Plan Review Details - Permit 15010809
Plan Review Stops For Permit 15010809
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2015-06-24 Cont ID  
Sent By jwitmer Date 2015-06-24 Time 07:16 Rev Time 0.00
Received By jwitmer Date 2015-06-24 Time 06:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-04-30 Cont ID  
Sent By jwitmer Date 2015-04-30 Time 07:15 Rev Time 0.00
Received By jwitmer Date 2015-04-30 Time 06:46 Sent To  
Notes
2015-04-30 07:03:23BUILDING PLAN REVIEW
 PERMIT: 15010809
 ADD: 1813 N. TAMARIND AVE.
 CONT: FIC CONSTRUCTION
 TEL: (407)744-5664
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: THURS. APRIL 30/ 2015
  
 NOTICE !!!!!!!!!!!!!NOTICE!!!!!!!!!!!!!!: CHAPTER
 553.80(2)(B) FLORIDA STATUTES STATES THAT A LOCAL
 GOVERNMENT SHALL IMPOSE A FEE OF FOUR TIMES THE FEE FOR
 PLAN REVIEW, IF PLANS ARE REJECTED (3) OR MORE TIMES
 FOR REPEATED FAILURE TO CORRECT A CODE VIOLATION.
 -------------------------------------------------------
 -------------------------------------------------------
 -------------------------------------------------------
 -------------------------------------------------------
 ----------------------------
 ACTION: DENIED
  
 1) COMPLIED. SINGLE FAMILY DWELLING UNIT. PARTIAL
 CHANGE OF OCCUPANCY.
  
 2) COMPLIED. 5/08/2015 THE BUILDING OFFICIAL ROBERT
 BROWN ACCEPTTED THE LETTER FROM ARCHITECT KARIN
 MANNCHEN UNDER THE 2010 FL. EXIST. BUILDING CODE 101.5
 EXCEPTION FOR 1 HOUR RATING BETWEEN THE MERCANTILE AND
 R3 RESIDENCE ABOVE.
  
 3) NOTE FOR CONTRACTOR, CONTRACTORS RESPONSIBILITY:
 ASBESTOS SURVEY
 RESIDENTIAL LEAD BASED PAINT HAZARD ACT OF 1992 AMENDED
 4/ 21/ 2005 FEDERAL ACT.
  
 2010 FBC-EXISTING BUILD. CODE 502.2 NEW AND REPLACEMENT
 MATERIALS. EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY
 THIS CODE, MATERIALS PERMITTED BY THE APPLICABLE CODE
 FOR NEW CONSTRUCTION SHALL BE USED. LIKE MATERIALS
 SHALL BE PERMITTED FOR REPAIRS AND ALTERATIONS,
 PROVIDED NO DANGEROUS OR UNSAFE CONDITION, AS DEFINED
 IN CHAPTER 2, IS CREATED. HAZARDOUS MATERIALS, SUCH AS
 ASBESTOS AND LEAD-BASED PAINT, SHALL NOT BE USED WHERE
 THE CODE FOR NEW CONSTRUCTION WOULD NOT PERMIT THEIR
 USE IN BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND
 LOCATION.
  
 4A) COMPLIED.
  
 4B) COMPLIED. 2304.9.6 LOAD PATH. WHERE WALL FRAMING
 MEMBERS ARE NOT CONTINUOUS FROM FOUNDATION SILL TO
 ROOF, THE MEMBERS SHALL BE SECURED TO ENSURE A
 CONTINUOUS LOAD PATH. WHERE REQUIRED, SHEET METAL
 CLAMPS, TIES OR CLIPS SHALL BE FORMED OF GALVANIZED
 STEEL OR OTHER APPROVED CORROSION-RESISTANT MATERIAL
 NOT LESS THAN 0.040 INCH (1.01 MM) NOMINAL THICKNESS.
 THE UPDATED PLANS SHOW STRAPS FROM THE POST TO FLOOR
 JOIST BUT NOT TO THE ROOF CEILING JOIST.
  
 4C) COMPLIED.
  
 4D) COMPLIED.
  
 5) COMPLIED.
  
 6) 3RD REQUEST. WINDOW NOTE # 1 INDICATES THE
 INSTALATION OF NEW WINDOWS WITH A COMPABLE OPTION FOR
 OPERABLE SHUTTERS, NO OPTIONS!!!! ITS A EITHER OR NO
 OPTIONS. 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 SUCH
 DRAWINGS AND SPECIFICATIONS SHALL CONTAIN INFORMATION,
 IN THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION.
  
