Plan Review Details - Permit 15030460
Plan Review Stops For Permit 15030460
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-07-09 Cont ID  
Sent By rmcdouga Date 2015-07-09 Time 17:35 Rev Time 0.00
Received By rmcdouga Date 2015-07-09 Time 17:35 Sent To  
Notes
2015-07-09 17:47:07SEE PERMIT #15030458 FOR PLANS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-04-30 Cont ID  
Sent By rmcdouga Date 2015-04-30 Time 09:56 Rev Time 0.00
Received By rmcdouga Date 2015-04-30 Time 09:56 Sent To  
Notes
2015-04-30 09:54:53SEE REVIEWS FOR PERMIT #15030458.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-07-21 Cont ID  
Sent By rmcdouga Date 2015-07-21 Time 16:44 Rev Time 0.00
Received By rmcdouga Date 2015-07-21 Time 16:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2015-07-06 Cont ID  
Sent By albarran Date 2015-07-06 Time 18:02 Rev Time 0.00
Received By albarran Date 2015-07-06 Time 18:00 Sent To  
Notes
2015-07-06 18:02:34SEE UNIT REVIEWS UNDER PERMIT 15030458

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-04-30 Cont ID  
Sent By rmcdouga Date 2015-04-30 Time 09:54 Rev Time 0.00
Received By rmcdouga Date 2015-04-30 Time 09:54 Sent To  
Notes
2015-04-30 09:55:13SEE REVIEWS FOR PERMIT #15030458.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-07-21 Cont ID  
Sent By rmcdouga Date 2015-07-21 Time 16:44 Rev Time 0.00
Received By rmcdouga Date 2015-07-14 Time 07:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-07-09 Cont ID  
Sent By rmcdouga Date 2015-07-09 Time 17:38 Rev Time 0.00
Received By rmcdouga Date 2015-06-08 Time 07:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-04-30 Cont ID  
Sent By rmcdouga Date 2015-04-30 Time 15:06 Rev Time 0.00
Received By rmcdouga Date 2015-04-17 Time 09:10 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2015-07-09 Cont ID  
Sent By rmcdouga Date 2015-07-09 Time 14:30 Rev Time 0.00
Received By rmcdouga Date 2015-07-09 Time 14:30 Sent To  
Notes
2015-07-09 14:31:09MU 2015-16755, $58,620.00

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-04-30 Cont ID  
Sent By rmcdouga Date 2015-04-30 Time 09:55 Rev Time 0.00
Received By rmcdouga Date 2015-04-30 Time 09:55 Sent To  
Notes
2015-04-30 09:55:28SEE REVIEWS FOR PERMIT #15030458.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-07-21 Cont ID  
Sent By rmcdouga Date 2015-07-21 Time 16:44 Rev Time 0.00
Received By rmcdouga Date 2015-07-21 Time 16:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-07-09 Cont ID  
Sent By rmcdouga Date 2015-07-09 Time 17:38 Rev Time 0.00
Received By rmcdouga Date 2015-07-09 Time 17:35 Sent To  
Notes
2015-07-09 17:39:08SEE REVIEW COMMENTS FOR PERMIT #15030458.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-04-30 Cont ID  
Sent By rmcdouga Date 2015-04-30 Time 15:06 Rev Time 0.00
Received By rmcdouga Date 2015-04-30 Time 15:06 Sent To  
Notes
2015-04-30 15:06:04PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE ENERGY FORM IS MISSING THE FOLLOWING
 INFORMATION: OWNER, BUILDER NAME, PERMIT OFFICE ( CITY
 OF WEST PALM BEACH ), JURISDICTION ( 604700 ). FBC
 107.2.1.4
  
 2) THE ENERGY CALCULATIONS APPEAR TO HAVE USED AN
 INCORRECT ORIENTATION. THE 3080 FRONT DOOR DOOR FACES
 EAST NOT SOUTH AND THE 8' X 8' SGD ( 64 SQFT ) FACES
 WEST NOT NORTH.
  
 3) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE
 FRONT DOOR IS FOR A GLAZED SINGLE FRENCH DOOR WHERE THE
 GLASS AREA IS EQUAL OR GREATER THAN ONE THIRD OF THE
 DOOR AREA. THIS DOOR IS REQUIRED TO BE INCLUDED IN THE
 GLAZING CALCULATION AS A TOTAL FENESTRATION. FBC ENERGY
 SECTION 405.5.3
  
