Plan Review Details - Permit 15030314
| Plan Review Stops For Permit 15030314 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2015-03-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-03-13 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-03-13 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2015-03-13 13:11:05 | REVISION REQUIRED TO REROUTE PE PIPE FROM UNDER SLAB AT | | | ROOFED PATIO AREA. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2015-03-11 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-03-11 |
Time |
06:36 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-03-11 |
Time |
04:04 |
Sent To |
|
|
| Notes |
| 2015-03-11 06:09:07 | 1) SHT. P-1 NOTES A TOTAL BTU LOAD OF 1,039,000 BUT MY | | | CALCULATIONS COME TO 1,264,00 INCLUDING THE EXISTING | | | GENERATOR. TABLE 402.4 (20) SHOWS THE MAXIMUM BTU LOAD | | | ON 3/4" PE PIPE AT 2 PSI AT 200 FT. IS 736,000 ( THERE | | | IS NO ROW FOR 185 FT.). THE SIZE OF THE PE LINE FROM | | | THE POINT OF CONNECTION AT THE METER UP TO THE TEE FOR | | | THE GAS RANGE SHALL BE 1" ( THE 60 FT. SECTION) | | | 2) THE 1/2" GALVANIZED DROP TO THE RANGE SHALL BE 3/4" | | | PER TABLE 402.4 (2) OF 2010 FUEL GAS CODE. THE MAXIMUM | | | BTU LOAD ON 1/2" SCH. 40 PIPE @ 60 FT. IS 65,000 BTU'S. | | | 3) SIZE THE LINE FROM THE POOL HEATER REGULATOR TO THE | | | NEW POOL HEATER. IF IT IS SCH. 40 METAL IT SHALL BE 1" | | | PER TABLE 402.4 (2) OF THE FUEL GAS CODE. | | | 4) SHOW THE LINE SIZES AND PIPE MATERIAL FROM THE | | | MEDIUM PRESSURE REGULATORS TO THE APPLIANCES WHERE | | | NEEDED. | | | 5) NOTE # 12 ON SHT. P-1 NOTES THAT PE PIPE WILL BE | | | INSTALLED OUTSIDE UNDERGROUND ONLY BUT THE PLAN CLEARLY | | | SHOWS THE PIPE GOING UNDER THE SLAB TO THE NEW GAS | | | GRILL. CLARIFY. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-03-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-03-13 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-03-13 |
Time |
13:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-03-11 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-03-11 |
Time |
06:36 |
Rev Time |
|
| Received By |
tklarge |
Date |
2015-03-09 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-03-10 06:22:30 | SENT TO PLUMBING BOX<$5K. |
|
|
|