Plan Review Details - Permit 15020865
Plan Review Stops For Permit 15020865
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2015-05-28 Cont ID  
Sent By rmcdouga Date 2015-05-28 Time 17:42 Rev Time 0.00
Received By rmcdouga Date 2015-05-28 Time 17:34 Sent To  
Notes
2015-05-28 17:42:50PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY
 COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR
 INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL
 CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110
 & FBC 117.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-05-21 Cont ID  
Sent By rmcdouga Date 2015-05-21 Time 09:40 Rev Time 0.00
Received By rmcdouga Date 2015-05-20 Time 18:38 Sent To  
Notes
2015-05-20 18:44:09SEE MECHANICAL COMMENTS.
 PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY
 COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR
 INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL
 CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110
 & FBC 117.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-04-20 Cont ID  
Sent By rmcdouga Date 2015-04-20 Time 18:49 Rev Time 0.00
Received By rmcdouga Date 2015-04-20 Time 18:06 Sent To P
Notes
2015-04-20 18:49:25PLAN REVIEW COMMENTS
  
 2ND REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE GARAGE STRUCTURE WILL REQUIRE A STRUCTURAL
 ANALYSIS (907.2). SUBMIT TWO SETS OF A SIGNED AND
 SEALED STRUCTURAL ANALYSIS ON THE EXISTING GARAGE FROM
 A FLORIDA LICENSED ENGINEER.
 GENERAL AFTER THE FACT PERMITS
 PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY
 COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR
 INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL
 CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110
 & FBC 117.
  
  
 2) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3
 THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT
 APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION
 INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF
 THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES,
 STRUCTURAL MULLIONS, EXTERIOR DOOR TYPES AND SIMPSON
 CONNECTORS. (SINGLE HUNG WINDOW AND MULLION PRODUCT
 APPROVALS WERE SUBMITTED WITH ORIGINAL APPLICATION.)
 NOTE: IF THE PRODUCT APPROVAL NUMBERS FOR THE SIMPSON
 CONNECTORS ARE LISTED ON THE PLANS THEIR PRODUCT
 APPROVALS DO NOT HAVE TO BE SUBMITTED. NOTE: THE
 PRODUCT APPROVALS SUBMITTED FOR THE DOORS IS FOR A
 SINGLE OUTSWING DOOR. SUBMIT THE ONES FOR DOUBLE
 OUTSWING DOORS. SPECIFY THE WINDOWS THAT WILL BE
 INSTALLED BY MARKING THE APPROPRIATE ONES ARE THEIR
 DESIGN PRESSURES ON THE TABLES IN THE PRODUCT
 APPROVALS.
  
 3)SHOW COMPLIANCE WITH 2010 FBC ENERGY CONSERVATION
 SECT. 101.4.3 & 103.2 BY SUBMITTING THE PROPER
 CONSTRUCTION DOCUMENTS. SEE RESIDENTIAL BUILDING FORMS
 402 OR 405.
 FBC ENERGY CONSERVATION - SECT. 103.2.3.2 CODE
 COMPLIANCE CERTIFICATION.
 THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE
 CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR
 TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION.
  
 4) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE
 CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER
 INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN
 ADDRESSED.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-03-28 Cont ID  
Sent By rmcdouga Date 2015-03-28 Time 11:53 Rev Time 0.00
Received By rmcdouga Date 2015-03-28 Time 11:53 Sent To E
Notes
2015-03-28 11:33:24PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE SCOPE OF WORK ON SHEET A-1 ITEM #2 STATES NEW
 CBS BUILDING BETWEEN MAIN HOUSE. THE PALM BEACH COUNTY
 PROPERTY APPRAISER AND THE SURVEY SHOW THE OTHER
 BUILDING AS A DETACHED GARAGE. THE REVISED PLANS THAT
 WERE SUBMITTED SHOW THE DETACHED GARAGE AS A GUEST
 ROOM. I COULD NOT LOCATE ANY DOCUMENTATION THAT THE
 GARAGE WAS LEGALLY CONVERTED TO HABITABLE SPACE WITH
 THE REQUIRED PERMITS AND INSPECTIONS. PROVIDE THE
 DOCUMENTATION OR THIS WILL BE A CHANGE OF OCCUPANCY AND
 WILL BE REQUIRED TO COMPLY WITH CHAPTER 9 OF THE FBC
 EXISTING BUILDING. THE STRUCTURE WILL REQUIRE A
 STRUCTURAL ANALYSIS (907.2). ELECTRICAL, PLUMBING,
 MECHANICAL AND ENERGY REQUIREMENTS WILL HAVE TO BE
 ADDRESSED. PLEASE PROVIDE CLARIFICATION. FBC 107.2.1
  
