Plan Review Details - Permit 15010952
Plan Review Stops For Permit 15010952
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-07-07 Cont ID  
Sent By jwitmer Date 2015-07-07 Time 16:52 Rev Time 0.00
Received By jwitmer Date 2015-07-07 Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-04-08 Cont ID  
Sent By jwitmer Date 2015-04-08 Time 06:27 Rev Time 0.00
Received By jwitmer Date 2015-04-08 Time 06:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-02-04 Cont ID  
Sent By jwitmer Date 2015-02-04 Time 09:20 Rev Time 0.00
Received By jwitmer Date 2015-02-04 Time 06:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-07-20 Cont ID  
Sent By albarran Date 2015-07-20 Time 14:54 Rev Time 0.00
Received By albarran Date 2015-07-20 Time 14:03 Sent To I
Notes
2015-07-20 14:56:24PASSED ELECTRICAL REVIEW WITH EXCEPTIONS AS NOTED ON
 PAGE E1.
 1.MISSING THE REQUIRED SIGN OUTLET BY THE ENTRANCE
 DOORS AS PER NEC 600.5
 2. NOTE ENTERED FOR FIRE RATED MEMBRANE PENETRATIONS.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-05-11 Cont ID  
Sent By albarran Date 2015-05-11 Time 14:20 Rev Time 0.00
Received By albarran Date 2015-05-11 Time 13:54 Sent To I
Notes
2015-05-11 14:25:12DISPOSITION AND RESPECTIVE COMMENTS FOR THE ELECTRICAL
 PLANS REVIEW
 PERMIT #:15010952
 DATE: 5/11/15
 APPLICABLE CODES: FBC 2010; WPB AMENDMENTS TO FBC 2010
 CHAPTER 1; NEC 2008
 REVIEW CYCLE:2
 ACTION:DENIED
  
 ALL OF THE PREVIOUSLY ADDRESSED COMMENTS HAVE BEEN
 SATISFACTORILY ADDRESSED AND CORRECTED, BUT BECAUSE
 THIS IS A BLDG. OF GREATER THAN 5000 SQ. FT. COMPLIANCE
 WITH FBC 2010 ENERGY CONSERVATION REQUIREMENTS SHALL
 APPLY. PLEASE REVISE YOUR PLANS TO INCLUDE ALL
 REQUIREMENTS OF SUCH.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-02-09 Cont ID  
Sent By dhayes Date 2015-02-09 Time 16:18 Rev Time 0.00
Received By dhayes Date 2015-02-09 Time 14:46 Sent To  
Notes
2015-02-09 15:05:242/9/2015
 PROJECT: 804 S. DIXIE
 PERMIT#: 15010952
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) PROVIDE SYSTEM VOLTAGE AT ELECTRICAL SERVICE RISER
 AND LOAD CALCULATION. PANEL SCHEDULES ARE NOTED AS
 120/208VOLT 3PHASE 4 WIRE, THE LOAD CALCULATION USES
 230VOLT 1PHASE? PROVIDE CONSYSTANCY WITH SYSTEM VOLTAGE
 THROUGHOUT. WPB AMENDMENTS TO FBC 107.2
  
 2) ELECTRICAL RISER INDICATES 3,3/0 AND 10,#2 CU IN 2"
 RIDGED CONDUIT FEEDING A 100AMP ELECTRICAL PANEL. THIS
 APPEARS TO BE A POSSIBLE TYPO BUT MAKES NO SENSE AND
 NEEDS TO BE ADDRESSED. THE SAME IS NOTED FROM THE
 SECOND 100AMP DISCONNECT FEEDING THE OTHER ELECTRICAL
 PANEL. PROVIDE A REVISED RISER DIAGRAM WITH ACTUAL WIRE
 SIZES TYPE AND QUANTITY. NEC 215.2 , 215.5 5
  
 3) PROVIDE FOR EMERGENCY AND EXIT LIGHTING ON THE
 ELECTRICAL FLOOR PLAN WHERE REQUIRED BY NEC 700.16
 CIRCUIT EMERGENCY AND EXIT LIGHTING ON THE ELECTRICAL
 FLOOR AND PROVIDE THE CIRCUIT NUMBER IN THE PANEL
 SCHEDULE FEEDING THE EMERGENCY EXIT LIGHTING. NEC
 700.12
  
