOW THE ELECTRICAL PANEL
 LOCATED IN THE WALL BEHIND THE CLOTHES DRYER, WHICH IS
 NOT CODE COMPLIANT. NEC 110.26 SUFFICIENT ACCESS AND
 WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT
 ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE
 OPERATION AND MAINTENANCE OF SUCH EQUIPMENT.
  
 2) SHOW COMPLIANCE WITH NEC 230.70 FOR SERVICE
 DISCONNECTING MEANS.
  
 3) THE ELECTRICAL RISER ON THE PLAN SHOWS A 200 AMP
 DISCONNECT THAT DOES NOT MATCH THE SEVICE THAT IS SHOWN
 ON THE EAST ELEVATION. FBC 107.2.1
  
 4) FBC- 107.3.5.3 - PROVIDE AN ELECTRIC SERVICE RISER
 DIAGRAM WITH WIRE SIZES, CONDUIT DETAIL AND GROUNDING
 DETAIL.
  
 5) THE SMOKE ALARM OUTSIDE THE MASTER BEDROOM CAN NOT
 BE LOCATED IN THE LAUNDRY ROOM/CLOSET. FBC-R314.3
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-04-09 Cont ID  
Sent By rmcdouga Date 2015-04-09 Time 08:14 Rev Time 0.00
Received By rmcdouga Date 2015-04-09 Time 08:14 Sent To  
Notes
2015-04-09 08:14:44PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) NEC 210.12 (B) - OUTLETS ARE REQUIRED TO BE AFCI
 PROTECTED.
  
 2) NEC 406.11 - TAMPER-RESISTANT RECEPTACLES ARE
 REQUIRED.
  
 3) NEC 210.11 (C) (3) AT LEAST ONE 20 - AMP BRANCH
 CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE
 OUTLETS.
  
 4) R314.3.1 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS.

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2015-05-13 Cont ID  
Sent By fmittner Date 2015-05-13 Time 08:22 Rev Time 0.00
Received By fmittner Date 2015-05-13 Time 08:22 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2015-04-06 Cont ID  
Sent By fmittner Date 2015-04-06 Time 16:42 Rev Time 0.00
Received By fmittner Date 2015-03-31 Time 15:23 Sent To  
Notes
2015-04-06 16:43:40NEED TO MAINTAIN BALANCE OF FENESTRATION ON THIS
 ELEVATION. QUESTIONS CONTACT FRIEDERIKE MITTNER, CITY
 HISTORIC PRESERVATION PLANNER AT 822-1457.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-06-24 Cont ID  
Sent By rmcdouga Date 2015-06-24 Time 13:08 Rev Time 0.00
Received By rmcdouga Date 2015-05-21 Time 07:33 Sent To  
Notes
2015-05-22 07:34:26SENT TO R MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-05-19 Cont ID  
Sent By rmcdouga Date 2015-05-19 Time 14:38 Rev Time 0.00
Received By rmcdouga Date 2015-05-04 Time   Sent To  
Notes
2015-05-13 08:41:175/13 TO RM DESK
  
2015-05-04 16:53:37SENT TO ZONING BOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-04-09 Cont ID  
Sent By rmcdouga Date 2015-04-09 Time 08:15 Rev Time 0.00
Received By rmcdouga Date 2015-03-20 Time 10:24 Sent To  
Notes
2015-03-23 10:24:39SENT TO R1 SHELF FOR REVIEW. JG.

Review Stop P PLUMBING
Rev No 3 Status P Date 2015-06-24 Cont ID  
Sent By rmcdouga Date 2015-06-24 Time 13:08 Rev Time 0.00
Received By rmcdouga Date 2015-06-24 Time 13:08 Sent To  
Notes
2015-06-24 13:08:53RED LINED PLANS

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-05-19 Cont ID  
Sent By rmcdouga Date 2015-05-19 Time 13:09 Rev Time 0.00
Received By rmcdouga Date 2015-05-19 Time 08:00 Sent To  
Notes
2015-05-19 13:09:42PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY PLUMBING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE CLOTHES WASHER STANDPIPE AND DRAINAGE PIPE IS
 REQUIRED TO BE A MINIMUM OF 2 INCHES. FBC-R P3201.7
  
 2) THE CLOTHES WASHER AND LAVATORY ARE REQUIRED TO BE
 VENTED. FBC-R P3201.5 (3)
  
 3) THE VENT FOR THE WATER CLOSET IS REQUIRED TO BE 2"
 WHICH IS 1/2 THE SIZE OF THE 4" BRANCH DRAIN PIPE.
 FBC-R P3113.1
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-04-09 Cont ID  
Sent By rmcdouga Date 2015-04-09 Time 07:52 Rev Time 0.00
Received By rmcdouga Date 2015-04-09 Time 07:52 Sent To  
Notes
2015-04-09 08:00:47PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY PLUMBING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SPECIFY THE SCOPE OF PROPOSED PLUMBING WORK ON THE
 PLANS. FBC 107.2.1
  
 2) IF AN PLUMBING FIXTURES ARE RELOCATED OR ADDED, THEN
 TWO COPIES OF A PLUMBING RISER DIAGRAM IS REQUIRED. FBC
 107.3.5.3
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2015-05-13 Cont ID  
Sent By fmittner Date 2015-05-13 Time 08:22 Rev Time 0.00
Received By fmittner Date 2015-05-13 Time 08:22 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By fmittner Date 2015-04-06 Time   Rev Time  
Received By   Date 2015-03-31 Time   Sent To  
Notes
***NONE***