 2) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3
 THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT
 APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION
 INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF
 THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES,
 STRUCTURAL MULLIONS, EXTERIOR DOOR TYPES AND SIMPSON
 CONNECTORS. (SINGLE HUNG WINDOW AND MULLION PRODUCT
 APPROVALS WERE SUBMITTED WITH ORIGINAL APPLICATION.)
 NOTE: IF THE PRODUCT APPROVAL NUMBERS FOR THE SIMPSON
 CONNECTORS ARE LISTED ON THE PLANS THEIR PRODUCT
 APPROVALS DO NOT HAVE TO BE SUBMITTED.
  
 3) FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2. THE VULT WIND SPEED
 IS SPECIFIED AS 175 MPH IN ONE PLACE ONE SHEET A-1,
 RATHER THAN 170MPH. THE WINDOW AND DOOR PRESSURES ON
 A-2 ARE NOT CORRECT FOR EXPOSURE D.
  
 4)SHOW COMPLIANCE WITH 2010 FBC ENERGY CONSERVATION
 SECT. 101.4.3 & 103.2 BY SUBMITTING THE PROPER
 CONSTRUCTION DOCUMENTS. SEE RESIDENTIAL BUILDING FORMS
 402 OR 405.
 FBC ENERGY CONSERVATION - SECT. 103.2.3.2 CODE
 COMPLIANCE CERTIFICATION.
 THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE
 CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR
 TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION.
  
 5) SHOW COMPLIANCE WITH R803.2.3.1 SHEATHING
 FASTENINGS. WOOD STRUCTURAL PANEL SHEATHING SHALL BE
 FASTENED TO ROOF FRAMING WITH 8D RING-SHANK NAILS AT 6
 INCHES ON CENTER AT EDGES AND 6 INCHES ON CENTER AT
 INTERMEDIATE FRAMING.
 WHERE ROOF FRAMING WITH A SPECIFIC GRAVITY, 0.42 < G <
 0.49 IS USED, SPACING OF RING-SHANK FASTENERS SHALL BE
 4 INCHES ON CENTER IN NAILING ZONE 3 IN ACCORDANCE WITH
 FIGURE R803.2.3.1 WHERE VASD AS DETERMINED IN
 ACCORDANCE WITH SECTION R301.2.1.3 IS 130 MPH OR
 GREATER.
  
 6) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED
 GRADE. CONCRETE AND MASONRY FOUNDATION WALLS SHALL
 EXTEND ABOVE THE FINISHED GRADE ADJACENT TO THE
 FOUNDATION AT ALL POINTS A MINIMUM OF 4 INCHES (102 MM)
 WHERE MASONRY VENEER IS USED AND A MINIMUM OF 6 INCHES
 (152 MM) ELSEWHERE.
  
 7) SHOW COMPLIANCE WITH R806 FOR ROOF VENTILATION.
  
 8) THE WINDOW BUCK DETAILS ON SHEET A-2 ARE INCORRECT.
 FBC- R612.10.2 ANCHORAGE DETAILS. UNLESS OTHERWISE
 TESTED, BUCKS SHALL EXTEND BEYOND THE INTERIOR FACE OF
 THE WINDOW OR DOOR FRAME SUCH THAT FULL SUPPORT OF THE
 FRAME IS PROVIDED.
  
