| Plan Review Stops For Permit 15020865 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-05-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-28 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-28 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2015-05-28 17:42:50 | PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY | | | COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR | | | INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL | | | CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110 | | | & FBC 117. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-05-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-21 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-20 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2015-05-20 18:44:09 | SEE MECHANICAL COMMENTS. | | | PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY | | | COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR | | | INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL | | | CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110 | | | & FBC 117. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-04-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-20 |
Time |
18:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-20 |
Time |
18:06 |
Sent To |
P |
|
| Notes |
| 2015-04-20 18:49:25 | PLAN REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE GARAGE STRUCTURE WILL REQUIRE A STRUCTURAL | | | ANALYSIS (907.2). SUBMIT TWO SETS OF A SIGNED AND | | | SEALED STRUCTURAL ANALYSIS ON THE EXISTING GARAGE FROM | | | A FLORIDA LICENSED ENGINEER. | | | GENERAL AFTER THE FACT PERMITS | | | PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY | | | COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR | | | INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL | | | CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110 | | | & FBC 117. | | | | | | | | | 2) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF | | | THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES, | | | STRUCTURAL MULLIONS, EXTERIOR DOOR TYPES AND SIMPSON | | | CONNECTORS. (SINGLE HUNG WINDOW AND MULLION PRODUCT | | | APPROVALS WERE SUBMITTED WITH ORIGINAL APPLICATION.) | | | NOTE: IF THE PRODUCT APPROVAL NUMBERS FOR THE SIMPSON | | | CONNECTORS ARE LISTED ON THE PLANS THEIR PRODUCT | | | APPROVALS DO NOT HAVE TO BE SUBMITTED. NOTE: THE | | | PRODUCT APPROVALS SUBMITTED FOR THE DOORS IS FOR A | | | SINGLE OUTSWING DOOR. SUBMIT THE ONES FOR DOUBLE | | | OUTSWING DOORS. SPECIFY THE WINDOWS THAT WILL BE | | | INSTALLED BY MARKING THE APPROPRIATE ONES ARE THEIR | | | DESIGN PRESSURES ON THE TABLES IN THE PRODUCT | | | APPROVALS. | | | | | | 3)SHOW COMPLIANCE WITH 2010 FBC ENERGY CONSERVATION | | | SECT. 101.4.3 & 103.2 BY SUBMITTING THE PROPER | | | CONSTRUCTION DOCUMENTS. SEE RESIDENTIAL BUILDING FORMS | | | 402 OR 405. | | | FBC ENERGY CONSERVATION - SECT. 103.2.3.2 CODE | | | COMPLIANCE CERTIFICATION. | | | THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER | | | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL | | | CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE | | | CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR | | | TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR | | | RENOVATION. | | | | | | 4) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-03-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-28 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-28 |
Time |
11:53 |
Sent To |
E |
|
| Notes |
| 2015-03-28 11:33:24 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE SCOPE OF WORK ON SHEET A-1 ITEM #2 STATES NEW | | | CBS BUILDING BETWEEN MAIN HOUSE. THE PALM BEACH COUNTY | | | PROPERTY APPRAISER AND THE SURVEY SHOW THE OTHER | | | BUILDING AS A DETACHED GARAGE. THE REVISED PLANS THAT | | | WERE SUBMITTED SHOW THE DETACHED GARAGE AS A GUEST | | | ROOM. I COULD NOT LOCATE ANY DOCUMENTATION THAT THE | | | GARAGE WAS LEGALLY CONVERTED TO HABITABLE SPACE WITH | | | THE REQUIRED PERMITS AND INSPECTIONS. PROVIDE THE | | | DOCUMENTATION OR THIS WILL BE A CHANGE OF OCCUPANCY AND | | | WILL BE REQUIRED TO COMPLY WITH CHAPTER 9 OF THE FBC | | | EXISTING BUILDING. THE STRUCTURE WILL REQUIRE A | | | STRUCTURAL ANALYSIS (907.2). ELECTRICAL, PLUMBING, | | | MECHANICAL AND ENERGY REQUIREMENTS WILL HAVE TO BE | | | ADDRESSED. PLEASE PROVIDE CLARIFICATION. FBC 107.2.1 | | | | | | 2) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF | | | THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES, | | | STRUCTURAL MULLIONS, EXTERIOR DOOR TYPES AND SIMPSON | | | CONNECTORS. (SINGLE HUNG WINDOW AND MULLION PRODUCT | | | APPROVALS WERE SUBMITTED WITH ORIGINAL APPLICATION.) | | | NOTE: IF THE PRODUCT APPROVAL NUMBERS FOR THE SIMPSON | | | CONNECTORS ARE LISTED ON THE PLANS THEIR PRODUCT | | | APPROVALS DO NOT HAVE TO BE SUBMITTED. | | | | | | 3) FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. THE VULT WIND SPEED | | | IS SPECIFIED AS 175 MPH IN ONE PLACE ONE SHEET A-1, | | | RATHER THAN 170MPH. THE WINDOW AND DOOR PRESSURES ON | | | A-2 ARE NOT CORRECT FOR EXPOSURE D. | | | | | | 4)SHOW COMPLIANCE WITH 2010 FBC ENERGY CONSERVATION | | | SECT. 101.4.3 & 103.2 BY SUBMITTING THE PROPER | | | CONSTRUCTION DOCUMENTS. SEE RESIDENTIAL BUILDING FORMS | | | 402 OR 405. | | | FBC ENERGY CONSERVATION - SECT. 103.2.3.2 CODE | | | COMPLIANCE CERTIFICATION. | | | THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER | | | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL | | | CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE | | | CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR | | | TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR | | | RENOVATION. | | | | | | 5) SHOW COMPLIANCE WITH R803.2.3.1 SHEATHING | | | FASTENINGS. WOOD STRUCTURAL PANEL SHEATHING SHALL BE | | | FASTENED TO ROOF FRAMING WITH 8D RING-SHANK NAILS AT 6 | | | INCHES ON CENTER AT EDGES AND 6 INCHES ON CENTER AT | | | INTERMEDIATE FRAMING. | | | WHERE ROOF FRAMING WITH A SPECIFIC GRAVITY, 0.42 < G < | | | 0.49 IS USED, SPACING OF RING-SHANK FASTENERS SHALL BE | | | 4 INCHES ON CENTER IN NAILING ZONE 3 IN ACCORDANCE WITH | | | FIGURE R803.2.3.1 WHERE VASD AS DETERMINED IN | | | ACCORDANCE WITH SECTION R301.2.1.3 IS 130 MPH OR | | | GREATER. | | | | | | 6) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED | | | GRADE. CONCRETE AND MASONRY FOUNDATION WALLS SHALL | | | EXTEND ABOVE THE FINISHED GRADE ADJACENT TO THE | | | FOUNDATION AT ALL POINTS A MINIMUM OF 4 INCHES (102 MM) | | | WHERE MASONRY VENEER IS USED AND A MINIMUM OF 6 INCHES | | | (152 MM) ELSEWHERE. | | | | | | 7) SHOW COMPLIANCE WITH R806 FOR ROOF VENTILATION. | | | | | | 8) THE WINDOW BUCK DETAILS ON SHEET A-2 ARE INCORRECT. | | | FBC- R612.10.2 ANCHORAGE DETAILS. UNLESS OTHERWISE | | | TESTED, BUCKS SHALL EXTEND BEYOND THE INTERIOR FACE OF | | | THE WINDOW OR DOOR FRAME SUCH THAT FULL SUPPORT OF THE | | | FRAME IS PROVIDED. | | | | | | 9) THE NOTE UNDER THE NEW EAST ELEVATION ON SHEET A-2 | | | IS INCORRECT. THE 2010 FBC AND ASCE 7-10 ARE THE ONES | | | THAT APPLY TO THIS PROJECT. THERE IS NO VULT LOW WIND | | | SPEED. THE VASD OR V NOMINAL WIND SPEED IS 132 MPH FOR | | | THIS PROJECT. | | | | | | 10) PROVIDE A STRUCTURAL DETAIL SHOWING HOW THE NEW | | | BLOCK WALL AND U BEAMS WILL BE TIED INTO THE EXISTING | | | STRUCTURES. FBC 301.1 | | | | | | 11) ON SHEET A-3, THE NOTE UNDER THE LINTEL DESIGN | | | REFERENCES THE 2007 FBC AND NOT THE 2010 FBC. | | | | | | 12) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-04-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-21 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-04-16 |
Time |
16:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-04-09 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-04-09 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-04-09 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2015-04-09 16:11:12 | 1) RISER IS CONFLICTING WITH PREVIOUS PERMIT #14100615 | | | FOR KITCHEN AND BATH RENOVATION. PREVIOUS PERMIT | | | INDICATE MAIN HOUSE PANEL IN THE HALLWAY OF MAIN | | | RESIDENCE. REVISE RISER TO INDICATE ALL PANELS AND TO | | | REFLECT ACTUAL FIELD CONDITIONS. | | | 2) LOAD CALCULATION IS CONFLICTING WITH RISER DIAGRAM. | | | LOAD CALCULATION INDICATES A 159AMP TOTAL CONNECTED | | | LOAD. THE RISER DIAGRAM INDICATES A 150AMP ELECTRICAL | | | SERVICE MAIN. REVISE RISER TO INDICATE SERVICE MAIN | | | SIZED TO SUPPORT THE TOTAL CONNECTED LOAD. | | | 3) INDICATE SWITCHED LIGHTS AT THE DOORS OFF OF THE | | | FAMILY ROOM. NEC 210.70(2)(B) | | | 4) INDICATE SMOKE DETECTORS INDIDE AND OUTSIDE OF GUEST | | | ROOM AMD THROUGHOUT MAIN RESIDENCE WHERE REQUIRED. | | | FBC-RESIDENTIAL 314 AND 315. | | | 5) CLARIFY AND REVISE AS NEEDED. PANEL SCHEDULE | | | INDICATES 15AMP CIRCUITS WHERE 20AMP MAY BE REQUIRED. | | | FOR INSTANCE KITCHEN, DINING ROOM AND EXISTING GFI. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-03-30 |
|
|
Cont ID |
|
| Sent By |
mcdouga |
Date |
2015-03-30 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-03-30 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2015-03-30 13:30:16 | SEE BUILDING COMMENTS. | | | NOTHING ON FILE FOR A LEGAL GARAGE CONVERSION TO GUEST | | | ROOM. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2015-05-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-28 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-28 |
Time |
18:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-05-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-21 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-14 |
Time |
18:33 |
Sent To |
|
|
| Notes |
| 2015-05-14 18:33:28 | TO RM DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-05-21 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-04-21 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-08 |
Time |
16:49 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-03-30 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-03-30 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-02-26 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2015-03-09 08:16:18 | REVISION RE-SUBMITTAL (SURVEYS) SUBMITTED WITHOUT FIRST | | | REVIEW CYCLE WAS COMPLETED. SENT TO R4 BIN FOR REVIEW. | | | JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-03-12 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-03-04 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-02-26 |
Time |
07:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2015-05-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-20 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-20 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2015-05-20 18:39:48 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-04-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-04-16 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-04-16 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2015-04-16 14:30:15 | SEE PREVIOUS COMMENTS. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-03-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-27 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-27 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2015-03-27 17:33:16 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2015-05-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-28 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-28 |
Time |
17:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2015-05-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-21 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-20 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2015-05-21 08:32:56 | PLAN | | | REVIEW COMMENTS | | | | | | 3RD REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SPECIFY THE SIZE OF THE RETURN AIR "JUMPER" (DUCT | | | AND GRILL) BETWEEN THE HALL AND THE GUEST ROOM. SPECIFY | | | WHAT TYPE OF "JUMPER" (A TRANSFER DUCT OR A TRANSFER | | | GRILL) WILL BE USED. FBC-R M1602.4 | | | | | | 2) ONLY THE SUMMARY PAGE FOR THE EQUIPMENT SIZING | | | CALCULATIONS WAS SUBMITTED. SUBMIT THE COMPLETE | | | CALCULATIONS. FBC 107.2.1 & ENERGY CODE SECTION 403.6.1 | | | | | | 3) SPECIFY ON THE PLAN THAT THERE IS A LOUVERED DOOR ON | | | THE AIR HANDLER CLOSET FOR RETURN AIR. FBC-R M1602.4 | | | | | | 4) THE SQUARE FOOTAGE OF THE GUEST HOUSE CONVERSION IS | | | 500 SQFT ON THE MECHANICAL PLANS AND 529 SQFT ON THE | | | ARCHITECTURAL PLANS. FBC 107.2.1 | | | | | | 5) FORM 402 IS NOT CORRECT AND INCOMPLETE. BASED ON THE | | | INFORMATION ON THE FORM, THE PROJECT WILL NOT COMPLY | | | USING THIS METHOD. THE PERFORMANCE METHOD, SECTION 405 | | | OF THE ENERGY CODE CAN BE USED TO SHOW COMPLIANCE. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2015-04-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-20 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-20 |
