Plan Review Details - Permit 15020486
Plan Review Stops For Permit 15020486
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-03-16 Cont ID  
Sent By jwitmer Date 2015-03-16 Time 16:18 Rev Time 0.00
Received By jwitmer Date 2015-03-16 Time 16:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2015-02-23 Time   Rev Time  
Received By   Date 2015-02-23 Time   Sent To  
Notes
2015-02-24 07:38:47PROVISO: SHELL PERMIT: 14120661 MUST BE ISSUED 1ST.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-03-10 Cont ID  
Sent By dhayes Date 2015-03-10 Time 10:29 Rev Time 0.00
Received By dhayes Date 2015-03-10 Time 10:29 Sent To  
Notes
2015-03-10 10:40:14ELECTRICAL PERMIT REQUIRED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-03-17 Cont ID  
Sent By pleduc Date 2015-03-17 Time   Rev Time 0.00
Received By pleduc Date 2015-03-17 Time 15:51 Sent To PC
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-03-02 Cont ID  
Sent By pleduc Date 2015-03-02 Time   Rev Time 0.00
Received By pleduc Date 2015-03-02 Time 15:51 Sent To  
Notes
2015-03-02 17:20:34THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 SHEET G - 010 INCORRECT REFERENCES TO THE CURRENT
 EDITION OF THE FIRE CODE. PLEASE CORRECT AND REFERENCE
 THAT THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS
 OF THE 5TH EDITION OF FLORIDA FIRE PREVENTION CODE
 INCLUDING THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND
 ALL OTHER APPLICABLE CODES OR STANDARDS.
  
 IT IS UNCLEAR ON THE SUBMITTED PLAN WHAT IS EXISTING.
 PLEASE CLEARLY INDICATE WHAT IS EXISTING AND WHAT IS
 PROPOSED. IF A NEW WALL IS BEING INSTALLED IT SHALL BE
 FIRE RATED ACCORDING TO THE SEPARATION REQUIREMENTS OF
 STORAGE AND BUSINESS/MERCANTILE.
  
 THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE
 FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND
 COMPLIANCE.
  
 PLEASE MAKE REFERENCE TO THE FOLLOWING ON THE SUBMITTED
 PLAN:
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-03-17 Cont ID  
Sent By pleduc Date 2015-03-17 Time   Rev Time 0.00
Received By pleduc Date 2015-03-16 Time   Sent To  
Notes
2015-03-16 16:18:32SENT TO FIRE BOX. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-10 Cont ID  
Sent By dhayes Date 2015-03-10 Time 10:29 Rev Time  
Received By dhayes Date 2015-02-13 Time   Sent To  
Notes
2015-02-18 08:32:17B10

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2015-02-23 Time   Rev Time  
Received By   Date 2015-02-23 Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2015-02-28 Cont ID  
Sent By tklarge Date 2015-02-28 Time 11:11 Rev Time 0.00
Received By tklarge Date 2015-02-28 Time 11:05 Sent To  
Notes
***NONE***