 4) ELECTRIC DRINKING FOUNTAINS SHALL BE PROTECTED WITH
 GROUND FAULT CIRCUIT INTERRUPTER PROTECTION. NEC 422.52
  
 5) PANEL A IS IDENTIFIED AS A 100AMP PANEL. THE LOAD
 CALCULATION INDICATES A 116AMP LOAD ON PANEL A. REVISE
 THE RISER AND PANEL OR THE LOAD. NEC 215.2
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2015-07-01 Cont ID  
Sent By cranford Date 2015-07-01 Time 15:35 Rev Time 0.00
Received By cranford Date 2015-07-01 Time 15:25 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2015-05-08 Cont ID  
Sent By cranford Date 2015-05-08 Time 09:28 Rev Time 0.00
Received By cranford Date 2015-05-08 Time 09:25 Sent To E
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2015-03-16 Cont ID  
Sent By cranford Date 2015-03-16 Time 15:31 Rev Time 0.00
Received By cranford Date 2015-03-16 Time 15:12 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2015-06-29 Cont ID  
Sent By pleduc Date 2015-06-29 Time   Rev Time 0.00
Received By pleduc Date 2015-06-29 Time 13:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-04-03 Cont ID  
Sent By pleduc Date 2015-04-03 Time   Rev Time 0.00
Received By pleduc Date 2015-04-03 Time 13:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-02-06 Cont ID  
Sent By pleduc Date 2015-02-06 Time   Rev Time 0.00
Received By pleduc Date 2015-02-06 Time 09:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-07-20 Cont ID  
Sent By albarran Date 2015-07-20 Time 15:05 Rev Time 0.00
Received By albarran Date 2015-05-20 Time 16:05 Sent To  
Notes
2015-07-20 15:09:297/20/15 - PASSED ELECTRICAL AND FINAL REVIEW.
 CONTRACTOR NOTIFIED VIA VOICE MAIL. SENT TO SMALL READY
 BIN "B". MA
2015-05-20 11:41:21C12

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-05-11 Cont ID  
Sent By albarran Date 2015-05-11 Time 14:27 Rev Time 0.00
Received By albarran Date 2015-04-01 Time 16:55 Sent To  
Notes
2015-05-11 14:32:59THIS APPLICATION APPEARS TO HAVE FAILED MECHANICAL AND
 ZONING AS WELL AS ELECTRIC THE SECOND TIME AROUND.. I
 TRIED TO CONTACT CONTRACTOR AT THE NUMBER MENTIONED ON
 THE APPLICATION BUT WAS UNABLE TO. I COULD NOT
 UNDERSTAND THE EMAIL ADDRESS. THIS FILE WAS SENT TO
 SMALL DENIED "B".
2015-04-01 16:56:28C12

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-30 Cont ID  
Sent By skennedy Date 2015-03-30 Time 16:03 Rev Time 0.00
Received By skennedy Date 2015-01-28 Time 11:36 Sent To  
Notes
2015-01-28 11:36:24C12
  
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2015-07-29 Cont ID  
Sent By hmoser Date 2015-07-29 Time 14:48 Rev Time 0.00
Received By hmoser Date 2015-07-29 Time 14:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2015-07-07 Cont ID  
Sent By ccole Date 2015-07-07 Time 14:33 Rev Time 0.00
Received By ccole Date 2015-07-07 Time 14:33 Sent To  
Notes
2015-07-07 14:59:313RD REVIEW; FBC 2010 MECHANICAL
  