 4) ON THE MECHANICAL PLANS FOR THE MADERA MODELS THE
 14" RETURN TRANSFER DUCT IS TOO SMALL FOR THE MASTER
 BEDROOM SUITE. THERE ARE (2) 5", (1) 4" AND (1) 8"
 SUPPLY DUCTS ENTERING THE MASTER SUITE WITH A TOTAL
 CROSS SECTIONAL AREA OF 103". FBC-R M1602.4 REQUIRES
 THE TRANSFER DUCT TO BE 1.5 TIMES THE CROSS SECTIONAL
 AREA OF THE SUPPLY DUCTS ENTERING THE SUITE AND A ONE
 INCH UNDERCUT OF THE DOOR.
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-06-25 Cont ID  
Sent By tklarge Date 2015-06-25 Time 05:31 Rev Time 0.00
Received By tklarge Date 2015-06-25 Time 05:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-04-30 Cont ID  
Sent By rmcdouga Date 2015-04-30 Time 09:55 Rev Time 0.00
Received By rmcdouga Date 2015-04-30 Time 09:55 Sent To  
Notes
2015-04-30 09:55:40SEE REVIEWS FOR PERMIT #15030458.

Review Stop Z ZONING
Rev No 2 Status P Date 2015-06-15 Cont ID  
Sent By llouie Date 2015-06-15 Time 14:40 Rev Time 0.00
Received By llouie Date 2015-06-15 Time 14:40 Sent To  
Notes
2015-06-15 14:42:33ZONING APPROVED WITH THE FOLLOWING PROVISO:
  
 1.) DRIVEWAY SHALL BE SETBACK AT LEAST 3 FT. FROM THE
 INTERIOR SIDE PROPERTY LINE.
  
 * SEPARATE PERMIT REQUIRED FOR LANDSCAPING.
  
 CALL LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.

Review Stop Z ZONING
Rev No 1 Status F Date 2015-04-29 Cont ID  
Sent By linda Date 2015-04-29 Time 11:29 Rev Time 0.00
Received By llouie Date 2015-04-29 Time 11:29 Sent To  
Notes
2015-04-29 11:29:52** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) THE APPROVED PLAT FOR THE DEVELOPMENT SHALL BE
 REVIEWED BY ENGINEERING SERVICES AND RECORDED IN THE
 PUBLIC RECORDS OF PALM BEACH COUNTY PRIOR TO THE
 APPROVAL OF THIS PERMIT.
  
 2.) PROVIDE SETBACK DIMENSIONS FOR ALL STRUCTURAL
 ELEMENTS, INCLUDING BUT NOT LIMITED TO THE A/C UNIT,
 DRIVEWAY/STEPS, ETC.
  
 3.) AREA CALCULATIONS FOR UNIT REQUIRED IN PLANS.
  
 4.) SEPARATE REVIEW AND PERMIT APPLICATION REQUIRED FOR
 LANDSCAPING, DRIVEWAYS AND STEPS.
  
 PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS
 MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE
 @ (561) 822-1458 IF YOU HAVE QUESTIONS.
  
 ART IN PUBLIC PLACES REQUIREMENT:
  
 PURSUANT TO THE ART IN PUBLIC PLACES ORDINANCE NO.
 4504-14, AN ART ASSESSMENT FOR THE PROJECT IS REQUIRED.
 THE APPLICANT SHALL COMPLETE ONE OF THE FOLLOWING
 WITHIN NINETY (90) DAYS OF THE ISSUANCE OF THE FIRST
 BUILDING PERMIT:
  
 OPTION 1: SUBMIT DOCUMENTATION EVIDENCING THE ESCROW OF
 FUNDS FOR A WORK OF ART OR HISTORIC OR CULTURAL
 ELEMENTS VALUED IN AN AMOUNT OF ONE PERCENT OF THE
 TOTAL VERTICAL CONSTRUCTION COSTS IN COMPLIANCE WITH
 ORDINANCE NO. 4504-14 AND SUBMIT AN APPLICATION FOR
 APPROVAL OF THE WORK OF ART OR HISTORIC OR CULTURAL
 ELEMENTS.
  
 OPTION 2: CONTRIBUTE AN AMOUNT EQUAL TO ONE PERCENT OF
 THE TOTAL VERTICAL CONSTRUCTION COSTS FOR DEPOSIT TO
 THE ART IN PUBLIC PLACES FUND.
  
 *** UNLESS AN ALTERNATIVE DEADLINE IS ESTABLISHED IN A
 DEVELOPMENT ORDER, OR A TIME EXTENSION IS GRANTED BY
 THE DIRECTOR OF DEVELOPMENT SERVICES, NO CERTIFICATE OF
 OCCUPANCY FOR THE PROJECT SHALL BE ISSUED UNTIL THE
 ARTWORK IS INSTALLED, THE FINAL REVISED CONSTRUCTION
 COST AFFIDAVIT AND ACCOUNTING OF THE ESCROWED ART FUNDS
 HAS BEEN PROVIDED; AND/OR THE FULL ART ASSESSMENT HAS
 BEEN PAID TO THE CITY. ***
  
  