| Plan Review Stops For Permit 15030301 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-08-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-21 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-21 |
Time |
07:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-07-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-07-22 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-07-22 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2015-07-22 08:51:56 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15030301 | | | ADD: 3805 S OLIVE AVE. | | | CONT: DELTA MG | | | TEL: ( 561)239-4947 | | | E-MAIL:[email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: WED. JULY 22/ 2015 | | | ACTION: BUILDING PROVISO | | | | | | 1) THE SUBMITTED REPORT FOR WHISPER MAT FLOOR | | | UNDERLAYMENT WITH A IIC RATING OF 49 TESTED TO ASTM E | | | 492 TO MEET THE REQUIRED IIC RATING OF 50 A DOUBLE | | | LAYER OF 3 1/2 INCHES OF INSULATION TO BE INSTALLED | | | BETWEEN JOIST. THIS WAS DISCUSSED WITH ASSISTANT B. O. | | | DOUG HARVEY AND OK'ED. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-04-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-04-27 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-04-27 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2015-04-27 15:52:26 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15030301 | | | ADD: 3805 S OLIVE AVE. | | | CONT: DELTA MG | | | TEL: ( 561)239-4947 | | | E-MAIL:[email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: MON. APRIL 27/ 2015 | | | ACTION: DENIED | | | | | | 1-3) COMPLIED> | | | | | | 4) 2ND REQUEST. SEMI- COMPLIED. THE (3) REPORTS | | | SUBMITTED FOR WHISPER MAT: | | | | | | 4A) COMPLIED. SURFACE BURNING CHARACTERISTICS OF | | | BURNING MATERIALS ASTM E 84 : FLAME SPREAD 0 & SMOKE | | | DEVELOPED INDEX 0. | | | | | | 4B) SEMI-COMPLIED. THE SOUND TRANSMISSION LOSS TEST, | | | ASTM E-90, WITH A STC= 57 DB. THE SYSTEM THAT WAS | | | TESTED PAGE 2 OF 4 LIST THE COMPONENTS THAT MAKE UP THE | | | TESTED ASSEMBLY, 1/4 IN. GLAZED TILE, 1/4 IN. POLYMER | | | MODIFIED THIN SET, 2.5 MM (0.1 IN.), 5/8 IN. B. C. | | | PLYWOOD, 3/4 IN. T & G OSB SUB-FLOOR, 3 1/2 IN. X 18 | | | IN. X 12 FT. OPEN WEB TRUSSES, RESILIENT FURRING | | | CHANNEL, 3 1/2 IN. OF FIBERGLASS INSULATION BATTS & 1 | | | LAYER OF 5/8 IN. TYPE C WALLBOARD. | | | SITE CONDITIONS WRITTEN ON THE FACE OF THE TEST REPORT | | | 2X12 TRUSSES, (FLOOR JOIST/ I LOIST?) 5/8 PLYWOOD PLUS | | | 1/2 IN. DUROCK. THE TESTED ASSMBLY HAS A 5/8 IN. B. C. | | | FINISH PLYWOOD + 3/4 IN. OSB OPEN WEB JOIST, RESILIENT | | | CHANNEL FURRING. PLEASE PROVIDE RANIONAL ANALYSIS AND | | | PREFORM A ENGINEERED JUDGEMENT AS WHAT IT WILL TAKE TO | | | MEET THE EQUIVALENCY OF THE TESTING. WE UNDERSTAND THAT | | | YOU WILL NOT FIND A TESTED REPORT WITH THE SAME | | | COMONENTS AS THE TEST SPECIMEN FOR THE WOOD PRODUCTS | | | AND WITH DURAROCK AS A COMPONENT, PLEASE BE SPECIFIC AS | | | TO HOW EACH OF THE MEMBERS ARE TO BE EITHER FASTENED | | | AND OR ADHERRED TO EACH OTHER. | | | | | | 4C) THE SUBMITTED REPORT FOR WHISPER MAT FLOOR | | | UNDERLAYMENT WITH A IIC RATING OF 49 TESTED TO ASTM E | | | 492 DOES NOT MEET THE REQUIRED IIC RATING OF 50. | | | AS STATED ABOVE THE TESTED ASSEMBLY IN THIS CASE DID | | | NOT MEET THE REQUIREMENTS OF THE CODE WITH THE SAME | | | CONFIGURATION. PLEASE PROVIDE RANIONAL ANALYSIS AND | | | PREFORM A ENGINEERED JUDGEMENT AS WHAT IT WILL TAKE TO | | | MEET THE REQUIREMENT OF ASTM E-492 WITH A IIC OF 50 DB | | | MINIMUM. WE UNDERSTAND THAT YOU WILL NOT FIND A TESTED | | | REPORT WITH THE SAME COMONENTS AS THE TEST SPECIMEN FOR | | | THE WOOD PRODUCTS AND WITH DURAROCK AS A COMPONENT, | | | PLEASE BE SPECIFIC AS TO HOW EACH OF THE MEMBERS ARE TO | | | BE EITHER FASTENED AND OR ADHERRED TO EACH OTHER. | | | ------------------------------------------------------- | | | ------------------------------------------------------- | | | ------------------------------------------------------- | | | ------------------------------- | | | 4) 1ST REVIEW COMMENTS. 