Plan Review Details - Permit 15011019
Plan Review Stops For Permit 15011019
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-03-13 Cont ID  
Sent By   Date 2015-03-13 Time 17:14 Rev Time 0.00
Received By jwitmer Date 2015-03-12 Time 08:31 Sent To  
Notes
2015-03-12 08:31:373/12 CALLED THE DESIGNER OF RECORD, STILL NEED THE
 LINTEL PRODUCT APPROVAL, NOT INCLUDED IN THIS PACKAGE.
 JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-02-06 Cont ID  
Sent By jwitmer Date 2015-02-06 Time 09:36 Rev Time  
Received By jwitmer Date 2015-02-06 Time 08:30 Sent To  
Notes
2015-02-06 09:36:36BUILDING PLAN REVIEW
 PERMIT: 15011019
 ADD: 122 LINDA LN.
 CONT: FLORIDA BUILDING & SUPPLY
 TEL: ( 305)885-4388
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 IMPORTANT NOTICE: EFFECTIVE MARCH 2, 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE
  
  
 1ST REVIEW
 DATE: FRI. FEB. 06/2015
 ACTION: DENIED
  
 1) THE PLANS SUBMITTED FOR THE CUTTING IN OF OPENING
 FOR NEW FRENCH DOORS & SIDELIGHTS IS A DESIGN BY JOHN
 M. NOSSEL, ARCHITECT. PLANS ARE NOT SIGNED NOR SEALED.
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
 PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE
 DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. FL ADMIN
 CODE 61G16.003 ARCHITECTS.
  
 2) ONLY ONE SET OF PLANS AND PRODUCT APPROVALS WERE
 SUBMITTED FOR PERMIT. 2010 WEST PALM BEACH AMENDMENTS
 TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION, 107.1 GENERAL. SUBMITTAL DOCUMENTS
 CONSISTING OF CONSTRUCTION DOCUMENTS, REPORT AND OTHER
 DATA SHALL BE SUBMITTED IN TWO OR MORE SETS WITH EACH
 PERMIT APPLICATION.
  
 3) THE SUBMITTED PLAN IS A REDUCTION OF A PLANS, PLEASE
 COMPLY WITH 2010 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION,
 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
  
 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
 PLEASE IDENTIFY THE WIDTH, HEIGHT, TYPE OF GLAZING FOR
 DOORS AND SIDE LITES, THE PRESSURES MAY OR MAY NOT MEET
 THE REQUIRED PRESSURES FOR A D EXPOSURE AT 22.5 MEAN
 ROOF HEIGHT.
  
 5) MISSING REPORT FOR PRODUCT APPROVAL: FLORIDA
 DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010
 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS
 THAT WILL REQUIRE PRODUCT APPROVALS: (31)(G) STRUCTURAL
 COMPONENTS, LINTELS.
  
 6) SHEET A-1. PROVIDE THE ALLOWABLE LOADS THIS LINTEL
 WILL BE ABLE TO CARRY AND THE LOADS THAT ARE BEING
 CARRIED BY THE GIRDER 7'-0" BACK FROM THE CORNER OF THE
 BUILDING, HIPPED ROOF TRUSS SYSTEM. PROVIDE ENGINEERING
 IN COMPLIANCE WITH 2010 FBC-R 609.6.3.1 & R609.6.3.2
 WITH THE ADDITIONAL POINT LOAD OF THE GIRDER.
  
 7) SHEET A-1 THE SECTION THROUGH THE EXTERIOR WALL
 APPEARS TO BE THE LINTEL WHERE THE BOND BEAM WOULD BE
 AND NO CONNECTION TO THE 8X8 BEAM BELOW. APPEARS TO BE
 REVERSED. THE BOND BEAM AND LINTEL LOADS MAY REQUIRE
 HAIR PINS FOR THE ADDITIONAL LOADING OF THE TRUSS
 GIRDER , PLEASE PROVIDE
 COMPLIANCE WITH ENGINEERING IN COMPLIANCE WITH 2010
 FBC-R 609.6.3.1 & R609.6.3.2 WITH THE ADDITIONAL POINT
 LOAD OF THE GIRDER.
  
 8) NOTE BUCK DETAIL NEED TO COMPLY WITH 2010 FBC-R
 612.10.2.1 WINDOW / DOOR BUCKS SHALL EXTEND BEYOND THE
 INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS PROVIDED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-03-11 Cont ID  
Sent By jwitmer Date 2015-03-11 Time 12:37 Rev Time 0.00
Received By dhayes Date 2015-03-11 Time 12:36 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-03-13 Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By dhayes Date 2015-03-11 Time 12:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-02-06 Cont ID  
Sent By   Date 2015-02-06 Time   Rev Time  
Received By   Date 2015-02-06 Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved