Plan Review Details - Permit 15030079
Plan Review Stops For Permit 15030079
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-04-22 Cont ID  
Sent By shill Date 2015-04-22 Time 16:10 Rev Time 0.00
Received By shill Date 2015-04-22 Time 16:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-04-01 Cont ID  
Sent By shill Date 2015-04-01 Time 18:15 Rev Time 0.00
Received By shill Date 2015-04-01 Time 18:15 Sent To  
Notes
2015-04-01 18:27:07****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 COMMENTS FROM PREVIOUS LIST:
  
 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET
 AT
  
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/SCHEDULE_FOR_INSTALLATION.PDF
  
 2ND REVIEW - THE PRODUCT APPROVAL IS EXPIRED (FBC 2007
 RATHER THAN FBC 2010). THE INSTALLATION SCHEDULE CANNOT
 BE REVIEWED UNTIL THE CORRECT PRODUCT APPROVAL IS
 PROVIDED. HOWEVER, PLEASE NOTE THE FOLLOWING:
  
 SEE PAGE 5 OF THE PRODUCT APPROVAL, AND OTHER ANCHOR
 CHARTS. A 3 1/2" EDGE DISTANCE IS REQUIRED FOR THIS
 PRODUCT APPROVAL, BUT 3" SPECIFIED ON THE INSTALLATION
 SCHEDULE.
  
 SEE PAGE 5 OF THE PRODUCT APPROVAL, AND OTHER ANCHOR
 CHARTS. FASTENER SHOULD CORRELATE WITH THE CHARTS. NOTE
 THAT TAPCON IS NOT ALLOWED FOR SOME OF THE ANCHOR
 TYPES. INSTALLATION SCHEDULE STATES THAT THIS IS CB
 SUBSTRATE.
 HORIZONTAL INSTALLATION IS TYPICALLY CB OR GROUT FILLED
 CELLS (IF THIS IS AN OPTION ON THE PRODUCT APPROVAL),
 VERTICAL INSTALLATIONS ARE USUALLY CONCRETE TOP, BLOCK
 BOTTOM.
  
 SHUTTER CONNECTION MOUNTING TYPE SHOULD CORRELATE WITH
 THE ANCHOR CHARTS. SEE PAGE 5 AND OTHER SHEETS. THE
 MOUNTING TYPES IN THIS PRODUCT APPROVAL ARE NAMED 1
 (TOP), 1 (BOTTOM) THROUGH 8 (TOP), 8 (BOTTOM). SHEETS 2
 THROUGH 4 PROVIDE DETAILS OF THE MOUNTING TYPES.
  
 SPAN SHOULD BE ONE DIMENSION (DISTANCE ANCHOR TO
 ANCHOR).
  
 2. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4.
 INCLUDE THE ROOM DESIGNATION.
  
 THE "EGRESS" SHOWN ON THE PLAN HAS SHUTTERS PROPOSED.
 GARAGE ROLL UP DOOR CANNOT BE EMERGENCY MEANS OF ESCAPE
 AND RESCUE.
  
 3. OK
  
 4. PROVIDE THE FLORIDA STATE PRODUCT APPROVAL COVER
 PAGE. THIS WILL INCLUDE THE NUMBER AND STATUS (SHOULD
 BE "APPROVED").
  
 THE PRODUCT APPROVAL PROVIDED IS EXPIRED (FBC 2007).
 PROVIDE A CURRENT PRODUCT APPROVAL (FBC 2010).
  
 TWO COMPLETE, COLLATED SETS OF PLANS REQUIRED FOR
 PERMIT ISSUANCE.
  
 5. ALTHOUGH THE OWNER'S AND CONTRACTOR'S SIGNATURES
 HAVE BEEN NOTARIZED, NEITHER HAS SIGNED ON THE LINE FOR
 THE SIGNATURE. COUNTY INFORMATION FOR OWNER IS BLANK.
 PLEASE SEE FS117.
  
  
 IMPORTANT NOTICE: COMING SOON IN 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-03-14 Cont ID  
Sent By shill Date 2015-03-14 Time 12:35 Rev Time 0.00
Received By shill Date 2015-03-14 Time 12:35 Sent To  
Notes
2015-03-14 12:36:39****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET
 AT
  
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/SCHEDULE_FOR_INSTALLATION.PDF
  
 2. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4.
 INCLUDE THE ROOM DESIGNATION.
  
 3. PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS WILL
 BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH THE
 INSTALLATION SCHEDULE, ITEM 1 ABOVE. FBC R301, FBC1609,
 FBC*106.
  
 4. PROVIDE THE FLORIDA STATE PRODUCT APPROVAL COVER
 PAGE. THIS WILL INCLUDE THE NUMBER AND STATUS (SHOULD
 BE "APPROVED").
  
 TWO COMPLETE, COLLATED SETS OF PLANS REQUIRED FOR
 PERMIT ISSUANCE.
  
 5. ALTHOUGH THE OWNER'S AND CONTRACTOR'S SIGNATURES
 HAVE BEEN NOTARIZED, NEITHER HAS SIGNED ON THE LINE FOR
 THE SIGNATURE. COUNTY INFORMATION FOR OWNER IS BLANK.
 PLEASE SEE FS117.
  
  
 IMPORTANT NOTICE: COMING SOON IN 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-04-22 Cont ID  
Sent By shill Date 2015-04-22 Time 16:10 Rev Time 0.00
Received By shill Date 2015-04-14 Time 07:53 Sent To  
Notes
2015-04-15 07:53:55RE-SUBMITTAL SENT TO SAMANTHA HILL FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-04-01 Cont ID  
Sent By shill Date 2015-04-01 Time 18:27 Rev Time 0.00
Received By shill Date 2015-03-20 Time 07:36 Sent To  
Notes
2015-03-20 07:37:06TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-14 Cont ID  
Sent By shill Date 2015-03-14 Time 12:36 Rev Time 0.00
Received By shill Date 2015-03-14 Time 12:36 Sent To  
Notes
2015-03-03 13:01:35ROUTED TO BUILDING OVER $5K