2010 1207.3 STRUCTURE BORN | | | SOUND REPORT FOR PROFLEX . PLEASE PROVIDE THE SLAB | | | THICKNESS. THIS REPORT DECLARES A IIC RATING OF 68DB | | | WHEN APPLIED TO A 8 INCH SLAB AND A 5/8 IN DROP CEILING | | | WITH 3 1/2 INCHES OF FIBERGLASS INSULATION (0.16PSF). | | | PLEASE IDENTIFY THE ACTUAL FLOOR/ CEILING ASSEMBLY TO | | | SEE IF THIS REPORT IS THE RIGHT CONFIGURATION, NOTE | | | DROPED CEILINGS WOULD NEED TO BE THROUGH THE WHOLE UNIT | | | WITH A 10 INCH PLENUM. 1207.3 STRUCTURE-BORNE SOUND. | | | | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561) 805-6715 | | | FAX: (561)805-6676 | | | E-MAIL: [email protected] | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-03-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-03-13 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-03-13 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2015-03-13 07:50:23 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15030301 | | | ADD: 3805 S OLIVE AVE. | | | CONT: DELTA MG | | | TEL: ( 561)239-4947 | | | E-MAIL:[email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: MON. APRIL 27/ 2015 | | | ACTION: DENIED | | | | | | 1-3) COMPLIED> | | | | | | 4) 2ND REQUEST. SEMI- COMPLIED. THE (3) REPORTS | | | SUBMITTED FOR WHISPER MAT: | | | | | | 4A) COMPLIED. SURFACE BURNING CHARACTERISTICS OF | | | BURNING MATERIALS ASTM E 84 : FLAME SPREAD 0 & SMOKE | | | DEVELOPED INDEX 0. | | | | | | 4B) SEMI-COMPLIED. THE SOUND TRANSMISSION LOSS TEST, | | | ASTM E-90, WITH A STC= 57 DB. THE SYSTEM THAT WAS | | | TESTED PAGE 2 OF 4 LIST THE COMPONENTS THAT MAKE UP THE | | | TESTED ASSEMBLY, 1/4 IN. GLAZED TILE, 1/4 IN. POLYMER | | | MODIFIED THIN SET, 2.5 MM (0.1 IN.), 5/8 IN. B. C. | | | PLYWOOD, 3/4 IN. T & G OSB SUB-FLOOR, 3 1/2 IN. X 18 | | | IN. X 12 FT. OPEN WEB TRUSSES, RESILIENT FURRING | | | CHANNEL, 3 1/2 IN. OF FIBERGLASS INSULATION BATTS & 1 | | | LAYER OF 5/8 IN. TYPE C WALLBOARD. | | | SITE CONDITIONS WRITTEN ON THE FACE OF THE TEST REPORT | | | 2X12 TRUSSES, (FLOOR JOIST/ I LOIST?) 5/8 PLYWOOD PLUS | | | 1/2 IN. DUROCK. THE TESTED ASSMBLY HAS A 5/8 IN. B. C. | | | FINISH PLYWOOD + 3/4 IN. OSB OPEN WEB JOIST, RESILIENT | | | CHANNEL FURRING. PLEASE PROVIDE RANIONAL ANALYSIS AND | | | PREFORM A ENGINEERED JUDGEMENT AS WHAT IT WILL TAKE TO | | | MEET THE EQUIVALENCY OF THE TESTING. WE UNDERSTAND THAT | | | YOU WILL NOT FIND A TESTED REPORT WITH THE SAME | | | COMONENTS AS THE TEST SPECIMEN FOR THE WOOD PRODUCTS | | | AND WITH DURAROCK AS A COMPONENT, PLEASE BE SPECIFIC AS | | | TO HOW EACH OF THE MEMBERS ARE TO BE EITHER FASTENED | | | AND OR ADHERRED TO EACH OTHER. | | | | | | 4C) THE SUBMITTED REPORT FOR WHISPER MAT FLOOR | | | UNDERLAYMENT WITH A IIC RATING OF 49 TESTED TO ASTM E | | | 492 DOES NOT MEET THE REQUIRED IIC RATING OF 50. | | | AS STATED ABOVE THE TESTED ASSEMBLY IN THIS CASE DID | | | NOT MEET THE REQUIREMENTS OF THE CODE WITH THE SAME | | | CONFIGURATION. PLEASE PROVIDE RANIONAL ANALYSIS AND | | | PREFORM A ENGINEERED JUDGEMENT AS WHAT IT WILL TAKE TO | | | MEET THE REQUIREMENT OF ASTM E-492 WITH A IIC OF 50 DB | | | MINIMUM. WE UNDERSTAND THAT YOU WILL NOT FIND A TESTED | | | REPORT WITH THE SAME COMONENTS AS THE TEST SPECIMEN FOR | | | THE WOOD PRODUCTS AND WITH DURAROCK AS A COMPONENT, | | | PLEASE BE SPECIFIC AS TO HOW EACH OF THE MEMBERS ARE TO | | | BE EITHER FASTENED AND OR ADHERRED TO EACH OTHER. | | | ------------------------------------------------------- | | | ------------------------------------------------------- | | | ------------------------------------------------------- | | | ------------------------------- | | | 4) 1ST REVIEW COMMENTS. 