 7) 3RD REQUEST. 2010 FBC-B 1609.1.2 PROTECTION OF
 OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING
  
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS & MULLIONS
 (E) STORM SHUTTERS
  
 8) 3RD REQUEST. 2010 FBC 107.3.4.1 PRODUCT APPROVALS.
 THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE
 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-03-25 Cont ID  
Sent By jwitmer Date 2015-03-25 Time 16:58 Rev Time 0.00
Received By jwitmer Date 2015-03-25 Time 14:33 Sent To  
Notes
2015-03-25 16:58:49BUILDING PLAN REVIEW
 PERMIT: 15010809
 ADD: 1813 N. TAMARIND AVE.
 CONT: FIC CONSTRUCTION
 TEL: (407)744-5664
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. JAN. 29/ 2015
 ACTION: DENIED
  
 1) COMPLIED. SINGLE FAMILY DWELLING UNIT. PARTIAL
 CHANGE OF OCCUPANCY.
  
 2) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION: 107.3.5
 MINIMUM PLAN REVIWE CRITERIA FOR COMMERCIAL BUILDINGS.
 107.3.5.1 COMMERCIAL BUILDINGS:
 2.2 SEMI- COMPLIED. MIXED USE/ UPSTAIRS SINGLE FAMILY
 DWELLING UNIT. DOWNSTAIRS OCCUPANCY GROUP NOT PROVIDED.
 PROPERTY APPRAISER OFFICE STORE/ OFFICE.
  
 2.3 2ND REQUEST . MINIMUM TYPE OF CONSTRUCTION SHALL BE
 DETERMINED (SEE TABLE 503).
 2.4 FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL
 INCLUDE THE FOLLOWING COMPONENTS: FIRE-RESISTANT
 SEPARATIONS SEE FBC-B 439.3 HORIZONTAL SEPERATION.
 2010 EXST. BLDG. CODE 912.1.1.2 CHANGE OF OCCUPANCY
 CLASSIFICATION WITH SEPARATION. WHERE A PORTION OF AN
 EXISTING BUILDING THAT IS CHANGED TO A NEW OCCUPANCY
 CLASSIFICATION AND THAT PORTION IS SEPARATED FROM THE
 REMAINDER OF THE BUILDING WITH FIRE BARRIERS HAVING A
 FIRE-RESISTANCE RATING AS REQUIRED IN THE FLORIDA
 BUILDING CODE, BUILDING FOR THE SEPARATE OCCUPANCY,
 THAT PORTION SHALL COMPLY WITH ALL THE REQUIREMENTS OF
 CHAPTER 8 FOR THE NEW OCCUPANCY CLASSIFICATION AND WITH
 THE REQUIREMENTS OF THIS CHAPTER.
 FBC-B 707.3.9 & TABLE 707.3.9. REQUIRES 2 HOUR FLOOR
 CEILING ASSEMBLY, HORIZONTAL ASSEMBLIES OR FIRE AREAS.
  
 3) NOTE FOR CONTRACTOR, CONTRACTORS RESPONSIBILITY:
 ASBESTOS SURVEY
 RESIDENTIAL LEAD BASED PAINT HAZARD ACT OF 1992 AMENDED
 4/ 21/ 2005 FEDERAL ACT.
  
 2010 FBC-EXISTING BUILD. CODE 502.2 NEW AND REPLACEMENT
 MATERIALS. EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY
 THIS CODE, MATERIALS PERMITTED BY THE APPLICABLE CODE
 FOR NEW CONSTRUCTION SHALL BE USED. LIKE MATERIALS
 SHALL BE PERMITTED FOR REPAIRS AND ALTERATIONS,
 PROVIDED NO DANGEROUS OR UNSAFE CONDITION, AS DEFINED
 IN CHAPTER 2, IS CREATED. HAZARDOUS MATERIALS, SUCH AS
 ASBESTOS AND LEAD-BASED PAINT, SHALL NOT BE USED WHERE
 THE CODE FOR NEW CONSTRUCTION WOULD NOT PERMIT THEIR
 USE IN BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND
 LOCATION.
  
