Plan Review Details - Permit 15030194
Plan Review Stops For Permit 15030194
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-03-11 Cont ID  
Sent By tklarge Date 2015-03-11 Time 10:23 Rev Time 0.00
Received By tklarge Date 2015-03-11 Time 10:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-03-09 Cont ID  
Sent By tklarge Date 2015-03-09 Time 09:35 Rev Time 0.00
Received By tklarge Date 2015-03-09 Time 05:58 Sent To  
Notes
2015-03-09 09:08:001) PLEASE SUBMIT A PLAN AND A DESCRIPTION ON THE
 APPLICATION THAT CLEARLY REFLECTS THE SCOPE OF WORK TO
 BE DONE.WPB AMEND. TO 2010 FL. BLDG. CODE SEC. 107.2.1.
 2) SHOW THE LOCATION OF THE KITCHEN ON THE PLANS.WPB
 AMEND. TO 2010 FL. BLDG. CODE SEC. 107.2.1.
 3) SUBMIT MANUF. INSTALLATION INSTRUCTIONS FOR THE
 INSTALLATION OF THE DUROCK. 2010 FBCR SEC.R702.4.2.
 4) PLANS REFER TO THE REPLACING OF STUDS. SUBMIT PLANS
 THAT INDICATE WHERE THE STUDS ARE BEING REPLACED. SHOW
 IF STUDS BEING REPLACED ARE IN AN INTERIOR OR AN
 EXTERIOR WALL. SHOW HOW THE STUDS WILL BE CONNECTED TO
 THE TOP AND BOTTOM PLATES TO PROVIDE A CONTINUOUS LOAD
 PATH PER 2010 FBCR SEC.301.1 &.2010 FBCR SEC.602.
 5) INDICATE IF DRYWALL WILL BE REPLACED ON THE
 CEILINGS.WPB AMEND. TO 2010 FL. BLDG. CODE SEC.
 107.2.1.
 6) SUBMIT DETAILS FOR THE WIDENING OF THE DOOR. SUBMIT
 FRAMING DETAILS. WPB AMEND. TO 2010 FL. BLDG. CODE SEC.
 107.2.1.
 7) IF THE STUDS BEING REPLACED ARE IN AN EXTERIOR WALL,
 INDICATE IF ANY EXTERIOR SIDING IS BEING REPLACED.
 8) IDENTIFY THE SPECIFIC WALLS WHERE THE DRYWALL IS
 BEING REPLACED.WPB AMEND. TO 2010 FL. BLDG. CODE SEC.
 107.2.1.
 9) ARE THE KITCHEN SINK AND CABINETS ALSO BEING
 REPLACED? INDICATE ON THE PLAN.WPB AMEND. TO 2010 FL.
 BLDG. CODE SEC. 107.2.1.
 10) INDICATE THE WIDTH OF THE NEW DOOR AND THE
 THICKNESS OF THE DRYWALL BEING APPLIED THROUGHOUT.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-03-11 Cont ID  
Sent By tklarge Date 2015-03-11 Time 10:24 Rev Time 0.00
Received By tklarge Date 2015-03-10 Time 17:47 Sent To  
Notes
2015-03-10 17:48:10RE-SUBMITTAL SENT TO TIM LARGE FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-09 Cont ID  
Sent By tklarge Date 2015-03-09 Time 09:37 Rev Time 0.00
Received By tklarge Date 2015-03-05 Time 16:28 Sent To  
Notes
2015-03-05 16:28:20TO PLUMBING
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-03-11 Cont ID  
Sent By tklarge Date 2015-03-11 Time 10:16 Rev Time 0.00
Received By tklarge Date 2015-03-11 Time 06:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-03-09 Cont ID  
Sent By tklarge Date 2015-03-09 Time 09:36 Rev Time 0.00
Received By tklarge Date 2015-03-09 Time 09:36 Sent To  
Notes
2015-03-06 13:45:301) INDICATE ON THE PLAN IF THE FIXTURES ARE BEING
 REPLACED IN JUST ONE BATHROOM OR BOTH BATHROOMS.IF JUST
 ONE BATH, IDENTIFY WHICH BATHROOM IS BEING DONE. THE
 DESCRIPTION OF WORK ON THE APPLICATION NOTES'REPLACE
 TUB/BATH/SINK/DRYWALL" WHICH IS VAGUE.
 2) ARE THE KITCHEN SINK AND CABINETS BEING REPLACED?
 INDICATE ON THE PLANS.
 3) THE PLAN SHOWS A WASHER & DRYER IN BATHROOM
 #2.CLARIFY.
 4) SHOW THE LOCATION OF THE KITCHEN ON THE PLAN. WPB
 AMEND. TO 2010 FL. BLDG. CODE SEC. 107.2.1.
 5) PLEASE SUBMIT A PLAN AND A DESCRIPTION ON THE
 APPLICATION THAT CLEARLY REFLECTS THE SCOPE OF WORK TO
 BE DONE.WPB AMEND. TO 2010 FL. BLDG. CODE SEC. 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  