| Plan Review Stops For Permit 15020227 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-05-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-08 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-08 |
Time |
07:15 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-04-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-17 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-16 |
Time |
19:09 |
Sent To |
|
|
| Notes |
| 2015-04-17 14:29:17 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) ONE SET OF THE PLANS IS MISSING SETS A-20, A-21 AND | | | A-22. TWO COMPLETE SETS OF PLANS ARE REQUIRED. FBC | | | 107.1 | | | | | | 2) A PRODUCT APPROVAL NOA NO. 12-0612.15 WAS SUBMITTED | | | FOR EXTERIOR DOORS. IT IS FOR FIBERGLASS DOORS WITH | | | SIDELITES WITH A OXX OR XXO CONFIGURATION AND A MAXIMUM | | | FRAME WITDTH OF 108-1/2". THERE ARE NOT ANY DOORS LIKE | | | THIS SPECIFIED ON THE PLANS. THE DOOR SCHEDULE | | | SPECIFIES METAL DOORS. THERE ARE SINGLE AND DOUBLE | | | FRENCH DOORS AND DOUBLE FRENCH DOORS WITH SIDELITES ON | | | BOTH SIDES ON THE PLANS. | | | | | | 3) SUBMIT TWO SETS OF PRODUCT APPROVALS WITH | | | INSTALLATION INSTRUCTIONS AND DESIGN WIND LOAD | | | PRESSURES FOR THE CLAY BARREL ROOF TILE AS REQUIRED BY | | | DCA RULE 9N-3. SPECIFY WHICH ONE OF THE ATTACHMENT | | | METHODS WITH ADEQUATE UPLIFT RESISTANCE THAT ARE LISTED | | | IN THE PRODUCT APPROVAL WILL BE USED. IF A ROOF TILE | | | ADHESIVE IS TO BE USED, THEN SUBMIT TWO COPIES OF IT'S | | | PRODUCT APPROVALS. FBC 107.2.1 AND FBC-R301.1 | | | | | | 4) ONE SET OF PRODUCT APPROVALS WERE SUBMITTED FOR | | | SEALOFLEX ROOF SYSTEMS FOR CONCRETE (NOA NO. | | | 12-0418.04), ONE FOR SEALOFLEX WATERPROOFING SYSTEM FOR | | | CONCRETE (NOA NO.10-0608.04) AND ONE FOR SEALOFLEX | | | WATERPROOFING SYSTEM FOR LIGHTWEIGHT CONCRETE (NOA | | | NO.10-0608.03). SPECIFY WHERE EACH WILL BE INSTALLED | | | AND INDICATE THE SPECIFIC ASSEMBLY AND ITS DESIGN | | | PRESSURE. FBC 107.2.1 AND FBC-R301.1 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-17 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-16 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2015-03-17 11:04:33 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) PROVIDE STRUCTURAL DETAILS FOR THE PROPOSED PERGOLA | | | AT THE POOL HOUSE. FBC-R 301.1 | | | | | | 2) PROVIDE STRUCTURAL DRAWINGS FOR THE ARCHED BEAMS | | | THAT SHOW THE STEEL PLACEMENT. FBC 107.2.1 | | | | | | 3) IN THE FLAT BEAM SCHEDULE ON SHEET S-21, THERE ARE | | | TWO FB-1 MARKS LISTED. IT APPEARS THAT THE SECOND ONE | | | SHOULD BE FB-2. FBC 107.2.1 | | | | | | 4) PROVIDE SCUPPER SIZING CALCULATIONS AND SPECIFY THE | | | SIZES OF THE ROOF SCUPPERS AND OVERFLOW SCUPPERS FOR | | | THE NEW POOL HOUSE LOW SLOPE ROOF ON THE PLANS. FBC-R | | | 903.4 | | | | | | 5) R318.6 PROTECTION AGAINST DECAY AND TERMITES. | | | CONDENSATE LINES, IRRIGATION/SPRINKLER SYSTEM RISERS | | | FOR SPRAY HEADS, AND ROOF DOWNSPOUTS SHALL DISCHARGE AT | | | LEAST 1 FOOT (305 MM) AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS OR | | | SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON | | | ALL BUILDINGS WITH EAVES OF LESS THAN 6 INCHES (152 MM) | | | HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON | | | A ROOF ABOVE ANOTHER ROOF. | | | | | | 6) SHOW COMPLIANCE WITH FBC 807.1 FOR ATTIC ACCESS. | | | BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTION | | | SHALL HAVE AN ATTIC ACCESS OPENING TO ATTIC AREAS THAT | | | EXCEED 30 SQUARE FEET (2.8 M2) AND HAVE A VERTICAL | | | HEIGHT OF 30 INCHES (762 MM) OR GREATER. THE VERTICAL | | | HEIGHT SHALL BE MEASURED FROM THE TOP OF THE CEILING | | | FRAMING MEMBERS TO THE UNDERSIDE OF THE ROOF FRAMING | | | MEMBERS. | | | THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 | | | INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE | | | LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE | | | LOCATION. WHEN LOCATED IN A WALL, THE OPENING SHALL BE | | | A MINIMUM OF 22 INCHES WIDE BY 30 INCHES HIGH. WHEN THE | | | ACCESS IS LOCATED IN A CEILING, MINIMUM UNOBSTRUCTED | | | HEADROOM IN THE ATTIC SPACE SHALL BE 30 INCHES (762 MM) | | | AT SOME POINT ABOVE THE ACCESS MEASURED VERTICALLY FROM | | | THE BOTTOM OF CEILING FRAMING MEMBERS. SEE SECTION | | | M1305.1.3 FOR ACCESS REQUIREMENTS WHERE MECHANICAL | | | EQUIPMENT IS LOCATED IN ATTICS. | | | | | | 7) ON SHEET S-20, THE INCORRECT EDITIONS OF ACI AND TMS | | | ARE REFERENCED. THE 2008 EDITIONS ARE THE ONES | | | REFERENCED IN CHAPTER 43 OF THE 2010 FBC. | | | | | | 8) SUBMIT TWO COPIES OF THE EVALUATION REPORT FOR THE | | | SPRAY FOAM INSULATION THAT WILL BE INSTALLED. FBC-R316 | | | | | | 9) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF | | | THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES, | | | STRUCTURAL MULLIONS AND EXTERIOR DOOR TYPES. | | | -THE FOLLOWING IS A LINK TO THE MIAMI - DADE PRODUCT | | | APPROVAL WEBSITE. | | | HTTP://WWW.MIAMIDADE.GOV/BUILDING/PC-SEARCH_APP.ASP | | | -THE FOLLOWING IS A LINK TO THE FLORIDA PRODUCT | | | APPROVAL WEBSITE. | | | HTTPS://FLORIDABUILDING.ORG/PR/PR_APP_SRCH.ASPX | | | | | | 10) THE FOLLOWING CONNECTORS DO NOT HAVE THEIR PRODUCT | | | APPROVAL NUMBERS LISTED ON THE PLANS AND WILL REQUIRE | | | PRODUCT APPROVALS TO BE SUBMITTED IF THEY ARE NOT | | | PROVIDED ON THE PLANS: HUS 210, THA 413 AND LTT19. | | | | | | 11) SHOP DRAWING SUBMITTALS WILL BE REQUIRED FOR THE | | | METAL BALCONY GUARDS. FBC-R 312 & R 301.5 | | | | | | 12) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE | | | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER | | | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN | | | ADDRESSED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-05-09 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-05-09 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-05-09 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-04-22 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-04-22 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-04-22 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2015-04-22 09:00:48 | 4/22/2015 | | | PROJECT: 235 BELMONTE | | | PERMIT#: 15020227 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) INDICATE THE LOCATION ON THE BUILDING(S) ALL | | | ELECTRICAL PANELS, ELECTRICAL SERVICE ENTANCE | | | SWITCHGEAR AND EQUIPMENT SUCH AS DISCONNECTS FOR A/C | | | EQUIPMENT, WATER HEATERS, POOL EQUIPMENT, IRRIGATION | | | EQUIPMENT, GATE CONTROLLERS, ETC... | | | | | | 2) DISCONNECTING MEANS SHALL BE LOCATED WITHIN SIGHT | | | FROM AND READILY ACCESSIBLE FROM THE AIR-CONDITIONING | | | OR REFRIGERATING EQUIPMENT. THE DISCONNECTING MEANS | | | SHALL BE PERMITTED TO BE INSTALLED ON OR WITHIN THE | | | AIR-CONDITIONING OR REFRIGERATING EQUIPMENT. NEC 440.14 | | | | | | 3) PROVIDE A GFI RECEPTACLE AT AN ACCESSIBLE LOCATION | | | WITHIN SIGHT OF A/C EQUIPMENT.. NEC 210.63 NEC 210.8 | | | | | | 4) VERIFY LUMINAIRES IN CLOTHES CLOSETS SHALL BE | | | INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THE NEC | | | 410.16(A) AND (B). | | | | | | 5) VERIFY SPACING AS REQUIRED. SEE NEC 210.52(A)(1) | | | THROUGH (A)(3). AND NEC 210.52(C)(1) | | | | | | 6) VERIFY ALL HABITABLE ROOMS HAVE A SWITCHED LIGHTING | | | OUTLET. SEE NEC 210.70. PLEASE NOTE A DUPLEX RECEPTACLE | | | THAT IS SWITCHED ENTIRELY AND IS NOT FED WITH A | | | CONTINUOUS HOT FOR AT LEAST ONE HALF OF THE DEVICE, | | | DOES NOT COUNT AS ONE OF THE OUTLETS REQUIRED IN NEC | | | 210.70 | | | | | | 7) OCCUPIABLE BALCONIES AND PORCHES OVER 20 SQ FT MUST | | | HAVE A RECEPTACLE OUTLET GFCI PROTECTED. NEC | | | 210.52(E)(3). | | | | | | 8) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | | ARE REQUIRED FOR GENERATORS. ATS, NG FUEL SYSTEM, FIRE | | | ALARM, ACCESS CONTROL SYSTEM, SECURITY, CCTV, | | | AUDIO/VIDEO, NETWORK, DATA, AND, COMMUNICATION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-03-16 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-03-16 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-03-16 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2015-03-16 11:31:51 | 3/16/2015 | | | PROJECT: 235 BELMONTE | | | PERMIT#: 15020227 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) FBC-R 314, 315 | | | ADD SMOKE DETECTORS AS REQUIRED FOR THE POOL HOUSE AND | | | MAIN HOUSE SLEEPING ROOMS AND ADDITIONAL LANDINGS 1ST | | | AND 2ND FLS . | | | | | | 2) INDICATE CIRCUIT NUMBERS ON THE FLOOR PLANS | | | CORREPSPONDING WITH THE ELECTRICAL PANEL SCHEDULES OCPD | | | AND WIRE SIZES | | | | | | 3) ALL NEW GENERAL PURPOSE OUTLETS MUST BE TAMPER | | | RESISTANT AND AFCI PROTECTED. NEC 210.12, 406.11 | | | | | | 4) ALL EXISTING AREAS NOT INVOLVED IN THE CURRENT SCOPE | | | OF WORK INDICATED ON THESE DESIGN DOCUMENTS SHALL BE IN | | | COMPLIANCE WITH THE FBC- EXISTING CHAPTERS, 6,7,AND 8. | | | | | | 5) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | | ARE REQUIRED FOR GENERATORS. ATS, NG FUEL SYSTEM, FIRE | | | ALARM, ACCESS CONTROL SYSTEM, SECURITY, CCTV, | | | AUDIO/VIDEO, NETWORK, DATA, AND, COMMUNICATION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2015-04-18 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-04-18 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-04-18 |
Time |
07:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2015-02-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-02-12 |
Time |
05:08 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-02-11 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2015-02-11 11:21:49 | 1) INDICATE ON THE PLAN IF THE FIREPLACE IS GAS OR WOOD | | | BURNING. IF IT IS GAS, THE BTU LOAD SHALL BE INCLUDED | | | ON THE GAS DRAWING. WPB AMEND. TO 2010 FBC SEC. | | | 107.2.1. | | | 2) PLANS SHOW A FUTURE GENERATOR. INDICATE ON THE PLAN | | | IF THE GENERATOR WILL BE CONNECTED TO THE NATURAL GAS | | | SYSTEM. IF SO IT SHALL BE INCLUDED ON THE GAS RISER.WPB | | | AMEND. TO 2010 FBC SEC. 107.2.1. | | | 3) SHOW THE LOCATION OF THE GAS METER ON THE PLANS.WPB | | | AMEND. TO 2010 FBC SEC. 107.2.1. | | | 4) SUBMIT MANUF. SPECIFICATION SHEETS/INSTALLATION | | | MANUAL FOR ALL APPLIANCES FOR REVIEW. APPLIANCES SHALL | | | BE LISTED PER 2010 FBCR SEC.G2404.3.WPB AMEND. TO 2010 | | | FBC SEC. 107.2.1. | | | 5) SUBMIT A GAS PLAN SHOWING THE LOCATION OF THE PE GAS | | | PIPE.PE PIPE SHALL BE INSTALLED OUTDOORS UNDERGROUND | | | ONLY PER THE FBCR G2415.15.1. IT APPEARS THAT THE PE | | | PIPE MAY BE RUNNING UNDER THE BUILDING SLAB. | | | 6) THE CSST LINE TO THE COOKTOP SHALL BE A MIN. OF 1" | | | PER THE 2010 FBCR TABLE G 2413.4 (5) FOR A DEVELOPED | | | LENGTH OF 40 FT. | | | 7) SHOW THE CORRESPONDING EHD FOR ALL CSST PIPE SIZES | | | PER 2010 FBCR TABLE G 2413.4 (5). | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-03-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-03-02 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-03-02 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-05-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-12 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-24 |
Time |
06:55 |
Sent To |
|
|
| Notes |
| 2015-04-27 07:01:18 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-04-22 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-04-22 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-04-07 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2015-04-07 17:59:46 | RE-SUBMITTAL SENT TO R30 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-03-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-17 |