Time |
17:56 |
Sent To |
|
|
| Notes |
| 2015-04-20 18:05:56 | PLAN REVIEW COMMENTS | | | | | | 3RD REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC - 107.3.5.3 PROVIDE A MECHANICAL PLAN TO SHOW | | | SUPPLY DUCTS PER FBC-R M16 & BATH EXHAUST PER FBC-R | | | M15. | | | | | | 2) FBC-R - M1401.3 SIZING. HEATING AND COOLING | | | EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS | | | CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER | | | APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. | | | PROVIDE EQUIPMENT SIZING CALCULATIONS. | | | | | | 3) FBC 107.2.1 PROVIDE THE MODEL NUMBERS AND | | | SPECIFICATIONS OF THE HEATING AND COOLING EQUIPMENT IN | | | AN EQUIPMENT SCHEDULE ON THE MECHANICAL PLAN THAT | | | CORRESPONDS WITH THE EQUIPMENT SIZING CALCULATIONS. | | | | | | 4) SHOW COMPLIANCE WITH 2010 FBC ENERGY CONSERVATION | | | SECT. 101.4.3 & 103.2 BY SUBMITTING THE PROPER | | | CONSTRUCTION DOCUMENTS FOR THE ADDITION AND CONVERTED | | | GARAGE. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-04-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-16 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-04-16 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2015-04-16 14:33:21 | 2ND REVIEW, FBC 2010. SEE PREVIOUS COMMENTS. YOU DID | | | NOT PROVIDE RESPOND TO THE COMMENT BY ROBERT MCDOUGAL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-03-28 |
|
|
Cont ID |
|
| Sent By |
mcdouga |
Date |
2015-03-28 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-28 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2015-03-28 11:58:33 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC - 107.3.5.3 PROVIDE A MECHANICAL PLAN TO SHOW | | | SUPPLY DUCTS PER FBC-R M16 & BATH EXHAUST PER FBC-R | | | M15. | | | | | | 2) FBC-R - M1401.3 SIZING. HEATING AND COOLING | | | EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS | | | CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER | | | APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. | | | PROVIDE EQUIPMENT SIZING CALCULATIONS. | | | | | | 3) FBC 107.2.1 PROVIDE THE MODEL NUMBERS AND | | | SPECIFICATIONS OF THE HEATING AND COOLING EQUIPMENT IN | | | AN EQUIPMENT SCHEDULE ON THE MECHANICAL PLAN THAT | | | CORRESPONDS WITH THE EQUIPMENT SIZING CALCULATIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-04-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-04-21 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-04-21 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2015-04-21 12:01:42 | A CODE COMPLIANT SANITARY RISER DIAGRAM SHALL BE | | | SUBMITTED PRIOR TO INSPECTION. 2010 FBC SEC. 107.2.1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2015-04-16 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2015-04-16 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-04-16 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-03-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-03-16 |
Time |
05:57 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-03-16 |
Time |
05:42 |
Sent To |
|
|
| Notes |
| 2015-03-16 05:57:25 | 1) THE NEW LAUNDRY ALSO SHOWS A WATER CLOSET AND A | | | LAVATORY BUT THE PLAN DOES NOT SHOW IF THEY ARE NEW OR | | | EXISTING. CLARIFY ON BOTH SETS OF PLANS. IF NEW, ADD | | | THE FIXTURES ON THE PLUMBING RISER. WPB AMEND. TO 2010 | | | FBC SEC. 107.2.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-03-12 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-03-12 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-03-12 |
Time |
15:34 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-03-04 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-03-04 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-03-04 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2015-03-04 14:48:08 | 3/4/15 ZONING FAILED. | | | | | | 1. PROVIDE TWO COPIES OF AN UP TO DATE SURVEY,SHOWING | | | THE LOCATION OF THE ADDITION, IF THE REAR SETBACK IS | | | NOT 10' FT OR 10% OF THE DEPTH OF THE LOT YOU WILL NOT | | | BE ALLOWED TO CONNECT THE PRIMARY HOUSE TO THE | | | GARAGE. YOU HAVE WHAT WE CALL A NON CONFORMING USE, WE | | | CAN NOT ALLOW TO IMPACT A NON CONFORMITY. |
|
|