2010 1207.3 STRUCTURE BORN | | | SOUND REPORT FOR PROFLEX . PLEASE PROVIDE THE SLAB | | | THICKNESS. THIS REPORT DECLARES A IIC RATING OF 68DB | | | WHEN APPLIED TO A 8 INCH SLAB AND A 5/8 IN DROP CEILING | | | WITH 3 1/2 INCHES OF FIBERGLASS INSULATION (0.16PSF). | | | PLEASE IDENTIFY THE ACTUAL FLOOR/ CEILING ASSEMBLY TO | | | SEE IF THIS REPORT IS THE RIGHT CONFIGURATION, NOTE | | | DROPED CEILINGS WOULD NEED TO BE THROUGH THE WHOLE UNIT | | | WITH A 10 INCH PLENUM. 1207.3 STRUCTURE-BORNE SOUND. | | | | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561) 805-6715 | | | FAX: (561)805-6676 | | | E-MAIL: [email protected] | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-09-17 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-17 |
Time |
18:46 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-17 |
Time |
17:59 |
Sent To |
I |
|
| Notes |
| 2015-09-17 19:22:50 | SO AS NOT TO HOLD THE PERMIT FROM BEING ISSUED, THIS | | | APPLICATION IS BEING APPROVED WITH THE FOLLOWING | | | PROVISOS: | | | 1. IF THE CORNER AREA BEHIND THE KITCHEN SINK IS 12 | | | INCHES OR GREATER AS SPECIFIED IN NEC 210.52(C), IT | | | SHALL HAVE AN OUTLET. | | | 2. EACH CONDENSING UNIT SHALL HAVE WITHIN 25' A SERVICE | | | OUTLET AS REQUIRED BY NEC 210.63. THIS OUTLET SHALL BE | | | SERVED FROM THE RESPECTIVE UNIT'S ELECTRIC SERVICE. | | | I CAN SUGGEST GE MODEL # TFN60RGFRCP, 60 AMP 240-VOLT | | | NON-FUSE AC DISCONNECT WITH GFCI RECEPTACLE OR | | | EQUIVALENT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-08-20 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-08-20 |
Time |
19:03 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-08-20 |
Time |
18:38 |
Sent To |
B |
|
| Notes |
| 2015-08-20 19:16:33 | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS | | | EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE | | | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO | | | THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE | | | CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW. | | | | | | 1. ACCORDING TO A LETTER FROM MR. DANILO ALCANTARA, | | | EACH SUB WILL SUBMIT THEIR OWN DRAWING AND THEREFORE | | | APPLY FOR THEIR OWN PERMIT. THE FOLLOWING REVIEW IS FOR | | | THE DRAWING PRESENTLY SUBMITTED, THOUGH IF THIS | | | STATEMENT IS TRUE, THE RESULTS OF THIS REVIEW WILL | | | DIFFER. PLEASE ADVISE IF THE PREVIOUSLY SUBMITTED | | | LETTER ATTESTING TO THIS REMAINS IN EFFECT. | | | 2. THE WORD "ROMEX" AS USED IN THIS NOTE IS TO IDENTIFY | | | A TYPE OF CABLE. ROMEX IS A BRAND NAME AND NOT A TYPE | | | OF CABLE, REFER TO CABLE TYPES "NM", "NMC" OR "NMS". | | | 3. THE TITLE BLOCK INDICATES THAT THIS IS A 4 PLEX | | | REMODEL. THE SUBMITTED DRAWING IS INCOMPLETE. IT | | | REFLECTS ONLY TWO UNITS. | | | 4. YOU SHALL SUBMIT A SITE SPECIFIC RISER DIAGRAM | | | 5. YOU SHALL PROVIDE SITE SPECIFIC LOAD CALCS FOR EACH | | | UNIT AND THEN THE FOR THE SINGLE SERVICE FOR THE | | | MULTI-UNIT DWELLING. | | | 6. AS CIRCUIT DIRECTORY AS DESCRIBED IN NEC 408.4 SHALL | | | BE SUBMITTED FOR EACH UNIT. | | | 7. EVERY CEILING LUMINAIRE OUTLET SHALL BE LISTED TO | | | SUPPORT A MINIMUM OF 50 LBS. AS INDICATED IN NEC 314.27 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-04-09 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2015-04-09 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2015-04-09 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-06-08 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-06-08 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-06-08 |
Time |
12:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-03-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-03-19 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-03-19 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2015-03-19 14:12:59 | SINGLE HUNG WINDOWS NOT APPROPRIATE ON MID-CENTURY | | | STYLE. FHM SPOKE TO CONTARCTOR AND RECOMMENDED | | | CASEMENT. NEED FRAME AND GLAZING COLOR CONFIRMED. | | | QUESTIONS CONTACT FRIEDERIKE MITTNER, CITY HISOTRIC | | | PRESERVATION PLANNER AT 822-1457. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2015-09-17 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-09-17 |
Time |
19:23 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-09-17 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2015-09-17 19:25:44 | 9/17/15 - PASSED ELECTRICAL REVIEW W/PROVISOS. | | | CONTRACTOR NOTIFIED VIA EMAIL. SENT TO SMALL READY BIN | | | "D". MA | | 2015-09-17 16:00:24 | RESUB ROUTED TO MALBARRAN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-08-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-08-21 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-08-18 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2015-08-18 16:03:41 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-07-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-07-22 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-07-20 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2015-07-20 13:33:38 | CCOLE DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-08-18 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-07-22 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-04-24 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-04-11 |
Time |
11:03 |
Rev Time |
|
| Received By |
hmoser |
Date |
2015-03-09 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-03-09 17:12:11 | SENT TO B-15. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2015-08-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-08-19 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-08-19 |
Time |
06:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2015-07-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-07-20 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-07-20 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2015-07-20 14:48:51 | 2ND REVIEW: FBC 2010 MECHANICAL | | | | | | 1) SHOW THE BRANCH DUCT SIZES ON THE PLAN. | | | 2) THE 16X6" TRANSFER GRILL IS UNDERSIZED FOR 287 | | | CFM'S- SEE SECTION 601.4 FBC-10 MECHANICAL. | | | 3) PROVIDE TIE DOWN ENGINEERING FOR ANCHORING THE | | | CONDENSERS TO THE PADS- SECTION 301.12. | | | 4) SHOW THE LOCATIONS OF ALL FOUR CONDENSERS ON THE | | | PLANS- ONLY ONE OF THE FOUR IS SHOWN. | | | 5) THE PLAN INDICATES A 3/8" CONDENSATE PIPE, MINIMUM | | | 3/4" IS REQUIRED- SECTION 307. | | | | | | | | | | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-05-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-05-29 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-05-29 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2015-05-29 13:00:05 | 3RD MECHANICAL REVIEW. | | | | | | 1) AS PREVIOUSLY REQUESTED, PLEASE SUBMIT AC PLANS AND | | | SPECIFICATIONS, AND A MECHANICAL SUB-PERMIT. THIS IS | | | PER THE PLAN NOTES INDICATING NEW AC AND A DROP CEILING | | | IN THE HALL FOR DUCTWORK. | | | | | | CHRISTOPHER COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-04-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-04-11 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-04-11 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2015-04-11 11:03:41 | NOTE SAY REFER TO AIR CONDITIONING | | | PLAN. NO AIR CONDITIONING PLAN | | | SUBMITTED AT THIS TIME | | | REVIEW BY HM. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-04-04 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-04-04 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-04-04 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-03-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-03-19 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-03-19 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2015-03-10 13:59:22 | 3/10/15 |
|
|