 1) SHEET MP-1: REMOVE THE CUT AND PASTE AHU-1 MOUNTING
 DETAIL SHOWING A GARAGE INSTALLATION AND INACCURATE
 SUPPLY DUCT SIZE NOT RELEVENT TO THIS PROJECT.
 2) MP-1: THE CLOSETS SHOWN ON THE PLAN ARE DEFINED AS
 PLENUMS IN ACCORDANCE WITH SECTION 202 AND MUST BE
 ENCLOSED WITH NON-COMBUSTIBLE MATERIALS PER SECTION
 602.2. PLEASE INDICATE THE TYPE OF MATERIAL USED TO
 FORM THE PLENUM, AND VERIFY THE LOUVERED CLOSET DOORS
 ARE CONSTRUCTED OF METAL.
 3) MP-1: SHOW THE REQUIRED 4" MINIMUM CLEARANCE AROUND
 ALL SIDES OF THE AIR HANDLERS- SECFTION 603.1.3.
 4) MP-1: VERIFY THAT THE LOUVERED DOORS ARE PROVIDING A
 MINIMUM OF 27 SQUARE INCHES OF RETURN AIR OPENING FOR
 PROPER AIR BALANCING- SECTION 601.4.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-04-16 Cont ID  
Sent By hmoser Date 2015-04-16 Time 11:04 Rev Time 0.00
Received By hmoser Date 2015-04-16 Time 11:04 Sent To  
Notes
2015-04-16 11:05:49ONLY ONE PLAN SUBMITTED HM.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-03-10 Cont ID  
Sent By hmoser Date 2015-03-10 Time 09:31 Rev Time 0.00
Received By hmoser Date 2015-03-10 Time 08:41 Sent To  
Notes
2015-03-10 09:31:15PLAN DENIED
 1) PROVIDE ENERGY CALCULATIONS PER SECTION 321.1
 LOAD CALCULATIONS 2010 FBC (M) OR 503.2.1
 CALCULATIONS OF HEATING AND COOLING. 2010
 FLORIDA ENERGY CODE.
 2) REFER TO SECTION 503.2.5.4 SHUTOFF DAMPER
 CONTROLS 2010 FLORIDA ENERGY CODE.
 3) SIZE FRESH AIR DUCT. PER SECTION 107 FBC 2010
 4) REFER TO SECTION 601.4 BALANCED RETURN AIR
 2010 FBC (M)
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 3 Status P Date 2015-07-11 Cont ID  
Sent By tklarge Date 2015-07-11 Time 07:40 Rev Time 0.00
Received By tklarge Date 2015-07-11 Time 07:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-04-29 Cont ID  
Sent By tklarge Date 2015-04-29 Time 08:38 Rev Time 0.00
Received By tklarge Date 2015-04-28 Time 15:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-01-30 Cont ID  
Sent By tklarge Date 2015-01-30 Time 11:55 Rev Time 0.00
Received By tklarge Date 2015-01-30 Time 11:38 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2015-07-14 Cont ID  
Sent By aaponte Date 2015-07-14 Time 13:59 Rev Time 0.00
Received By aaponte Date 2015-07-14 Time 13:59 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2015-04-24 Cont ID  
Sent By aaponte Date 2015-04-24 Time 09:23 Rev Time 0.00
Received By aaponte Date 2015-04-24 Time 09:23 Sent To  
Notes
2015-04-24 09:24:401. A 5' LANDSCAPE BUFFER IS REQUIRED ON THE WEST SIDE
 OF THE HANDICAP SPACE.
 2. PROPOSED SABAL PALM NEXT TO CONCRETE APRON SHALL BE
 REPLACED BY A SMALL SHADE OR FLOWERING TREE.
 3. PLANTING SHALL BE PROTECTED FROM VEHICULAR TRAFFIC
 WITH A RAISED EDGE OR CURB.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.

Review Stop Z ZONING
Rev No 1 Status F Date 2015-02-12 Cont ID  
Sent By aaponte Date 2015-02-12 Time 10:37 Rev Time 0.00
Received By aaponte Date 2015-02-12 Time 10:18 Sent To  
Notes
2015-02-12 10:31:231. PARKING AREAS SHALL BE SCREENED BY A MINIMUM 5 FOOT
 WIDE LANDSCAPE BUFFER WHICH INCLUDES HEDGES AND TREES
 EVERY 30 FEET. IN THIS CASE, ONE TREE IS REQUIRED ON
 NORTH , WEST AND SOUTH SIDE OF PARKING. A TREE CAN BE
 REPLACED BY TWO PALMS IF NEEDED ON THE NORTH AND SOUTH
 SIDE.
 2. ALL LANDSCAPED AREAS SHALL BE IRRIGATED.
 3. PLEASE DISCUSS WITH THE ENGINEERING DEPARTMENT THE
 NEED TO REMOVE THE DROP-CURB ON THE FRONT OF THE
 PROPERTY, AND LIMIT THE DRIVEWAY TO THE ACCESS POINT
 ONLY. PLEASE CONTACT UYEN KHANH FOR FURTHER ADVISE ON
 THIS MATTER (561-4941040).
 4. PARKING STRIPPING SHALL FOLLOW CITY STANDARDS.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.
2015-02-02 15:30:142/2/15