Plan Review Details - Permit 15030101
Plan Review Stops For Permit 15030101
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-04-16 Cont ID  
Sent By skennedy Date 2015-04-16 Time 10:15 Rev Time 0.00
Received By skennedy Date 2015-04-16 Time 10:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-03-06 Cont ID  
Sent By jwitmer Date 2015-03-06 Time 09:03 Rev Time 0.00
Received By jwitmer Date 2015-03-06 Time 09:00 Sent To  
Notes
2015-03-06 09:03:41BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15030101
 ADD: 5801 EARNEST ST.
 CONT: SABRE COMMUNICATIONS
 TEL: (712)258-6690
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE
  
 1ST REVIEW
 DATE: FRI. MARCH 06/ 2015
 ACTION: DENIED
  
 1) NOTE THERE WERE (3) SETS OF CIVIL PLANS SUBMITTED
 BUT ONLY (1) SET OF THE MANUFACTURED BLDG. PLANS
 SUBMITTED TO THE BUILDING DEPARTMENT. 2010 WEST PALM
 BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER
 1, ADMINISTRATION 107.2.1.3: PLEASE SUBMIT 2 OF ALL
 SURVEYS, PLANS, REPORTS, REVISIONS, PRODUCT APPROVALS
 AND OR SUBMITTALS FOR REVIEW FOR PERMIT.
  
 2) THE PLANS SUBMITTED FOR A CONCRETE SHELTER BY SABRE
 INDUCTRIES DOES NOT HAVE A STAMP THEY ARE PART OF THE
 STATE APPROVED MODULAR BUILDING PROGRAM. THEY HAVE TO
 MEET THE REQUIREMENTS OF FLORIDA STATE STATUTE
 553.35-553.42 PART I FOR MANUFACTURED BUILDINGS .
  
 3) SHEET S-1 FROM B+T ENGINEERING FOUNDATION NOTE # 3
 INDICATES VAPOR BARRIER BEFORE CONCRETE BUT THERE IS NO
 CODE COMPLIANCE WITH 2010 FBC-B 1816.1 TERMITE
 PROTECTION.
  
 4) SHEET S1-2 FROM B+T ENGINEERING ALSO DOES NOT
 PROVIDE THE WIND DESIGN FOR THE SLAB AND THE BUILDING
 THAT WILL BE ATTACHED TO THIS SLAB. 1609.3 BASIC WIND
 SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
  
 4.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
  
 4.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
  
 4.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
  
 4.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 4.5) COMPONENTS & CLADDING PRESSURES POSITIVE &
 NEGATIVE TABLE 1609.2(2) ASCE 7-10.
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561) 805-6715
 FAX: (561)805-6676
 E-MAIL: [email protected]
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-03-30 Cont ID  
Sent By sciard Date 2015-03-30 Time 13:54 Rev Time 0.00
Received By sciard Date 2015-03-30 Time 13:54 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2015-04-08 Cont ID  
Sent By cranford Date 2015-04-08 Time 15:52 Rev Time 0.00
Received By cranford Date 2015-04-08 Time 15:50 Sent To  
Notes
2015-04-08 15:52:11PER JONATHAN ORAVETZ EMAIL: I COMPLETED A SITE
 INSPECTION OF THE PROPOSED TOWER FOOTPRINT ON APRIL 24,
 2014 TO EXAMINE THE AREA FOR JURISDICTIONAL WETLANDS.
 THE BASIS OF REVIEW MET ALL APPLICABLE STATE (CHAPTER
 62-340, F.A.C) AND FEDERAL (TITLE 33 CODE OF FEDERAL
 REGULATIONS) REGULATIONS IN REGARDS TO DETERMINATION OF
 WETLANDS. PER THE STATE-WIDE ENVIRONMENTAL PERMITTING
 (SWERP) RULES ISSUED ON OCTOBER 1, 2013; ALL STATE ERP
 REGULATORY AGENCIES INCLUDING THE SFWMD NOW FOLLOW THE
 REVISED SWERP. THEREFORE, OUR BASIS OF REVIEW WILL
 SATISFY COMPLIANCE WITH CURRENT STATE REGULATORY BASIS
 OF REVIEW.
  
 NO STATE OF FEDERALLY JURISDICTIONAL WETLANDS WERE
 IDENTIFIED ONSITE, AS REPORTED IN THE FCC NEPA REVIEW
 SUMMARY REPORT DATED JULY 23, 2014.
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2015-03-30 Cont ID  
Sent By cranford Date 2015-03-30 Time 15:12 Rev Time 0.00
Received By cranford Date 2015-03-30 Time 15:06 Sent To Z
Notes
2015-03-30 15:11:48PUBLIC WORKS DEPT.
  
