Plan Review Details - Permit 15011082
| Plan Review Stops For Permit 15011082 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-03-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-25 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-24 |
Time |
18:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-03-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-16 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-16 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2015-03-16 15:29:16 | PLAN REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THE STRUCTURAL WINDOW MULLIONS. DCA RULE 9N-3 | | | | | | 2) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | | STORM PANELS AND THE 9 X 7 SECTIONAL GARAGE DOOR HAVE | | | INSTALLATION DRAWINGS THAT ARE MISSING INFORMATION. THE | | | DRAWINGS WERE NOT SHRUNK TO FIT ON THE 8.5" X 11" SIZE | | | PAPER AND ARE MISSING REQUIRED INFORMATION. | | | | | | 3) FBC - R 301.2.1.2 SUBMIT TWO COPIES OF AN | | | INSTALLATION SCHEDULE AND KEY PLAN FOR THE STORM | | | PANELS. SPECIFY THE OPENING SIZE, THE WIND PRESSURES, | | | TYPE OF ANCHOR, ANCHOR SPACING, EDGE DISTANCE, PANEL | | | LENGTH, PANEL SPAN, SEPARATION DISTANCE FROM PANEL TO | | | GLASS AND THE APPLICABLE SECTION NUMBER FROM THE | | | INSTALLATION DRAWINGS. I HAVE INCLUDED A LINK TO THE | | | CONSTRUCTION SERVICES DEPARTMENT SITE THAT HAS MANY OF | | | THE RELATED FORMS INCLUDING | | | THE SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE | | | DEVICES. | | | HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/ | | | | | | 4) SPECIFY THE SPACING OF THE #14 WOOD SCREW ANCHORS. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-24 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-24 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2015-02-24 08:52:56 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE PRODUCT | | | APPROVALS FOR THE NEW SINGLE HUNG WINDOWS AND | | | STRUCTURAL MULLIONS. | | | | | | 2) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | | STORM PANELS AND THE 9 X 7 SECTIONAL GARAGE DOOR HAVE | | | INSTALLATION DRAWINGS THAT ARE MISSING INFORMATION. IT | | | APPEARS THAT THE DRAWINGS WERE NOT SHRUNK TO FIT ON THE | | | 8.5" X 11" SIZE PAPER. | | | | | | 3) FBC - R 301.2.1.2 SUBMIT TWO COPIES OF AN | | | INSTALLATION SCHEDULE AND KEY PLAN FOR THE STORM | | | PANELS. SPECIFY THE OPENING SIZE, THE WIND PRESSURES, | | | TYPE OF ANCHOR, ANCHOR SPACING, EDGE DISTANCE, PANEL | | | LENGTH, PANEL SPAN, SEPARATION DISTANCE FROM PANEL TO | | | GLASS AND THE APPLICABLE SECTION NUMBER FROM THE | | | INSTALLATION DRAWINGS. I HAVE INCLUDED A LINK TO THE | | | CONSTRUCTION SERVICES DEPARTMENT SITE THAT HAS MANY OF | | | THE RELATED FORMS INCLUDING | | | THE SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE | | | DEVICES. | | | HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/ | | | | | | 4) SHOW THAT THE EGRESS DOOR REQUIRED BY FBC - R311.1 | | | WILL REMAIN IN COMPLIANCE WITH FBC- R311.2 AND BE | | | READILY OPENABLE FROM INSIDE THE DWELLING WITHOUT THE | | | USE OF A SPECIAL KEY OR SPECIAL KNOWLEDGE OR EFFORT | | | WHEN THE STORM PANELS ARE IN PLACE. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-03-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-03-16 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-03-06 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2015-03-09 08:44:21 | RE-SUBMITTAL SENT TO ROBERT MCDOUGAL FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-24 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-01-30 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2015-01-30 08:49:48 | MISC 1 | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy