| Plan Review Stops For Permit 15030170 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-06-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-15 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-15 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2015-06-15 14:55:09 | APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED | | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | | DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL | | | RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF | | | RE-INSPECTION FEE(S). | | | 1) SUBMIT ROOF TRUSS DRAWINGS THAT HAVE BEEN DESIGNED | | | FOR EXPOSURE C. FBC-R301.2.1 | | | 2) SUBMIT PRODUCT APPROVALS FOR THE THERMA TRU FIBER | | | CLASSIC EXTERIOR DOOR (FL 8871.5) THAT IS LISTED IN THE | | | PRODUCT APPROVAL SUBMITTAL AFFIDAVIT ON THE COVERSHEET. | | | FBC 107.2.1 & DCA RULE 9N-3 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-06-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-08 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-08 |
Time |
18:51 |
Sent To |
|
|
| Notes |
| 2015-06-08 18:51:26 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE EXPOSURE CATEGORY ON SHEET 1 WAS NOT CHANGED | | | FROM "B" TO "C". FBC-R301.2.1.4 | | | | | | 2) THE COMPONENT AND CLADDING PRESSURES WERE NOT | | | CHANGED TO REFLECT THE CHANGE TO EXPOSURE "C". | | | FBC-R301.2.1 | | | | | | 3) THE NEGATIVE DESIGN PRESSURE FOR THE ONE CAR GARAGE | | | DOOR IS INCORRECTLY SPECIFIED AS -334.0 PSF. PLEASE | | | CORRECT. | | | | | | 4) SUBMIT TRUSS DRAWINGS FOR EXPOSURE "C" THAT HAVE | | | BEEN REVIEWED AND APPROVED BY THE DESIGNER OF RECORD. | | | FBC-R802.1.6.1 & FAC 61G15 - 31.003 | | | | | | 5) THE PRODUCT APPROVALS FOR THE CONCRETE ROOF TILE | | | LISTS SEVERAL ATTACHMENT METHODS. SPECIFY THE SPECIFIC | | | METHOD THAT WILL BE USED TO INSTALL THE TILE AND RESIST | | | THE OVERTURN MOMENT. FBC 107.2.1 AND FBC-R905.3 | | | | | | 6) IN ORDER TO AVOID ADDITIONAL REVIEW COMMENTS, PLEASE | | | REVIEW THE PRODUCT APPROVALS THAT WERE SUBMITTED TO | | | VERIFY THAT THE DESIGN PRESSURES LISTED IN THE PRODUCT | | | APPROVAL WILL MEET THE EXPOSURE "C" COMPONENT AND | | | CLADDING PRESSURES. FBC-R301.2.1 | | | | | | 7) THE VALUE OF WORK WAS INCREASED FROM $106,460.00 TO | | | $212,875.00 BASED ON ICC VALUATION DATA. FBC 109.3 | | | | | | 8) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-28 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-28 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2015-04-28 18:41:31 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE EXPOSURE CATEGORY ON SHEET 1 WAS NOT CHANGED | | | FROM "B" TO "C". FBC-R301.2.1.4 | | | | | | 2) THE COMPONENT AND CLADDING PRESSURES WERE NOT | | | CHANGED TO REFLECT THE CHANGE TO EXPOSURE "C". | | | FBC-R301.2.1 | | | | | | 3) THE NEGATIVE DESIGN PRESSURE FOR THE ONE CAR GARAGE | | | DOOR IS INCORRECTLY SPECIFIED AS -334.0 PSF. PLEASE | | | CORRECT. | | | | | | 4) SUBMIT TRUSS DRAWINGS FOR EXPOSURE "C" THAT HAVE | | | BEEN REVIEWED AND APPROVED BY THE DESIGNER OF RECORD. | | | FBC-R802.1.6.1 & FAC 61G15 - 31.003 | | | | | | 5) THE PRODUCT APPROVALS FOR THE CONCRETE ROOF TILE | | | LISTS SEVERAL ATTACHMENT METHODS. SPECIFY THE SPECIFIC | | | METHOD THAT WILL BE USED TO INSTALL THE TILE AND RESIST | | | THE OVERTURN MOMENT. FBC 107.2.1 AND FBC-R905.3 | | | | | | 6) IN ORDER TO AVOID ADDITIONAL REVIEW COMMENTS, PLEASE | | | REVIEW THE PRODUCT APPROVALS THAT WERE SUBMITTED TO | | | VERIFY THAT THE DESIGN PRESSURES LISTED IN THE PRODUCT | | | APPROVAL WILL MEET THE EXPOSURE "C" COMPONENT AND | | | CLADDING PRESSURES. FBC-R301.2.1 | | | | | | 7) THE VALUE OF WORK WAS INCREASED FROM $106,460.00 TO | | | $212,875.00 BASED ON ICC VALUATION DATA. FBC 109.3 | | | | | | 8) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-06-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-12 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-12 |
Time |
07:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-28 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-28 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2015-04-28 18:41:39 | SEE REVIEW COMMENTS FOR PERMIT # 15030165. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-06-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-15 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-15 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-06-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-12 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-26 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-28 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-20 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2015-06-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-15 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-15 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2015-06-15 14:59:35 | MU 2015 - 14120 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-06-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-12 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-12 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2015-06-12 07:24:23 | SEE PREVIOUS COMMENTS. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-28 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-28 |
Time |
18:42 |
