Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2015-06-15 Cont ID  
Sent By skennedy Date 2015-06-15 Time 14:45 Rev Time 0.00
Received By skennedy Date 2015-06-15 Time 14:45 Sent To  
Notes
2015-06-15 14:45:58PER ENGINEERING & ZONING, THIS IS NOT A PARKING AREA.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-04-29 Cont ID  
Sent By skennedy Date 2015-04-29 Time 14:58 Rev Time 0.00
Received By skennedy Date 2015-04-29 Time 14:58 Sent To  
Notes
2015-04-29 15:02:311ST REVIEW: FBC 2010
  
 FBC 107 SHOW ACCESSIBLE PARKING AND ACCESSIBLE ROUTE.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-04-01 Cont ID  
Sent By shill Date 2015-04-01 Time 07:14 Rev Time 0.00
Received By shill Date 2015-03-31 Time 18:18 Sent To  
Notes
2015-04-01 07:17:06****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FROM PREVIOUS LIST:
  
 1. PLANS TO BE ARCHITECTURAL QUALITY TO SCALE. ONE
 APPLICATION (15030034) IS FOR "MINOR DRYWALL REPAIR"
 BUT NOTHING ON PLAN SHOWING SCOPE / LOCATION. THERE
 SHOULD BE AN EXISTING AND PROPOSED PLAN. APPLICATION TO
 INCLUDE ALL WORK INCLUDED IN THE VIOLATION ISSUED. FBC
 107
  
 2ND REVIEW, NOTE STATES "MINOR DRYWALL REPAIRS (HOLES)"
 - DOES NOT SHOW LOCATIONS. IF A PART OF A FIRE RATED
 TENANT SEPARATION WALL, A DETAIL WILL BE REQUIRED. PER
 INSPECTOR AND PHOTOGRAPHS OF THE JOB, DRYWALL REPAIR
 WAS MORE EXTENSIVE THAN INDICATED ON THE PLANS. SCOPE
 ALSO INCLUDED WALL FRAMING. SEE FIRST LIST; PROVIDE AN
 ARCHITECTURAL PLAN WHICH SHOWS WORK STARTED WITHOUT
 PERMIT.
  
 2. OK
  
 NEW COMMENT:
  
 3. VALUE TOO LOW. PROVIDE A REASONABLE VALUE OR A
 VALUATION WILL BE DETERMINED FOR YOU, FBC 109.
  
 4. THE RESUBMITTAL SHEET STATES THAT ASPHALT WILL BE
 REPLACED WITH GRASS AND PAVERS. A FENCE SKETCH WAS
 PROVIDED. BOTH REQUIRE SEPARATE PERMITS.
  
 5. THE NEW PLAN SHOWS TILE FLOORS. IS THIS EXISTING OR
 PROPOSED? IF PROPOSED, TEST REPORTS REQUIRED FOR 2ND
 FLOOR UNITS:
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 IF A SUSPENDED CEILING WAS USED AS A PART OF THE TEST,
 PROVIDE INFORMATION AS TO HOW IT HAS BEEN DETERMINED
 THAT THIS CONDITION CURRENTLY EXISTS AND HOW IT CAN BE
 GUARANTEED THAT THE CONDITIONS IN THE UNIT BELOW WILL
 NOT BE ALTERED.
  
 PLEASE PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. IF A SUSPENDED CEILING WAS USED AS A PART
 OF THE TEST, PROVIDE INFORMATION AS TO HOW IT HAS BEEN
 DETERMINED THAT THIS CONDITION CURRENTLY EXISTS AND HOW
 IT CAN BE GUARANTEED THAT THE CONDITIONS IN THE UNIT
 BELOW WILL NOT BE ALTERED.
  
 PLEASE PROVIDE A COPY OF THE TEST REPORT.
  
 IF TILE EXISTING, REVISE PLAN TO INCLUDE THAT
 INFORMATION. SCOPE WILL BE CONFIRMED WITH THE INSPECTOR
 / PHOTOGRAPHS.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-03-04 Cont ID  
Sent By shill Date 2015-03-04 Time 17:53 Rev Time  
Received By shill Date 2015-03-02 Time   Sent To P
Notes
2015-03-04 17:55:55****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. PLANS TO BE ARCHITECTURAL QUALITY TO SCALE. ONE
 APPLICATION (15030034) IS FOR "MINOR DRYWALL REPAIR"
 BUT NOTHING ON PLAN SHOWING SCOPE / LOCATION. THERE
 SHOULD BE AN EXISTING AND PROPOSED PLAN. APPLICATION TO
 INCLUDE ALL WORK INCLUDED IN THE VIOLATION ISSUED. FBC
 107
  
