| Plan Review Stops For Permit 15030431 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2015-08-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-08-28 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-08-28 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2015-08-28 14:28:18 | APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED | | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | | DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL | | | RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF | | | RE-INSPECTION FEE(S). | | | 1) FBC - R 301.2.1.2 SUBMIT TWO COPIES OF INSTALLATION | | | SCHEDULES AND KEY PLANS FOR THE STORM PANELS. SPECIFY | | | THE OPENING SIZE, THE WIND PRESSURES, TYPE OF ANCHOR, | | | ANCHOR SPACING, EDGE DISTANCE, PANEL LENGTH, PANEL | | | SPAN, SEPARATION DISTANCE FROM PANEL TO GLASS AND THE | | | APPLICABLE SECTION NUMBER FROM THE INSTALLATION | | | DRAWINGS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2015-08-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-08-19 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-08-19 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2015-08-19 16:01:47 | PLAN REVIEW COMMENTS | | | 5TH REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PREVIOUS COMMENTS HAVE NOT BEEN ADDRESSED. SEE COMMENTS | | | BELOW. | | | | | | DENIED BY BUILDING - ( NOTE: THE PERMIT APPLICATION IS | | | MISSING FROM THE CONSTRUCTION DOCUMENTS. A NEW | | | REPLACEMENT APPLICATION IS REQUIRED. ) | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) REPEAT COMMENT. THE PLANS SPECIFY NEW IMPACT RATED | | | DOORS AND WINDOWS. FBC 107.3.4 - PROVIDE TWO SETS OF | | | PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE | | | REGULATED BY DCA RULE 9N-3 THAT HAVE BEEN REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE | | | TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS | | | INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN | | | PRESSURES FOR EACH OF THE WINDOW AND EXTERIOR DOOR | | | TYPES. ONLY ONE SET OF PRODUCT APPROVALS WAS SUBMITTED | | | FOR THE SINGLE HUNG WINDOWS (NOA NO. 14-0722.07). | | | | | | 2) REPEAT COMMENT. FBC - R 301.2.1.2 SUBMIT TWO COPIES | | | OF AN INSTALLATION SCHEDULE AND KEY PLAN FOR THE STORM | | | PANELS. SPECIFY THE OPENING SIZE, THE WIND PRESSURES, | | | TYPE OF ANCHOR, ANCHOR SPACING, EDGE DISTANCE, PANEL | | | LENGTH, PANEL SPAN, SEPARATION DISTANCE FROM PANEL TO | | | GLASS AND THE APPLICABLE SECTION NUMBER FROM THE | | | INSTALLATION DRAWINGS. I HAVE INCLUDED A LINK TO THE | | | CONSTRUCTION SERVICES DEPARTMENT SITE THAT HAS MANY OF | | | THE RELATED FORMS INCLUDING | | | THE SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE | | | DEVICES. | | | HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/ | | | | | | 3) THE REVISED PLANS AND THE RESPONSE LETTER INDICATE | | | THAT THE FRONT DOOR IS TO BE LARGE MISSILE IMPACT RATED | | | TO ALLOW FOR EGRESS WHEN THE STORM PANELS ARE IN PLACE | | | DURING THE THREAT OF A STORM PER FBC - R310.4. SUBMIT | | | TWO SETS OF PRODUCT APPROVALS FOR THE 3' 0" X 6' 8" | | | IMPACT RATED FRONT DOOR THAT HAVE BEEN REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE | | | TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS | | | INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN | | | PRESSURES. FBC 107.3.4 | | | | | | 4) ONE SET OF PRODUCT APPROVALS WERE PREVIOUSLY | | | SUBMITTED FOR EACH OF THE FOLLOWING NON-IMPACT RATED | | | DOORS FL#16106 AND A JELD-WEN CONTOURS PREMIUM STEEL | | | WOOD EDGE HALF LITE OUTSWING DOOR WITH NO FL# INDICATED | | | ON THE DOCUMENTS. TWO SETS OF PRODUCT APPROVALS WERE | | | SUBMITTED FOR NON-IMPACT RATED DOORS (FL#15255.13) WITH | | | THE LAST RESUBMITTAL. PLEASE CLARIFY WHICH OF THESE | | | WILL