 9) THE NOTE UNDER THE NEW EAST ELEVATION ON SHEET A-2
 IS INCORRECT. THE 2010 FBC AND ASCE 7-10 ARE THE ONES
 THAT APPLY TO THIS PROJECT. THERE IS NO VULT LOW WIND
 SPEED. THE VASD OR V NOMINAL WIND SPEED IS 132 MPH FOR
 THIS PROJECT.
  
 10) PROVIDE A STRUCTURAL DETAIL SHOWING HOW THE NEW
 BLOCK WALL AND U BEAMS WILL BE TIED INTO THE EXISTING
 STRUCTURES. FBC 301.1
  
 11) ON SHEET A-3, THE NOTE UNDER THE LINTEL DESIGN
 REFERENCES THE 2007 FBC AND NOT THE 2010 FBC.
  
 12) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE
 CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER
 INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN
 ADDRESSED.
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-04-16 Cont ID  
Sent By rmcdouga Date 2015-05-21 Time 09:41 Rev Time 0.00
Received By dhayes Date 2015-04-16 Time 16:08 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-04-09 Cont ID  
Sent By dhayes Date 2015-04-09 Time 16:07 Rev Time 0.00
Received By dhayes Date 2015-04-09 Time 16:07 Sent To  
Notes
2015-04-09 16:11:121) RISER IS CONFLICTING WITH PREVIOUS PERMIT #14100615
 FOR KITCHEN AND BATH RENOVATION. PREVIOUS PERMIT
 INDICATE MAIN HOUSE PANEL IN THE HALLWAY OF MAIN
 RESIDENCE. REVISE RISER TO INDICATE ALL PANELS AND TO
 REFLECT ACTUAL FIELD CONDITIONS.
 2) LOAD CALCULATION IS CONFLICTING WITH RISER DIAGRAM.
 LOAD CALCULATION INDICATES A 159AMP TOTAL CONNECTED
 LOAD. THE RISER DIAGRAM INDICATES A 150AMP ELECTRICAL
 SERVICE MAIN. REVISE RISER TO INDICATE SERVICE MAIN
 SIZED TO SUPPORT THE TOTAL CONNECTED LOAD.
 3) INDICATE SWITCHED LIGHTS AT THE DOORS OFF OF THE
 FAMILY ROOM. NEC 210.70(2)(B)
 4) INDICATE SMOKE DETECTORS INDIDE AND OUTSIDE OF GUEST
 ROOM AMD THROUGHOUT MAIN RESIDENCE WHERE REQUIRED.
 FBC-RESIDENTIAL 314 AND 315.
 5) CLARIFY AND REVISE AS NEEDED. PANEL SCHEDULE
 INDICATES 15AMP CIRCUITS WHERE 20AMP MAY BE REQUIRED.
 FOR INSTANCE KITCHEN, DINING ROOM AND EXISTING GFI.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-03-30 Cont ID  
Sent By mcdouga Date 2015-03-30 Time 12:56 Rev Time 0.00
Received By dhayes Date 2015-03-30 Time 13:30 Sent To  
Notes
2015-03-30 13:30:16SEE BUILDING COMMENTS.
 NOTHING ON FILE FOR A LEGAL GARAGE CONVERSION TO GUEST
 ROOM.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2015-05-28 Cont ID  
Sent By rmcdouga Date 2015-05-28 Time 18:15 Rev Time 0.00
Received By rmcdouga Date 2015-05-28 Time 18:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-05-21 Cont ID  
Sent By rmcdouga Date 2015-05-21 Time 09:40 Rev Time 0.00
Received By rmcdouga Date 2015-05-14 Time 18:33 Sent To  
Notes
2015-05-14 18:33:28TO RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-05-21 Cont ID  
Sent By dhayes Date 2015-04-21 Time 12:02 Rev Time 0.00
Received By rmcdouga Date 2015-04-08 Time 16:49 Sent To E
Notes
2015-04-09 16:47:23R10