Time |
14:08 |
Rev Time |
|
| Received By |
rmcdouga |
Date |
2015-02-06 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-02-07 06:39:14 | INCOMING SENT TO R-27. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2015-05-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-13 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2015-05-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-08 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-08 |
Time |
13:55 |
Sent To |
E |
|
| Notes |
| 2015-05-08 13:56:09 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-04-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-20 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-20 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2015-04-20 10:59:53 | SEE PREVIOUS COMMENTS. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-03-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-16 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-16 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2015-03-16 17:19:25 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-05-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-05-08 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-05-08 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2015-05-08 13:07:52 | APPROVED WITH EXCEPTION. THIS PLAN HAS BEEN APPROVED | | | PROVISIONALLY. FAILURE TO CORRECT THE LISTED | | | DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL | | | RESULT IN FAILED INSPECTION(S) AND ASSESSMENT OF | | | RE-INSPECTION FEE(S). | | | | | | FBC-R - M1305.1.3 APPLIANCES IN ATTICS. | | | ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN | | | OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE | | | ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, BUT | | | NOT LESS THAN 30 INCHES (762 MM) HIGH AND 22 INCHES | | | (559 MM) WIDE AND NOT MORE THAN 6 FEET (1829 MM) LONG | | | MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM | | | THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE | | | CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH CHAPTER 5 | | | NOT LESS THAN 24 INCHES (610 MM) WIDE. A LEVEL SERVICE | | | SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES | | | (762 MM) WIDE SHALL BE PRESENT ALONG ALL SIDES OF THE | | | APPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR ACCESS | | | OPENING DIMENSIONS SHALL BE A MINIMUM OF 20 INCHES BY | | | 30 INCHES (508 MM BY 762 MM), AND LARGE ENOUGH TO ALLOW | | | REMOVAL OF THE LARGEST APPLIANCE. | | | | | | | | | FBC-R - M1305.1.3.1 ELECTRICAL REQUIREMENTS. | | | A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE | | | REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET | | | SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN | | | ACCORDANCE WITH CHAPTER 34. | | | | | | FBC-R - M1305.1.3.2 AIR-HANDLING UNITS. | | | AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS IF THE | | | FOLLOWING CONDITIONS ARE MET: | | | 1. THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | | 2. A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT THE | | | UNIT DOWN WHEN THE CONDENSATION DRAIN IS NOT WORKING | | | PROPERLY. | | | 3. THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | | REPLACE THE AIR HANDLER. | | | 4. A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | | INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS | | | LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL | | | CAPITALS, IN 16 POINT TYPE, WITH THE TITLE AND FIRST | | | PARAGRAPH IN BOLD: | | | | | | NOTICE TO HOMEOWNER | | | | | | A PART OF YOUR AIR CONDITIONING SYSTEM, THE AIR | | | HANDLER, IS LOCATED IN THE