BE INSTALLED. AN ADDITIONAL SET OF PRODUCT | | | APPROVALS THAT HAVE BEEN REVIEWED BY THE DESIGNER OF | | | RECORD WILL BE REQUIRED IF YOU WISH TO USE THE FIRST | | | TWO MENTIONED AND A COVER SHEET WITH THE FL# IS | | | REQUIRED FOR THE HALF LITE DOOR. FBC 107.2.1 | | | | | | 5) THE PERMIT APPLICATION IS MISSING FROM THE | | | CONSTRUCTION DOCUMENTS. A NEW REPLACEMENT APPLICATION | | | IS REQUIRED. | | | | | | 6) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2015-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-29 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-29 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2015-07-29 16:56:38 | PLAN REVIEW COMMENTS | | | 4TH REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING - ( NOTE: THE PERMIT APPLICATION IS | | | MISSING FROM THE CONSTRUCTION DOCUMENTS. A NEW | | | REPLACEMENT APPLICATION IS REQUIRED. ) | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) REPEAT COMMENT. THE PLANS SPECIFY NEW IMPACT RATED | | | DOORS AND WINDOWS. FBC 107.3.4 - PROVIDE TWO SETS OF | | | PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE | | | REGULATED BY DCA RULE 9N-3 THAT HAVE BEEN REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE | | | TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS | | | INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN | | | PRESSURES FOR EACH OF THE WINDOW AND EXTERIOR DOOR | | | TYPES. ONLY ONE SET OF PRODUCT APPROVALS WAS SUBMITTED | | | FOR THE SINGLE HUNG WINDOWS (NOA NO. 14-0722.07). | | | | | | 2) REPEAT COMMENT. FBC - R 301.2.1.2 SUBMIT TWO COPIES | | | OF AN INSTALLATION SCHEDULE AND KEY PLAN FOR THE STORM | | | PANELS. SPECIFY THE OPENING SIZE, THE WIND PRESSURES, | | | TYPE OF ANCHOR, ANCHOR SPACING, EDGE DISTANCE, PANEL | | | LENGTH, PANEL SPAN, SEPARATION DISTANCE FROM PANEL TO | | | GLASS AND THE APPLICABLE SECTION NUMBER FROM THE | | | INSTALLATION DRAWINGS. I HAVE INCLUDED A LINK TO THE | | | CONSTRUCTION SERVICES DEPARTMENT SITE THAT HAS MANY OF | | | THE RELATED FORMS INCLUDING | | | THE SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE | | | DEVICES. | | | HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/ | | | | | | 3) THE REVISED PLANS AND THE RESPONSE LETTER INDICATE | | | THAT THE FRONT DOOR IS TO BE LARGE MISSILE IMPACT RATED | | | TO ALLOW FOR EGRESS WHEN THE STORM PANELS ARE IN PLACE | | | DURING THE THREAT OF A STORM PER FBC - R310.4. SUBMIT | | | TWO SETS OF PRODUCT APPROVALS FOR THE 3' 0" X 6' 8" | | | IMPACT RATED FRONT DOOR THAT HAVE BEEN REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE | | | TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS | | | INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN | | | PRESSURES. FBC 107.3.4 | | | | | | 4) ONE SET OF PRODUCT APPROVALS WERE PREVIOUSLY | | | SUBMITTED FOR EACH OF THE FOLLOWING NON-IMPACT RATED | | | DOORS FL#16106 AND A JELD-WEN CONTOURS PREMIUM STEEL | | | WOOD EDGE HALF LITE OUTSWING DOOR WITH NO FL# INDICATED | | | ON THE DOCUMENTS. TWO SETS OF PRODUCT APPROVALS WERE | | | SUBMITTED FOR NON-IMPACT RATED DOORS (FL#15255.13) WITH | | | THE LAST RESUBMITTAL. PLEASE CLARIFY WHICH OF THESE | | | WILL BE INSTALLED. AN ADDITIONAL SET OF PRODUCT | | | APPROVALS THAT HAVE BEEN REVIEWED BY THE DESIGNER OF | | | RECORD WILL BE REQUIRED IF YOU WISH TO USE THE FIRST | | | TWO MENTIONED AND A COVER SHEET WITH THE FL# IS | | | REQUIRED FOR THE HALF LITE DOOR. FBC 107.2.1 | | | | | | 5) THE PERMIT APPLICATION IS MISSING FROM THE | | | CONSTRUCTION DOCUMENTS. A NEW REPLACEMENT APPLICATION | | | IS REQUIRED. | | | | | | 6) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-07-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-07 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-07 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2015-07-06 19:27:53 | PLAN REVIEW COMMENTS | | | 3RD REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING - ( NOTE: THE PERMIT APPLICATION IS | | | MISSING FROM THE CONSTRUCTION DOCUMENTS. A NEW | | | REPLACEMENT APPLICATION IS REQUIRED. ) | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) REPEAT COMMENT. THE PLANS SPECIFY NEW IMPACT RATED | | | DOORS AND WINDOWS. FBC 107.3.4 - PROVIDE TWO SETS OF | | | PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE | | | REGULATED BY DCA RULE 9N-3 THAT HAVE BEEN REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE | | | TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS | | | INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN | | | PRESSURES FOR EACH OF THE WINDOW AND EXTERIOR DOOR | | | TYPES. ONLY ONE SET OF PRODUCT APPROVALS WAS SUBMITTED | | | AND TWO SETS ARE REQUIRED. | | | | | | 2)THE PRODUCT APPROVALS THAT WERE SUBMITTED ARE FOR | | | NON-IMPACT RATED WINDOWS AND GLAZED EXTERIOR DOORS. | | | SUBMIT PRODUCT APPROVALS FOR THE REQUIRED IMPACT | | | PROTECTION DEVICES. FBC-R301.2.1.2 | | | | | | 3) SUBMIT TWO COPIES OF A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. FBC 107.2.1 & | | | FBC-R301.2.1 | | | | | | 4) FBC-R310.4 REQUIRES AT LEAST ONE MEANS OF ESCAPE TO | | | BE PROVIDED WHILE STORM PANELS ARE IN PLACE DURING THE | | | THREAT OF A STORM. OCCUPANTS IN ANY PART OF THE | | | DWELLING SHALL BE ABLE TO ACCESS THE MEANS OF ESCAPE | | | WITHOUT PASSING THROUGH A LOCKABLE DOOR NOT UNDER THEIR | | | CONTROL. SHOW COMPLIANCE. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-26 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-26 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2015-05-26 10:17:31 | PLAN REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING - ( NOTE: THE PERMIT APPLICATION AND | | | OLD PLANS ARE MISSING FROM THIS RESUBMITTAL. ) | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) NEW COMMENT. BASED ON YOUR RESPOSE TO THE PREVIOUS | | | COMMENT, YOU INTEND TO BRING THE ILLEGALLY ENCLOSED | | | PORCHES INTO CODE COMPLIANCE. SUBMIT TWO COPIES OF | | | ENERGY CALCULATIONS TO SHOW THAT THE ENCLOSED PORCHES | | | COMPLY WITH THE 2010 FBC ENERGY CONSERVATION AND SEE | | | THE IMPACT FEE REVIEW STOP. | | | | | | 2) REPEAT COMMENT. THE VALUE OF $7500.00 SPECIFIED ON | | | THE APPLICATION IS LOW FOR THE WORK SHOWN ON THE PLANS. | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | 3) REPEAT COMMENT. THE PLANS SPECIFY NEW IMPACT DOORS | | | AND WINDOWS. FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT | | | APPROVALS FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3 THAT HAVE BEEN REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD. PROVIDE TWO COMPLETE | | | PRODUCT APPROVALS WITH FL OR NOA NUMBERS INCLUDING | | | INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES | | | FOR EACH OF THE DIFFERENT ROOFING MATERIALS, | | | WINDOW/GLASS TYPES, STRUCTURAL MULLIONS AND EXTERIOR | | | DOOR TYPES. | | | NEW COMMENT. THE PRODUCT APPROVALS THAT WERE SUBMITTED | | | ARE FOR NON-IMPACT RATED WINDOWS AND GLAZED EXTERIOR | | | DOORS. IF YOU WILL BE INSTALLING NON-IMPACT WINDOWS AND | | | DOORS, REVISE THE PLAN NOTES AND SUBMIT PRODUCT | | | APPROVALS FOR THE REQUIRED IMPACT PROTECTION | | | | | | 4) REPEAT COMMENT. SHOW COMPLIANCE WITH FBC R311.7.7 | | | AND R312 FOR GUARDS AND HANDRAILS ON THE DECK STAIRS. | | | NEW COMMENT.THE PLAN SPECIFIES THAT THE STAIRS HAVE 6 | | | RISERS. FBC-R311.7.7 REQUIRES HANDRAILS NOT LESS THAN | | | 34 INCHES OR MORE THAN 38 INCHES ON AT LEAST ONE SIDE | | | OF A FLIGHT OF STAIRS WITH FOUR OR MORE RISERS. | | | | | | 5) REPEAT COMMENT. SHOW COMPLIANCE WITH FBC-R314.3.1 | | | WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | NEW COMMENT. IN ADDITION TO THE SMOKE ALARMS REQUIRED | | | IN EACH SLEEPING ROOM, THEY ARE REQUIRED OUTSIDE EACH | | | SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE | | | BEDROOMS. | | | | | | 6) NEW COMMENT. THE TYPICAL EXTERIOR WALL SECTION ON | | | SHEET 5 SPECIFIES 6" BATT INSULATION WITH AN R-30 MIN. | | | INSULATION VALUE. THERE ARE NOT ANY 6 INCH THICK BATT | | | INSULATIONS THAT CAN PROVIDE A R-30 THERMAL RESISTANCE. | | | DEPENDING ON THE INSULATING MATERIAL USED, THE | | | THICKNESS REQUIRED TO ACHIEVE R-30 VARIES. YOU CAN | | | REVISE NOTE TO SAY MINIMUM R-30 BATT INSULATION. FBC | | | 107.2.1 | | | | | | 7) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-13 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-13 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2015-04-10 11:25:10 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) ACCORDING TO THE PALM BEACH COUNTY PROPERTY | | | APPRAISER THE MASTER BEDROOM, BATHROOM NO. 1 AND FOYER | | | ARE EITHER ENCLOSED OR OPEN PORCHES AND NOT CONSIDERED | | | HABITABLE SPACE. YOU WILL NEED TO SUBMIT DOCUMENTATION | | | TO SHOW THAT THE PORCHES WERE LEGALLY CONVERTED WITH | | | THE PROPER PERMITS AND INSPECTIONS. OTHERWISE, YOU WILL | | | HAVE TWO OPTIONS EITHER CONVERT THE AREAS BACK TO | | | PORCHES OR BRING THEM INTO COMPLIANCE WITH THE 2010 | | | FLORIDA BUILDING CODE AND 2008 NATIONAL ELECTRICAL | | | CODE. UNDER THE 2010 FBC EXISTING BUILDING THIS IS | | | CONSIDERED A CHANGE OF OCCUPANCY WITHOUT A CHANGE OF | | | OCCUPANCY CLASSIFICATION. IN ORDER FOR THESE AREAS TO | | | BE BROUGHT INTO COMPLIANCE, THEY WILL BE REQUIRED TO | | | COMPLY WITH CHAPTER 9 OF THE 2010 FBC EXISTING | | | BUILDING. THE FOLLOWING ITEMS WILL BE REQUIRED TO BE | | | MADE CODE COMPLIANT. THE STRUCTURE IN THESE AREAS ARE | | | REQUIRED TO MEET THE WINDLOAD REQUIREMENTS FOR THE | | | BUILDING ENVELOPE ( IN ADDITION TO GRAVITY LOADS), | | | PRODUCT APPROVALS FOR EXTERIOR DOORS AND WINDOWS, | | | EGRESS REQUIREMENTS, LIGHT AND VENTILATION, SMOKE AND | | | CARBON MONOXIDE ALARMS, FIRE SEPARATION REQUIREMENTS ( | | | SEPARATION DISTANCE AND ALLOWABLE OPENINGS), THE | | | REQUIREMENTS OF THE 2010 FBC ENERGY CONSERVATION, 2010 | | | FBCR MECHANICAL, THE REQUIREMENTS OF THE 2010 FBCR | | | PLUMBING AND THE ELECTRICAL SYSTEM IS REQUIRED TO | | | COMPLY WITH THE 2008 NATIONAL ELECTRIC CODE. THE PLANS | | | ARE REQUIRED TO BE REVIEWED BY PLAM BEACH COUNTY TO | | | DETERMINE IF IMPACT FEES ARE DUE. SPECIFY THE SQUARE | | | FOOTAGE OT THE EXISTING CONDITIONED SPACE AND THE | | | UNCONDITIONED SPACE (ILLEGALLY CONVERTED) ON THE PLANS. | | | | | | 2) THE VALUE OF $7500.00 SPECIFIED ON THE APPLICATION | | | IS LOW FOR THE WORK SHOWN ON THE PLANS. FBC 109.3 | | | BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE | | | WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | 3) THE PLANS HAVE AN ENGINEER'S TITLE BLOCK AND ARE | | | REQUIRED BY FS 471 & FAC 61G15 TO HAVE HIS SEAL AND | | | HANDWRITTEN SIGNATURE ON THEM. | | | | | | 4) THE PLANS SPECIFY NEW IMPACT DOORS AND WINDOWS. FBC | | | 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS FOR | | | THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF | | | THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES, | | | STRUCTURAL MULLIONS AND EXTERIOR DOOR TYPES. | | | | | | 5) SPECIFY THE TYPES AND SIZES OF THE WINDOWS THAT WILL | | | BE REPLACED. EXISTING BEDROOM EMERGENCY ESCAPE AND | | | RESCUE WINDOWS ARE REQUIRED TO COMPLY WITH FBC EXISTING | | | BUILDING 604.1 MEANS OF EGRESS FOR BUILDINGS UNDERGOING | | | ALTERATION SHALL COMPLY WITH THE REQUIREMENTS OF | | | SECTION 601.1 AND THE SCOPING PROVISIONS OF CHAPTER 1 | | | WHERE APPLICABLE. EXCEPTION: DOOR AND WINDOW | | | DIMENSIONS. IN RESIDENTIAL DWELLINGS AND DWELLING | | | UNITS, A MAXIMUM OF 5 PERCENT REDUCTION IN THE CLEAR | | | OPENING DIMENSIONS OF REPLACEMENT DOORS AND WINDOWS | | | SHALL BE ALLOWED. | | | | | | 6) THERE IS CONFLICTING INFORMATION ON SHEET 5. THE | | | EXTERIOR WALL SECTION SPECIFIES A WOOD FRAME WALL ON A | | | MONOLITHIC CONCRETE SLAB. THE DECK PLAN INDICATES THAT | | | THE EXISTING EXTERIOR WALL IS CBS AND PROBABLY HAS A | | | CRAWL SPACE SINCE THE DECK IS 3 FEET OFF THE GROUND. | | | PLEASE CLARIFY. FBC 107.2.1 | | | | | | 7) SHOW COMPLIANCE WITH FBC R311.7.7 AND R312 FOR | | | GUARDS AND HANDRAILS ON THE DECK STAIRS. | | | | | | 8) SPECIFY THE CONNECTORS THAT WILL BE USED TO ATTACH | | | THE 2 X 8 JOISTS TO THE 2 X 10 BEAMS AND 2 X 6 LEDGERS | | | AND THE 2 X 10 BEAMS TO THE 2 X 6 LEDGERS TO PROVIDE A | | | CONTINOUS LOAD PATH REQUIRED BY FBC-R 301.1 . | | | | | | 9) SPECIFY THE REQUIRED LIVE LOADS FOR THE PORCH ON THE | | | PROPOSED DECK ON THE PLANS. FBC-R301.5 | | | | | | 10) SHOW COMPLIANCE WITH FBC-R314.3.1 WHEN ALTERATIONS, | | | REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN | | | ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN | | | EXISTING DWELLINGS, THE INDIVIDUAL DWELLING UNIT SHALL | | | BE EQUIPPED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR | | | NEW DWELLINGS. | | | | | | 11) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-07-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-06 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-06 |
Time |
17:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-26 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-23 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2015-05-26 07:31:03 | PLAN REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRICAL | | | THE FOLLOWING COMMENTS FROM THE 1ST REVIEW WERE NOT | | | ADDRESSED. PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) NEC 210.52 (C) (1) - A RECEPTACLE OUTLET SHALL BE | | | INSTALLED AT EACH COUNTERTOP SPACE 12 INCHES OR WIDER | | | SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 2 | | | FEET MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN | | | THAT SPACE. | | | | | | 2) NEC 210.8 (A)(6) RECEPTACLES SERVING COUNTERTOP | | | SURFACES ARE REQUIRED TO BE GFCI PROTECTED. | | | | | | 3) NEC 210.12 (B) - OUTLETS ARE REQUIRED TO BE AFCI | | | PROTECTED. | | | | | | 4) NEC 406.11 - TAMPER-RESISTANT RECEPTACLES ARE | | | REQUIRED. | | | | | | 5) NEC 440.11 & 440.14 SHOW THE LOCATION OF THE | | | REQUIRED A/C EQUIPMENT DISCONNECTING MEANS ON THE | | | PLANS. | | | | | | 6) NEC 210.63 - PROVIDE A GFCI PROTECTED SERVICE OUTLET | | | FOR WITHIN 25' OF MECHANICAL EQUIPMENT. | | | | | | 7) THE CONDUIT AND WIRE SIZE FOR THE WEATHER HEAD SHOWN | | | ON THE SERVICE RISER PLAN IS INCORRECT. NEC 310.15 (B) | | | (6). | | | | | | 8) FBC-R314.3.1 WHEN ALTERATIONS, REPAIRS OR ADDITIONS | | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | | INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE | | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | R314.3 LOCATION. | | | SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING | | | LOCATIONS: | | | 1. IN EACH SLEEPING ROOM. | | | 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE | | | VICINITY OF THE BEDROOMS. | | | 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING | | | BASEMENTS AND HABITABLE ATTICS BUT NOT INCLUDING CRAWL | | | SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR | | | DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN | | | INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE | | | ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR | | | THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL | | | IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL. | | | WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE | | | INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM | | | DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT | | | THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE | | | ALARMS IN THE INDIVIDUAL UNIT. | | | | | | 9) SPECIFY THE LOCATION OF THE ELECTRIC METER AND | | | PANELS ON THE PLANS. FBC 107.2.1 | | | | | | 10) THE LUMINAIRES LOCATED IN THE BEDROOM CLOSETS SHALL | | | MEET THE REQUIREMENTS OF NEC 410. | | | | | | 11) FBC 107.2.1 - INFORMATION ON CONSTRUCTION | | | DOCUMENTS. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. THIS ITEM WAS | | | ADDRESSED. PLANS WERE SIGNED AND SEALED BY A FLORIDA | | | LICENSED ENGINEER. | | | | | | 12) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-05-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-13 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-13 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2015-04-13 17:12:52 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) NEC 210.52 (C) (1) - A RECEPTACLE OUTLET SHALL BE | | | INSTALLED AT EACH COUNTERTOP SPACE 12 INCHES OR WIDER | | | SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 2 | | | FEET MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN | | | THAT SPACE. | | | | | | 2) NEC 210.8 (A)(6) RECEPTACLES SERVING COUNTERTOP | | | SURFACES ARE REQUIRED TO BE GFCI PROTECTED. | | | | | | 3) NEC 210.12 (B) - OUTLETS ARE REQUIRED TO BE AFCI | | | PROTECTED. | | | | | | 4) NEC 406.11 - TAMPER-RESISTANT RECEPTACLES ARE | | | REQUIRED. | | | | | | 5) NEC 440.11 & 440.14 SHOW THE LOCATION OF THE | | | REQUIRED A/C EQUIPMENT DISCONNECTING MEANS ON THE | | | PLANS. | | | | | | 6) NEC 210.63 - PROVIDE A GFCI PROTECTED SERVICE OUTLET | | | FOR WITHIN 25' OF MECHANICAL EQUIPMENT. | | | | | | 7) THE CONDUIT AND WIRE SIZE FOR THE WEATHER HEAD SHOWN | | | ON THE SERVICE RISER PLAN IS INCORRECT. NEC 310.15 (B) | | | (6). | | | | | | 8) FBC-R314.3.1 WHEN ALTERATIONS, REPAIRS OR ADDITIONS | | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | | INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE | | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | R314.3 LOCATION. | | | SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING | | | LOCATIONS: | | | 1. IN EACH SLEEPING ROOM. | | | 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE | | | VICINITY OF THE BEDROOMS. | | | 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING | | | BASEMENTS AND HABITABLE ATTICS BUT NOT INCLUDING CRAWL | | | SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR | | | DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN | | | INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE | | | ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR | | | THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL | | | IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL. | | | WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE | | | INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM | | | DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT | | | THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE | | | ALARMS IN THE INDIVIDUAL UNIT. | | | | | | 9) SPECIFY THE LOCATION OF THE ELECTRIC METER ON THE | | | PLANS. FBC 107.2.1 | | | | | | 10) THE LUMINAIRES LOCATED IN THE BEDROOM CLOSETS SHALL | | | MEET THE REQUIREMENTS OF NEC 410. | | | | | | 11) FBC 107.2.1 - INFORMATION ON CONSTRUCTION | | | DOCUMENTS. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | 12) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2015-08-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-08-19 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-08-18 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2015-08-18 12:45:38 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-29 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-22 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2015-07-23 10:11:10 | RESUB ROUTED TO RMCDOUGAL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-07-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-07 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-19 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2015-06-19 08:25:56 | ROUTED TO ZONING/FORWARD TO MCDOUGAL/CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-26 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-07 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-13 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-11 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2015-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-29 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-29 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2015-07-29 14:31:00 | MU2015-17605, NO FEES WERE DUE |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-07-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-06 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-06 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2015-07-06 17:41:01 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-26 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-26 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2015-05-26 08:01:52 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-07-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-06 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-06 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2015-07-06 18:43:49 | RED-LINED PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-26 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-26 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2015-05-26 11:37:59 | PLAN REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC-R - M1401.3 SIZING. HEATING AND COOLING | | | EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS | | | CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER | | | APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. | | | PROVIDE EQUIPMENT SIZING CALCULATIONS. THE MECHANICAL | | | EQUIPMENT LISTED IN THE SCHEDULE ON SHEET 3 IS REQUIRED | | | TO MATCH THE SIZING CALCULATIONS. | | | NEW COMMENT. THE EQUIPMENT SCHEDULE ON SHEET 3 OF THE | | | PLANS DOES NOT MATCH THE ONE SPECIFIED IN THE SIZING | | | CALCULATIONS. THE PLAN SPECIFIES A TRANE WITH A 14.5 | | | SEER AND THE LOAD CALCS. HAVE A GOODMAN, JANITROL, | | | AMANA DISTI... WITH A 16 SEER. THE EQUIPMENT SCHEDULE | | | COLUMN HEADER FOR SEER HAS 16 SEER WITH 14.5 LISTED AS | | | THE SEER FOR THE TRANE UNIT. | | | | | | 2) FBC-R - M 1602.4 PROVIDE BALANCED AIR RETURN AT | | | BEDROOMS. SPECIFY THE SIZES OF THE RETURN AIR TRANSFER | | | GRILLS ON THE MECHANICAL PLAN. TRANSFER GRILLES SHALL | | | USE 50 SQUARE INCHES (OF GRILLE AREA) TO 100 CFM (OF | | | SUPPLY AIR) FOR SIZING THROUGH-THE-WALL TRANSFER | | | GRILLES AND USING AN UNRESTRICTED 1 INCH UNDERCUTTING | | | OF DOORS TO ACHIEVE PROPER RETURN AIR BALANCE. | | | HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET THESE | | | REQUIREMENTS FOR PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY ROOMS, | | | EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE SHALL | | | BE INCLUDED. | | | NEW COMMENT. SHEET 3 OF THE PLANS SPECIFIES 8 X 8 | | | TRANSFER GRILLS (64 SQUARE INCHES) WHICH IS ONLY ENOUGH | | | FOR 128 CFM. ALL OF THE BEDROOMS HAVE MORE CFMS THAN | | | THIS. | | | | | | 3) NEW COMMENT. THERE IS ANOTHER MECHANICAL PLAN | | | INCLUDED WITH THE ENERGY CALCULATIONS THAT DOES NOT | | | MATCH THE ONE ON SHEET 3 OF THE PLANS. THE FOLLOWING | | | COMMENTS ADDRESS THAT DRAWING. THERE IS NO EQUIPMENT | | | SCHEDULE, THE