 2. A PLUMBING PERMIT WAS SUBMITTED SIGNED BY A GC.
 PLEASE SEE FLORIDA STATUTE 489 FOR THE SCOPE OF WORK
 PERMITTED UNDER A GC LICENSE.
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2015-06-05 Cont ID  
Sent By mgonzale Date 2015-06-05 Time 14:35 Rev Time 1.00
Received By mgonzale Date 2015-06-17 Time 15:44 Sent To  
Notes
2015-06-05 14:46:28PROVISOS;
  
 WE WILL ADJUST STORM WATER ACCOUNT BASED ON GREEN
 (PERVIOUS AREA).
  
 FOR ANY TOPOGRAPHIC CHANGE THE ONWER MUST DEMONSTRATE
 MINIMUM DRAINAGE REQUIREMENTS: CITY ORDINANCE 3132-98,
 SECTION 32-18(A): "...IT SHALL BE UNLAWFUL FOR ANY
 PERSON TO DIRECTLY OR INDIRECTLY DEPOSIT, DISCHARGE,
 SPILL, OR DUMP INTO ANY OF THE PUBLIC WATERS OR
 MUNICIPAL SEPARATE STORM SEWER SYSTEM WITHIN THE CITY,
 ANY SUBSTANCE OTHER THAN THAT COMPOSED ENTIRELY OF
 STORM WATER." AND, SECTION 32-18(C): "NO PERSON MAY
 MAINTAIN, USE OR ESTABLISH ANY DIRECT OR INDIRECT
 CONNECTION TO THE STORM WATER SYSTEM THAT RESULTS IN
 ANY DISCHARGE IN VIOLATION OF THIS ORDINANCE. THIS
 PROHIBITION IS RETROACTIVE AND APPLIES TO CONNECTIONS
 MADE IN THE PAST, REGARDLESS OF WHETHER MADE UNDER A
 PERMIT, OR OTHER AUTHORIZATION, OR WHETHER PERMISSIBLE
 UNDER LAWS OR PRACTICES APPLICABLE OR PREVAILING AT THE
 TIME THE CONNECTION WAS MADE."
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-06-15 Cont ID  
Sent By lmarchan Date 2015-06-15 Time 10:38 Rev Time 0.00
Received By lmarchan Date 2015-04-29 Time 15:00 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-04-01 Cont ID  
Sent By shill Date 2015-04-01 Time 07:17 Rev Time 0.00
Received By shill Date 2015-03-17 Time   Sent To  
Notes
2015-03-18 13:44:21SENT TO S HILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-05 Cont ID  
Sent By tklarge Date 2015-03-05 Time 06:02 Rev Time  
Received By skennedy Date   Time   Sent To ENG
Notes
2015-03-03 06:33:29SENT TO <$5K BUILDING BOX.

Review Stop P PLUMBING
Rev No 2 Status N Date 2015-04-29 Cont ID  
Sent By skennedy Date 2015-04-29 Time 14:59 Rev Time 0.00
Received By skennedy Date   Time   Sent To  
Notes
2015-04-29 15:00:00N/A PERMIT TYPE CHANGED TO PAVING.

Review Stop P PLUMBING
Rev No 1 Status N Date 2015-06-03 Cont ID  
Sent By tklarge Date 2015-03-05 Time 06:02 Rev Time 0.00
Received By skennedy Date 2015-03-05 Time 06:02 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2015-06-02 Cont ID  
Sent By lmarchan Date 2015-06-15 Time 10:38 Rev Time 0.00
Received By sgraham Date 2015-06-02 Time 15:25 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-04-30 Cont ID  
Sent By sgraham Date 2015-04-30 Time 10:37 Rev Time 0.00
Received By sgraham Date 2015-04-30 Time 10:37 Sent To  
Notes
2015-04-30 10:40:564/30/15 ZONING FAILED
  
 1. PARKING LOT CAN NOT BE CHANGED TO LANDSCAPE AREA,
 YOU MUST REPLACE THE PARKING AREA WITH ASPHALT,
 CONCRETE OR PAVERS, THIS IS REQUIRED PARKING FOR THE
 APARTMENTS.
 2, SUBMIT A PLAN SHOWING THE PARKING LAYOUT,WITH THE
 DOUBLE STRIPPING AND THE LANDSCAPE AREAS