Plan Review Details - Permit 15030118
Plan Review Stops For Permit 15030118
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-03-31 Cont ID  
Sent By skennedy Date 2015-03-31 Time 10:34 Rev Time 0.00
Received By skennedy Date 2015-03-31 Time 10:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-03-16 Cont ID  
Sent By skennedy Date 2015-03-16 Time 15:44 Rev Time 0.00
Received By skennedy Date 2015-03-16 Time 15:44 Sent To  
Notes
2015-03-16 15:49:511ST REVIEW: FBC 2010
  
 THE $1,500.00 VALUE IS LOW. REVISE TO INCLUDE THE BELOW
 AND FLOORING.
  
 FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 PROVIDE TEST DATA FOR FLOORING UNDERLAYMENT FOR THE
 EXISTING FLOOR SLAB CONDITION TO DEMONSTRATE COMPLIANCE
 WITH THE SECTIONS BELOW:
  
 FBC 603.1 FLAME SPREAD
  
 FBC 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-03-16 Cont ID  
Sent By skennedy Date 2015-03-16 Time 15:53 Rev Time 0.00
Received By skennedy Date 2015-03-16 Time 15:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-03-09 Cont ID  
Sent By scaldero Date 2015-03-09 Time 12:09 Rev Time 0.00
Received By scaldero Date 2015-03-09 Time 12:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-03-31 Cont ID  
Sent By skennedy Date 2015-03-31 Time 10:34 Rev Time 0.00
Received By skennedy Date 2015-03-27 Time 07:15 Sent To  
Notes
2015-03-28 07:16:15SENT TO S KENNEDY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-16 Cont ID  
Sent By skennedy Date 2015-03-16 Time 15:53 Rev Time 0.00
Received By skennedy Date 2015-03-04 Time 15:33 Sent To  
Notes
2015-03-04 15:42:11R10

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-03-16 Cont ID  
Sent By skennedy Date 2015-03-16 Time 15:53 Rev Time 0.00
Received By skennedy Date 2015-03-16 Time 15:52 Sent To  
Notes
***NONE***