ATTIC. FOR PROPER, EFFICIENT | | | AND ECONOMIC OPERATION OF THE AIR CONDITIONING SYSTEM, | | | YOU MUST ENSURE THAT REGULAR MAINTENANCE IS PERFORMED. | | | YOUR AIR CONDITIONING SYSTEM IS EQUIPPED WITH ONE OR | | | BOTH OF THE FOLLOWING: | | | | | | 1) A DEVICE THAT WILL ALERT YOU WHEN THE CONDENSATION | | | DRAIN IS NOT WORKING PROPERLY OR | | | | | | 2) A DEVICE THAT WILL SHUT THE SYSTEM DOWN WHEN THE | | | CONDENSATION DRAIN IS NOT WORKING. | | | | | | TO LIMIT POTENTIAL DAMAGE TO YOUR HOME, AND TO AVOID | | | DISRUPTION OF SERVICE, IT IS RECOMMENDED THAT YOU | | | ENSURE PROPER WORKING ORDER OF THESE DEVICES BEFORE | | | EACH SEASON OF PEAK OPERATION. | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-04-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-04-20 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-04-17 |
Time |
14:29 |
Sent To |
E |
|
| Notes |
| 2015-04-20 11:21:56 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. IN ADDITION TO | | | THE NAME AND SIGNATURE, SPECIFY THE MECHANICAL | | | CONTRACTOR'S LICENSE NUMBER ON THE PLANS. | | | | | | 2) FBC ENERGY CONSERVATION - SECT. 103.2.3.2 CODE | | | COMPLIANCE CERTIFICATION. THE BUILDING?S OWNER, THE | | | OWNER?S ARCHITECT, OR OTHER AUTHORIZED AGENT LEGALLY | | | DESIGNATED BY THE OWNER SHALL CERTIFY THAT THE BUILDING | | | IS IN COMPLIANCE WITH THE CODE, AS PER SECTION 553.907, | | | FLORIDA STATUTES, PRIOR TO RECEIVING THE PERMIT TO | | | BEGIN CONSTRUCTION OR RENOVATION. OWNER/AGENT IS | | | REQUIRED TO SIGN THE ENERGY FORM. | | | | | | 3) THE FIRST THREE MECHANICAL NOTES ON THE SECOND | | | MECHANICAL SHEET ARE JUMBLED AND ARE NOT ACCEPTABLE FOR | | | PUBLIC RECORD. FBC 107.2.1.4 QUALITY OF BUILDING PLANS. | | | BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH | | | SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE | | | MEDIUM. THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM | | | SIZE, SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED | | | TO RECORDS MANAGEMENT. | | | | | | 4) FBC-R - M1305.1.3 APPLIANCES IN ATTICS. | | | ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN | | | OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE | | | ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, BUT | | | NOT LESS THAN 30 INCHES (762 MM) HIGH AND 22 INCHES | | | (559 MM) WIDE AND NOT MORE THAN 6 FEET (1829 MM) LONG | | | MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM | | | THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE | | | CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH CHAPTER 5 | | | NOT LESS THAN 24 INCHES (610 MM) WIDE. A LEVEL SERVICE | | | SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES | | | (762 MM) WIDE SHALL BE PRESENT ALONG ALL SIDES OF THE | | | APPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR ACCESS | | | OPENING DIMENSIONS SHALL BE A MINIMUM OF 20 INCHES BY | | | 30 INCHES (508 MM BY 762 MM), AND LARGE ENOUGH TO ALLOW | | | REMOVAL OF THE LARGEST APPLIANCE. | | | FBC-R - M1305.1.3.1 ELECTRICAL REQUIREMENTS. | | | A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE | | | REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET | | | SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN | | | ACCORDANCE WITH CHAPTER 34. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-03-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-16 |
Time |
18:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-16 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2015-03-16 18:54:36 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC-R - M1401.3 SIZING. HEATING AND COOLING | | | EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS | | | CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER | | | APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. | | | PROVIDE EQUIPMENT SIZING CALCULATIONS FOR THE MAIN | | | HOUSE ADDITION. | | | | | | 2) FBC-R - M 1602.4 PROVIDE BALANCED RETURN AIR. | | | RESTRICTED RETURN AIR OCCURS IN BUILDINGS WHEN RETURNS | | | ARE LOCATED IN CENTRAL ZONES AND CLOSED INTERIOR DOORS | | | IMPEDE AIR FLOW TO THE RETURN GRILL OR WHEN CEILING | | | SPACES ARE USED AS RETURN PLENUMS AND FIRE WALLS | | | RESTRICT AIR MOVEMENT FROM ONE PORTION OF THE RETURN | | | PLENUM TO ANOTHER. PROVISIONS SHALL BE MADE IN BOTH | | | RESIDENTIAL AND COMMERCIAL BUILDINGS TO AVOID | | | UNBALANCED AIR FLOWS AND PRESSURE DIFFERENTIALS CAUSED | | | BY RESTRICTED RETURN AIR. PRESSURE DIFFERENTIALS ACROSS | | | CLOSED DOORS WHERE RETURNS ARE CENTRALLY LOCATED SHALL | | | BE LIMITED TO 0.01 INCH WC (2.5 PASCALS) OR LESS. | | | PRESSURE DIFFERENTIALS ACROSS FIRE WALLS IN CEILING | | | SPACE PLENUMS SHALL BE LIMITED TO 0.01 INCH WC (2.5 | | | PASCALS) BY PROVIDING AIR DUCT PATHWAYS OR AIR TRANSFER | | | PATHWAYS FROM THE HIGH PRESSURE ZONE TO THE LOW ZONE. | | | EXCEPTIONS: | | | 1. TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE | | | RETURN TRANSFER 11/2 TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT ENTERING THE ROOM OR | | | SPACE IT IS SERVING AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCH UNDERCUT TO ACHIEVE PROPER RETURN | | | AIR BALANCE. | | | 2. TRANSFER GRILLES SHALL USE 50 SQUARE INCHES (OF | | | GRILLE AREA) TO 100 CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND USING AN | | | UNRESTRICTED 1 INCH UNDERCUTTING OF DOORS TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | 3. HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET THESE | | | REQUIREMENTS FOR PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY ROOMS, | | | EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE SHALL | | | BE INCLUDED. | | | (MAIN HOUSE ADDITION) THE RETURN AIR DUCT FROM THE | | | MASTER BEDROOM IS UNDER SIZED. ALL SUPPLY AIR INTO THE | | | MASTER SUITE SHALL BE ACCOUNTED FOR. | | | (POOL HOUSE) THE AIR HANDLER CLOSET IS LOCATED INSIDE | | | OF A CLOTHES CLOSET AT ONE END OF THE POOL HOUSE. THERE | | | IS A SOLID DOOR ON THE CLOTHS CLOSET AND THERE ARE | | | OTHER DOORS THAT EFFECTIVELY WILL ISOLATE THE UNIT FROM | | | THE REST OF THE STRUCTURE INCLUDING THE BEDROOM ON THE | | | OPPOSITE END. SHOW HOW THE BALANCED AIR REQUIREMENTS | | | WILL BE MET. | | | | | | 3) THE HEATING AND COOLING EQUIPMENT SCHEDULE ON THE | | | PLANS DOES NOT MATCH THE ENERGY FORMS OR THE SIZING | | | CALCULATIONS (POOL HOUSE) THAT WERE SUBMITTED. FOR THE | | | POOL HOUSE THE PLANS HAVE 2 TONS AND THE CALCULATION | | | AND ENERGY FORM HAS 2.5 TONS. FOR THE MAIN HOUSE | | | ADDITION THE PLANS HAVE 3.5 TONS AND THE ENERGY FORM | | | HAS 3 TONS. FBC 107.2.1 | | | | | | 4) THE ENERGY FORM FOR THE POOL HOUSE IS REQUIRED TO BE | | | SIGNED BY THE OWNER/AGENT. FBC ENERGY CONSERVATION | | | 103.2.3.2 | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-04-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-04-18 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-04-18 |
Time |
05:37 |
Sent To |
|
|
| Notes |
| 2015-04-23 03:54:05 | APPROVED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-02-11 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-02-11 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-02-11 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-05-11 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-05-11 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-05-11 |
Time |
11:28 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-03-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-03-02 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-03-02 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2015-02-10 10:48:44 | 2-10-15 |
|
|