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-03-30 Cont ID  
Sent By dhayes Date 2015-03-30 Time 13:30 Rev Time 0.00
Received By dhayes Date 2015-02-26 Time 17:33 Sent To  
Notes
2015-03-09 08:16:18REVISION RE-SUBMITTAL (SURVEYS) SUBMITTED WITHOUT FIRST
 REVIEW CYCLE WAS COMPLETED. SENT TO R4 BIN FOR REVIEW.
 JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-12 Cont ID  
Sent By skennedy Date 2015-03-04 Time 17:35 Rev Time 0.00
Received By skennedy Date 2015-02-26 Time 07:13 Sent To  
Notes
2015-02-27 07:14:31R04
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2015-05-20 Cont ID  
Sent By rmcdouga Date 2015-05-20 Time 18:38 Rev Time 0.00
Received By rmcdouga Date 2015-05-20 Time 18:38 Sent To  
Notes
2015-05-20 18:39:48BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-04-16 Cont ID  
Sent By skennedy Date 2015-04-16 Time 14:29 Rev Time 0.00
Received By skennedy Date 2015-04-16 Time 14:29 Sent To  
Notes
2015-04-16 14:30:15SEE PREVIOUS COMMENTS.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-03-27 Cont ID  
Sent By rmcdouga Date 2015-03-27 Time 17:33 Rev Time 0.00
Received By rmcdouga Date 2015-03-27 Time 17:33 Sent To  
Notes
2015-03-27 17:33:16BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2015-05-28 Cont ID  
Sent By rmcdouga Date 2015-05-28 Time 17:51 Rev Time 0.00
Received By rmcdouga Date 2015-05-28 Time 17:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2015-05-21 Cont ID  
Sent By rmcdouga Date 2015-05-21 Time 08:33 Rev Time 0.00
Received By rmcdouga Date 2015-05-20 Time 18:38 Sent To  
Notes
2015-05-21 08:32:56PLAN
 REVIEW COMMENTS
  
 3RD REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SPECIFY THE SIZE OF THE RETURN AIR "JUMPER" (DUCT
 AND GRILL) BETWEEN THE HALL AND THE GUEST ROOM. SPECIFY
 WHAT TYPE OF "JUMPER" (A TRANSFER DUCT OR A TRANSFER
 GRILL) WILL BE USED. FBC-R M1602.4
  
 2) ONLY THE SUMMARY PAGE FOR THE EQUIPMENT SIZING
 CALCULATIONS WAS SUBMITTED. SUBMIT THE COMPLETE
 CALCULATIONS. FBC 107.2.1 & ENERGY CODE SECTION 403.6.1
  
 3) SPECIFY ON THE PLAN THAT THERE IS A LOUVERED DOOR ON
 THE AIR HANDLER CLOSET FOR RETURN AIR. FBC-R M1602.4
  
 4) THE SQUARE FOOTAGE OF THE GUEST HOUSE CONVERSION IS
 500 SQFT ON THE MECHANICAL PLANS AND 529 SQFT ON THE
 ARCHITECTURAL PLANS. FBC 107.2.1
  
 5) FORM 402 IS NOT CORRECT AND INCOMPLETE. BASED ON THE
 INFORMATION ON THE FORM, THE PROJECT WILL NOT COMPLY
 USING THIS METHOD. THE PERFORMANCE METHOD, SECTION 405
 OF THE ENERGY CODE CAN BE USED TO SHOW COMPLIANCE.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2015-04-20 Cont ID  
Sent By rmcdouga Date 2015-04-20 Time 17:56 Rev Time 0.00
Received By rmcdouga Date 2015-04-20 Time 17:56 Sent To  
Notes
2015-04-20 18:05:56PLAN REVIEW COMMENTS
  
 3RD REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC - 107.3.5.3 PROVIDE A MECHANICAL PLAN TO SHOW
 SUPPLY DUCTS PER FBC-R M16 & BATH EXHAUST PER FBC-R
 M15.
  
 2) FBC-R - M1401.3 SIZING. HEATING AND COOLING
 EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS
 CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER
 APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES.
 PROVIDE EQUIPMENT SIZING CALCULATIONS.
  
 3) FBC 107.2.1 PROVIDE THE MODEL NUMBERS AND
 SPECIFICATIONS OF THE HEATING AND COOLING EQUIPMENT IN
 AN EQUIPMENT SCHEDULE ON THE MECHANICAL PLAN THAT
 CORRESPONDS WITH THE EQUIPMENT SIZING CALCULATIONS.
  