 PLEASE INDICATE HOW THE PROJECT - CONSTRUCTION OF AN
 ACCESS ROAD, GUY WIRE PADS, AND GUYED TOWER PAD - WILL
 COMPLY WITH SECTION 94-375 OF THE CODE OF ORDINANCES.
 PLEASE SHOW THE LOCATION AND EXTENT OF ANY WETLANDS ON
 THE CONSTRUCTION PLANS.
  
 PLEASE SHOW THE PROPOSED LOCATION OF THE EROSION AND
 SEDIMENT CONTROL MEASURES (SILT FENCE).
  
 KELLY CRANFORD, PE
 CITY LAND DEVELOPMENT ENGINEER
 [email protected]
 561-494-1098 (OFFICE)
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-03-05 Cont ID  
Sent By pleduc Date 2015-03-05 Time   Rev Time 0.00
Received By pleduc Date 2015-03-05 Time 11:36 Sent To  
Notes
2015-03-05 11:43:34THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PROVIDE THE APPLICABLE FIRE EXTINGUISHERS PER NFPA 10,
 I.E.10LB ABC AND C RATED FOR ELECTRICAL EQUIPMENT, IN
 AN EASILY ACCESSIBLE AND VISIBLE LOCATION.
  
 PROVIDE KNOX PADLOCK AT GATE FOR 24HR FIRE DEPARTMENT
 ACCESS.
  
 PROVIDE KNOX BOX AND ACCESS KEYS AT BUILDING FOR 24HR
 FIRE DEPARTMENT ACCESS.
  
 THE FUEL TANK AND GENERATOR INSTALL SHALL BE UNDER
 SEPARATE PERMITS.
  
 PROVIDE THE HAZARD PLACARD AND NO SMOKING SIGNAGE AT
 THE TANK AND GENERATOR AS APPLICABLE
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2015-04-02 Cont ID  
Sent By skennedy Date 2015-04-02 Time 14:57 Rev Time 0.00
Received By skennedy Date 2015-04-02 Time 14:57 Sent To  
Notes
2015-04-02 14:58:18GAS WILL BE BY SEPARATE SUBMITTAL.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-04-02 Cont ID  
Sent By skennedy Date 2015-04-02 Time 14:58 Rev Time 0.00
Received By skennedy Date 2015-03-03 Time 17:56 Sent To  
Notes
2015-03-03 17:57:08C36

Review Stop Z ZONING
Rev No 2 Status P Date 2015-04-06 Cont ID  
Sent By ajones Date 2015-04-06 Time 12:19 Rev Time 0.00
Received By ajones Date 2015-04-06 Time 12:19 Sent To  
Notes
2015-04-06 12:21:204/6/15- PASSED WITH THE PROVISION THAT A SEPARATE
 PERMIT IS REQUIRED FOR THE FENCE, LANDSCAPING AND
 GENERATOR PRIOR TO THE A CO BEING ISSUED FOR THE
 BUILDING.
  
 ANGELLA JONES, PLANNING AND ZONING ADMINISTRATOR
 561-822-1441
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2015-04-02 Cont ID  
Sent By jroach Date 2015-04-02 Time 09:47 Rev Time 0.00
Received By jroach Date 2015-04-02 Time 09:47 Sent To  
Notes
2015-04-02 09:47:32ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 04.02.2015
 PERMIT NO.: 15030101
 ADDRESS: 5801 EARNEST
 CONTRACTOR/CONTACT: JASON BLACK
 TELEPHONE NO.: 712.258.6690
 SCOPE OF REVIEW: MODULAR BUILDING FOR COMMUNICATIONS
 TOWER.
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. ALL EQUIPMENT COMPOUNDS SHALL BE ENCLOSED BY A SOLID
 OPAQUE FENCE OR WALL. CHAIN LINK, CHAIN LINK WITH
 SLATS, OR CHAIN LINK WITH FABRIC SCREENING, IS NOT
 ACCEPTABLE. SEPARATE PERMIT APPLICATIONS SHALL BE
 SUBMITTED FOR THE FENCE/WALL.
  
 2. PRIOR TO THE REMOVAL OF ANY TREES, A TREE ALTERATION
 PERMIT SHALL BE OBTAINED FROM THE DEVELOPMENT SERVICES
 DEPARTMENT ? PLANNING DIVISION.
  
 3. ADDITIONAL INFORMAITON SHALL BE PROVIDED REGARDING
 THE GENERATOR, PROPANE TANK, ETC. SPECIFICALLY, WHAT IS
 THE HEIGHT OF EACH. THEY WILL NEED TO BE ADEQUATELY
 SCREENED BY THE ABOVE-METIONED OPAQUE WALL/FENCE.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1448
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.WPB.ORG
  
2015-03-10 13:46:043/10/15


Account Summary | Usage Policy | Privacy Policy