 4A) COMPLIED.
  
 4B) 2ND REQUEST. 2304.9.6 LOAD PATH. WHERE WALL FRAMING
 MEMBERS ARE NOT CONTINUOUS FROM FOUNDATION SILL TO
 ROOF, THE MEMBERS SHALL BE SECURED TO ENSURE A
 CONTINUOUS LOAD PATH. WHERE REQUIRED, SHEET METAL
 CLAMPS, TIES OR CLIPS SHALL BE FORMED OF GALVANIZED
 STEEL OR OTHER APPROVED CORROSION-RESISTANT MATERIAL
 NOT LESS THAN 0.040 INCH (1.01 MM) NOMINAL THICKNESS.
 THE UPDATED PLANS SHOW STRAPSFROM THE POST TO FLOOR
 JOIST BUT NOT TO THE ROOF CEILING JOIST.
  
 4C) COMPLIED.
  
 4D) 2ND REQUEST. BEDROOMS 2 THRU 5 WILL NEED TO
 INDICATE HOW MANY OCCUPANTS WILL BE SLEEPING IN THESE
 ROOMS TO COMPLY WITH WPB MUNI CODE SECTION 18-99 (1).
  
 5) PROVIDE THE WINDOW DOCUMENTATION THAT 24 EH MEETS
 THE EGRESS REQUIREMENTS. WINDOW RELACEMENT NOTE # 2
 INDICATES THE BEDROOM WINDOWS THAT NEED TO COMPLY WITH
 THE 2010 FBC-B 1029.2 EMERGENCY ESCAPE & RESCUE
 OPENINGS , MINIMUM SIZE FOR A 2ND FLOOR, EMERGENCY
 ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET
 CLEAR OPENING OF 5.7 SQUARE FEET (0.53 M2).
 THE PLANS INDICATE THE INSTALLATION OF A 24 PGT
 WINDGUARD WINDOW, NOTE THIS WINDOW ONLY HAS 4.57 SQ. FT
 IN THE WINDOW VENT, NOT THE REQUIRED 5.7 FT. THE CODE
 DOES ALLOW A 5% REDUCTION IN WINDOW SIZE DUE TO THE
 HEAVIER WINDOW FRAMES OR A CLEAR VENT OF 5.415 SQ. FT.
  
 6) WINDOW NOTE # 1 INDICATES THE INSTALATION OF NEW
 WINDOWS WITH A COMPABLE OPTION FOR OPERABLE SHUTTERS.
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 SUCH DRAWINGS
 AND SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE
 FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION.
  
 7) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
  
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS & MULLIONS
 (E) STORM SHUTTERS
  
 8)
 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-01-29 Cont ID  
Sent By jwitmer Date 2015-01-29 Time 14:59 Rev Time 0.00
Received By jwitmer Date 2015-01-28 Time 15:22 Sent To  
Notes
2015-01-29 09:47:05BUILDING PLAN REVIEW
 PERMIT: 15010809
 ADD: 1813 N. TAMARIND AVE.
 CONT: FIC CONSTRUCTION
 TEL: (407)744-5664
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. JAN. 29/ 2015
 ACTION: DENIED
  
 1) THE DESIGNER OF RECORD HAS NOT PROVIED A CODE
 ANALYSIS FOR THE 2ND FLOOR AS FAR AS USAGE: IS THIS
 TENANT SPACE A SINGLE DWELLING UNIT OR IS THIS UNIT A
 BOARDING HOUSE OR CONGREGATE LIVING FACILITY, THIS WILL
 AFFECT THE FUTURE REVIEWS. FOR THE PURPOSE OF THIS
 REVIEW IT WILL BE TAKEN AS A SINGLE DWELLING UNIT, WITH
 ONE TENANT (FAMILY) NOT A BOARDING HOUSE OR CONGREGATE
 LIVING FACILITY. SEE FBC-B 439.2
  
 2) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION: 107.3.5
 MINIMUM PLAN REVIWE CRITERIA FOR COMMERCIAL BUILDINGS.
 107.3.5.1 COMMERCIAL BUILDINGS:
 2.2 OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS
 SHALL BE DETERMINED.
 2.3 MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED
 (SEE TABLE 503).
 2.4 FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL
 INCLUDE THE FOLLOWING COMPONENTS: FIRE-RESISTANT
 SEPARATIONS SEE FBC-B 439.3 HORIZONTAL SEPERATION.
  