Sent To |
|
|
| Notes |
| 2015-04-28 18:41:48 | SEE REVIEW COMMENTS FOR PERMIT # 15030165. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-06-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-12 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-12 |
Time |
07:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-04-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-28 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-28 |
Time |
18:33 |
Sent To |
|
|
| Notes |
| 2015-04-28 18:33:49 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE ENERGY FORM IS MISSING THE FOLLOWING | | | INFORMATION: OWNER, BUILDER NAME, PERMIT OFFICE ( CITY | | | OF WEST PALM BEACH ), JURISDICTION ( 604700 ). FBC | | | 107.2.1.4 | | | | | | 2) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE | | | FRONT DOOR IS FOR A GLAZED SINGLE FRENCH DOOR WHERE THE | | | GLASS AREA IS EQUAL OR GREATER THAN ONE THIRD OF THE | | | DOOR AREA. THIS DOOR IS REQUIRED TO BE INCLUDED IN THE | | | GLAZING CALCULATION AS A TOTAL FENESTRATION. FBC ENERGY | | | SECTION 405.5.3 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-06-10 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-06-10 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-06-10 |
Time |
13:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-04-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-04-12 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-04-12 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2015-04-12 10:26:48 | 1) SUBMIT A WATER RISER FOR THE DIFFERENT MODELS. WPB | | | AMEND. TO 2010 FBC SEC. 107.3.5.3. | | | 2) THE LANDSCAPE PLAN SHOWS THE WATER SUPPLY FOR THE | | | IRRIGATION SYSTEM AS CITY WATER. THE IRRIGATION SYSTEM | | | SHALL BE PROTECTED AGAINST BACKFLOW PER THE CITY'S | | | CROSS CONNECTION MANUAL. CONTACT STEVEN HUNTER AT | | | 561-805-2240 FOR THE PROPER TYPE OF BACKFLOW DEVICE TO | | | BE INSTALLED. | | | 3) THE WATER HEATERS IN THE GARAGES SHALL BE PROTECTED | | | FROM VEHICLE IMPACT. | | | 4) SHOW THE LOCATION OF THE CONTROLLER AND RAIN SENSOR | | | FOR THE IRRIGATION SYSTEM. A RAIN SENSOR IS REQUIRED ON | | | THE IRRIGATION SYSTEM PER FL. STATUTE 373.62. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2015-06-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-06-29 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-06-29 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2015-06-29 09:30:29 | BORAL TILESEAL UNDERLAYMENT NOA NO.12-0417.06 | | | HANSON REGAL/SPANISH "S" II CONCRETE ROOF TILE NOA NO. | | | 12-0917.08 INSTALLED WITH (2) #8 SCREWS | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-05-29 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2015-05-29 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2015-05-29 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2015-05-29 13:21:51 | ZONING APPROVED WITH THE FOLLOWING PROVISO: | | | | | | 1.) DRIVEWAY SHALL BE SETBACK AT LEAST 3 FT. FROM THE | | | SIDE INTERIOR PROPERTY LINE(S). | | | | | | * SEPARATE PERMIT REQUIRED FOR LANDSCAPING. | | | | | | CALL LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-03-31 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2015-03-31 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2015-03-31 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2015-03-31 11:49:19 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) PROVIDE THE FOLLOWING DIMENSIONS IN THE SITE | | | PLAN/SURVEY FOR BUILDING 8: FRONT SETBACK FOR LOT 43; | | | WIDTH OF DRIVEWAYS. | | | | | | 2.) SEPARATE PERMIT APPLICATION AND REVIEW REQUIRED FOR | | | LANDSCAPE PLAN. | | | | | | 3.) FINAL PLAT MUST BE APPROVED AND RECORDED PRIOR TO | | | ZONING APPROVAL OF PERMIT. | | | | | | PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS | | | MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE | | | @ (561) 822-1458 IF YOU HAVE QUESTIONS. | | | | | | ART IN PUBLIC PLACES REQUIREMENT: | | | | | | PURSUANT TO THE ART IN PUBLIC PLACES ORDINANCE NO. | | | 4504-14, AN ART ASSESSMENT FOR THE PROJECT IS REQUIRED | | | SINCE THE VALUE OF NEW BUILDING CONSTRUCTION | | | ($1,950,000) EXCEED THE VALUE OF $500,000. THE | | | APPLICANT SHALL COMPLETE ONE OF THE FOLLOWING WITHIN | | | NINETY (90) DAYS OF THE ISSUANCE OF THE FIRST BUILDING | | | PERMIT: | | | | | | OPTION 1: SUBMIT DOCUMENTATION EVIDENCING THE ESCROW OF | | | FUNDS FOR A WORK OF ART OR HISTORIC OR CULTURAL | | | ELEMENTS VALUED IN AN AMOUNT OF ONE PERCENT OF THE | | | TOTAL VERTICAL CONSTRUCTION COSTS IN COMPLIANCE WITH | | | ORDINANCE NO. 4504-14 AND SUBMIT AN APPLICATION FOR | | | APPROVAL OF THE WORK OF ART OR HISTORIC OR CULTURAL | | | ELEMENTS. | | | | | | OPTION 2: CONTRIBUTE AN AMOUNT EQUAL TO ONE PERCENT OF | | | THE TOTAL VERTICAL CONSTRUCTION COSTS FOR DEPOSIT TO | | | THE ART IN PUBLIC PLACES FUND. | | | | | | *** UNLESS AN ALTERNATIVE DEADLINE IS ESTABLISHED IN A | | | DEVELOPMENT ORDER, OR A TIME EXTENSION IS GRANTED BY | | | THE DIRECTOR OF DEVELOPMENT SERVICES, NO CERTIFICATE OF | | | OCCUPANCY FOR THE PROJECT SHALL BE ISSUED UNTIL THE | | | ARTWORK IS INSTALLED, THE FINAL REVISED CONSTRUCTION | | | COST AFFIDAVIT AND ACCOUNTING OF THE ESCROWED ART FUNDS | | | HAS BEEN PROVIDED; AND/OR THE FULL ART ASSESSMENT HAS | | | BEEN PAID TO THE CITY. *** | | | |
|
|