SIZE OF THE SUPPLY GRILLS ARE NOT | | | SPECIFIED, THE SIZE OF THE RETURN GRILL IN THE HALLWAY | | | IS NOT SPECIFIED, THE SIZE OF THE RETURN TRANSFER DUCTS | | | AT BEDROOMS 1 AND 2 ARE NOT SPECIFIED AND THE NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | REMOVE THE MECHANICAL PLANS THAT WILL NOT BE USED. FBC | | | 107.2.1 | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-13 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-13 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2015-04-13 14:31:24 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC-R - M1401.3 SIZING. HEATING AND COOLING | | | EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS | | | CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER | | | APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. | | | PROVIDE EQUIPMENT SIZING CALCULATIONS. THE MECHANICAL | | | EQUIPMENT LISTED IN THE SCHEDULE ON SHEET 3 IS REQUIRED | | | TO MATCH THE SIZING CALCULATIONS. | | | | | | 2) FBC-R - M 1602.4 PROVIDE BALANCED AIR RETURN AT | | | BEDROOMS. SPECIFY THE SIZES OF THE RETURN AIR TRANSFER | | | GRILLS ON THE MECHANICAL PLAN. TRANSFER GRILLES SHALL | | | USE 50 SQUARE INCHES (OF GRILLE AREA) TO 100 CFM (OF | | | SUPPLY AIR) FOR SIZING THROUGH-THE-WALL TRANSFER | | | GRILLES AND USING AN UNRESTRICTED 1 INCH UNDERCUTTING | | | OF DOORS TO ACHIEVE PROPER RETURN AIR BALANCE. | | | HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET THESE | | | REQUIREMENTS FOR PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY ROOMS, | | | EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE SHALL | | | BE INCLUDED. | | | | | | 3) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | 4) THE PLANS SHOW THE AIRHANDLER LOCATED IN A CLOSET. | | | IF THE RETURN IS THROUGH A LOUVERED DOOR, SPECIFY THAT | | | ON THE PLANS. FBC 107.2 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-07-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-07-06 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-07-06 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2015-07-06 17:43:13 | RED-LINED THE PLANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2015-05-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2015-05-23 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-23 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2015-05-23 12:10:10 | REDLINED PLANS. FBC-R P3104.3 EVERY DRY VENT CONNECTING | | | TO A HORIZONTAL DRAIN SHALL CONNECT ABOVE THE CENTER | | | LINE OF THE HORIZONTAL DRAIN PIPE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-04-04 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-04-04 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-04-04 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2015-04-04 07:47:23 | A CODE COMPLIANT SANITARY RISER SHALL BE SUBMITTED FOR | | | REVIEW PRIOR TO ROUGH PLUMBING INSP. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-06-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-06-19 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-06-19 |
Time |
09:33 |
Sent To |
B |
|
| Notes |
| 2015-06-19 09:34:44 | 6/19/15 | | | | | | DRIVEWAY PERMIT REQUIRES SEPARATE PERMIT, YOU MUST | | | REMOVE SOME OF THE PAVERS, YOU MUST MAINTAIN 75% OR | | | 1000 SQUARE FEET OF LANDSCAPING IS REQUIRED IN THE | | | FRONT SETBACK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-05-11 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-05-11 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-05-11 |
Time |
08:03 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-03-20 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-03-20 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-03-20 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2015-03-19 15:39:02 | 3/19/15 |
|
|