 3) NOTE FOR CONTRACTOR, CONTRACTORS RESPONSIBILITY:
 ASBESTOS SURVEY
 RESIDENTIAL LEAD BASED PAINT HAZARD ACT OF 1992 AMENDED
 4/ 21/ 2005 FEDERAL ACT.
  
 2010 FBC-EXISTING BUILD. CODE 502.2 NEW AND REPLACEMENT
 MATERIALS. EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY
 THIS CODE, MATERIALS PERMITTED BY THE APPLICABLE CODE
 FOR NEW CONSTRUCTION SHALL BE USED. LIKE MATERIALS
 SHALL BE PERMITTED FOR REPAIRS AND ALTERATIONS,
 PROVIDED NO DANGEROUS OR UNSAFE CONDITION, AS DEFINED
 IN CHAPTER 2, IS CREATED. HAZARDOUS MATERIALS, SUCH AS
 ASBESTOS AND LEAD-BASED PAINT, SHALL NOT BE USED WHERE
 THE CODE FOR NEW CONSTRUCTION WOULD NOT PERMIT THEIR
 USE IN BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND
 LOCATION.
  
 4A) THE DIMOLITION PLANS SHOW WHAT APPEARS TO BE A
 BEARING WALL BEING REMOVED AND DOUBLED 2X4 POST AT 32"
 O. C. PLEASE PROVIDE PLEASE PROVIDE HOW CODE COMPLIANCE
 FOR 2301.2 GENERAL DESIGN REQUIREMENTS (3) CONVENTIONAL
 LIGHT FRAME CONSTRUCTION WITH 2304 AND 2308 WAS
 ACHIEVED.
 2308.1.1 PORTIONS EXCEEDING LIMITATIONS OF CONVENTIONAL
 CONSTRUCTION.
 WHEN PORTIONS OF A BUILDING OF OTHERWISE CONVENTIONAL
 CONSTRUCTION EXCEED THE LIMITS OF SECTION 2308.2, THESE
 PORTIONS AND THE SUPPORTING LOAD PATH SHALL BE DESIGNED
 IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE AND
 THE PROVISIONS OF THIS CODE.
 SEE 2308.9.1 AND TABLE 2308.9.1.
  
 4B) 2304.9.6 LOAD PATH. WHERE WALL FRAMING MEMBERS ARE
 NOT CONTINUOUS FROM FOUNDATION SILL TO ROOF, THE
 MEMBERS SHALL BE SECURED TO ENSURE A CONTINUOUS LOAD
 PATH. WHERE REQUIRED, SHEET METAL CLAMPS, TIES OR CLIPS
 SHALL BE FORMED OF GALVANIZED STEEL OR OTHER APPROVED
 CORROSION-RESISTANT MATERIAL NOT LESS THAN 0.040 INCH
 (1.01 MM) NOMINAL THICKNESS.
  
 4C) 2304.9.7 FRAMING REQUIREMENTS. WOOD COLUMNS AND
 POSTS SHALL BE FRAMED TO PROVIDE FULL END BEARING.
 ALTERNATIVELY, COLUMN-AND-POST END CONNECTIONS SHALL BE
 DESIGNED TO RESIST THE FULL COMPRESSIVE LOADS,
 NEGLECTING END-BEARING CAPACITY. COLUMN-AND-POST END
 CONNECTIONS SHALL BE FASTENED TO RESIST LATERAL AND NET
 INDUCED UPLIFT FORCES.
  
 4) BEDROOMS 2 THRU 5 WILL NEED TO INDICATE HOW MANY
 OCCUPANTS WILL BE SLEEPING IN THESE ROOMS TO COMPLY
 WITH WPB MUNI CODE SECTION 18-99 (1).
  
 5) WINDOW RELACEMENT NOTE # 2 INDICATES THE BEDROOM
 WINDOWS THAT NEED TO COMPLY WITH THE 2010 FBC-B 1029.2
 EMERGENCY ESCAPE & RESCUE OPENINGS , MINIMUM SIZE FOR A
 2ND FLOOR, EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL
 HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET
 (0.53 M2).
 THE PLANS INDICATE THE INSTALLATION OF A 24 PGT
 WINDGUARD WINDOW, NOTE THIS WINDOW ONLY HAS 4.57 SQ. FT
 IN THE WINDOW VENT, NOT THE REQUIRED 5.7 FT. THE CODE
 DOES ALLOW A 5% REDUCTION IN WINDOW SIZE DUE TO THE
 HEAVIER WINDOW FRAMES OR A CLEAR VENT OF 5.415 SQ. FT.
  