 4) SHOW COMPLIANCE WITH 2010 FBC ENERGY CONSERVATION
 SECT. 101.4.3 & 103.2 BY SUBMITTING THE PROPER
 CONSTRUCTION DOCUMENTS FOR THE ADDITION AND CONVERTED
 GARAGE.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-04-16 Cont ID  
Sent By rmcdouga Date 2015-04-16 Time 14:30 Rev Time 0.00
Received By skennedy Date 2015-04-16 Time 14:30 Sent To  
Notes
2015-04-16 14:33:212ND REVIEW, FBC 2010. SEE PREVIOUS COMMENTS. YOU DID
 NOT PROVIDE RESPOND TO THE COMMENT BY ROBERT MCDOUGAL.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-03-28 Cont ID  
Sent By mcdouga Date 2015-03-28 Time 11:58 Rev Time 0.00
Received By rmcdouga Date 2015-03-28 Time 11:55 Sent To  
Notes
2015-03-28 11:58:33PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC - 107.3.5.3 PROVIDE A MECHANICAL PLAN TO SHOW
 SUPPLY DUCTS PER FBC-R M16 & BATH EXHAUST PER FBC-R
 M15.
  
 2) FBC-R - M1401.3 SIZING. HEATING AND COOLING
 EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS
 CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER
 APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES.
 PROVIDE EQUIPMENT SIZING CALCULATIONS.
  
 3) FBC 107.2.1 PROVIDE THE MODEL NUMBERS AND
 SPECIFICATIONS OF THE HEATING AND COOLING EQUIPMENT IN
 AN EQUIPMENT SCHEDULE ON THE MECHANICAL PLAN THAT
 CORRESPONDS WITH THE EQUIPMENT SIZING CALCULATIONS.

Review Stop P PLUMBING
Rev No 3 Status P Date 2015-04-21 Cont ID  
Sent By tklarge Date 2015-04-21 Time 11:56 Rev Time 0.00
Received By tklarge Date 2015-04-21 Time 11:56 Sent To  
Notes
2015-04-21 12:01:42A CODE COMPLIANT SANITARY RISER DIAGRAM SHALL BE
 SUBMITTED PRIOR TO INSPECTION. 2010 FBC SEC. 107.2.1.

Review Stop P PLUMBING
Rev No 2 Status N Date 2015-04-16 Cont ID  
Sent By tlarge Date 2015-04-16 Time 14:26 Rev Time 0.00
Received By skennedy Date 2015-04-16 Time 14:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-03-16 Cont ID  
Sent By tklarge Date 2015-03-16 Time 05:57 Rev Time 0.00
Received By tklarge Date 2015-03-16 Time 05:42 Sent To  
Notes
2015-03-16 05:57:251) THE NEW LAUNDRY ALSO SHOWS A WATER CLOSET AND A
 LAVATORY BUT THE PLAN DOES NOT SHOW IF THEY ARE NEW OR
 EXISTING. CLARIFY ON BOTH SETS OF PLANS. IF NEW, ADD
 THE FIXTURES ON THE PLUMBING RISER. WPB AMEND. TO 2010
 FBC SEC. 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2015-03-12 Cont ID  
Sent By sgraham Date 2015-03-12 Time 15:34 Rev Time 0.00
Received By sgraham Date 2015-03-12 Time 15:34 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-03-04 Cont ID  
Sent By sgraham Date 2015-03-04 Time 14:44 Rev Time 0.00
Received By sgraham Date 2015-03-04 Time 14:44 Sent To  
Notes
2015-03-04 14:48:083/4/15 ZONING FAILED.
  
 1. PROVIDE TWO COPIES OF AN UP TO DATE SURVEY,SHOWING
 THE LOCATION OF THE ADDITION, IF THE REAR SETBACK IS
 NOT 10' FT OR 10% OF THE DEPTH OF THE LOT YOU WILL NOT
 BE ALLOWED TO CONNECT THE PRIMARY HOUSE TO THE
 GARAGE. YOU HAVE WHAT WE CALL A NON CONFORMING USE, WE
 CAN NOT ALLOW TO IMPACT A NON CONFORMITY.