 6) WINDOW NOTE # 1 INDICATES THE INSTALATION OF NEW
 WINDOWS WITH A COMPABLE OPTION FOR OPERABLE SHUTTERS.
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 SUCH DRAWINGS
 AND SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE
 FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION.
  
 7) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
  
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS & MULLIONS
 (E) STORM SHUTTERS
  
 8)
 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2015-06-09 Cont ID  
Sent By rlecky Date 2015-06-09 Time 12:27 Rev Time 0.00
Received By rlecky Date 2015-06-09 Time 12:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2015-05-12 Cont ID  
Sent By rlecky Date 2015-05-12 Time 11:46 Rev Time 0.00
Received By rlecky Date 2015-05-12 Time 11:22 Sent To  
Notes
2015-05-12 11:47:1415010809
 1813 TAMARIND AVE.
 RESIDENTIAL RENOVATION
 2ND REVIEW
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE ELECTRICAL
 REVIEW COMMENTS. SEVERAL OF THE INITIAL RESPONSES TO
 THE LAST REVIEW WERE INCOMPLETE AND REQUIRE
 CLARIFICATION OR ADDITIONAL INFORMATION.
  
 INCLUDE AN ELECTRICAL LOAD CALCULATION FOR THE SERVICE
 FEEDING THE BUILDING. MAIN DISCONNECTS ARE REQUIRED TO
 BE GROUPED IN ONE LOCATION. SHOW THE SIZE OF EACH
 SERVICE AND EACH MAIN DISCONNECT. NEC 230.2 NEC 110.20,
 230.66, 230.79, 230.71
  
 A BUILDING WHICH HAS MULTIPLE ELECTRIC SERVICES MUST
 HAVE ALL GROUNDING ELECTRODE CONDUCTORS BONDED
 TOGETHER. PROVIDE A GROUNDING AND BONDING DETAIL. NEC
 250.58
  
 PROVIDE A MAIN BONDING STRIP AT THE ELECTRIC SERVICE
 GROUND. NEC 250.94
  
 INDICATE THE FAULT CURRENT CAPACITY REQUIRED FOR THE
 ELECTRIC SERVICE AND ELECTRIC PANELS. NEC 110.9, 110.10
  
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINE
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-04-09 Cont ID  
Sent By rlecky Date 2015-04-09 Time 11:44 Rev Time 0.00
Received By rlecky Date 2015-04-09 Time 10:08 Sent To  
Notes
2015-04-09 11:45:5815010809
 1813 TAMARIND AVE.
 RESIDENTIAL RENOVATION
 2ND REVIEW
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 ELECTRICAL REVIEW COMMENTS. SEVERALOF THE INITIAL
 RESPONSES TO THE ORIGINAL REVIEW REQUIRE CLARIFICATION
 OR ADDITIONAL INFORMATION.
  
 SHOW THE COMPLETE ELECTRICAL SYSTEM INCLUDING ALL
 SERVICES TO THE BUILDING. THE ELECTRIC SERVICE
 DISCONNECT AS DEPICTED MAY NOT BE LOCATED ON THE SECOND
 FLOOR. A BUILDING OR OTHER STRUCTURE SERVED SHALL BE
 SUPPLIED BY ONLY ONE SERVICE. THIS BUILDING REQUIRES
 MAIN SERVICE DISCONNECTS FOR EACH OCCUPANCY WHICH ARE
 TO BE LOCATED OUTSIDE THE BUILDING AND AT THE POINT OF
 SERVICE. MAIN DISCONNECTS ARE REQUIRED TO BE GROUPED IN
 ONE LOCATION. NEC 230.2 NEC 110.20, 230.66, 230.79,
 230.71
  
 A BUILDING WHICH HAS MULTIPLE ELECTRIC SERVICES MUST
 HAVE ALL GROUNDING ELECTRODE CONDUCTORS BONDED
 TOGETHER. NEC 250.58
  
 A BONDING STRIP IS REQUIRED AT THE ELECTRIC SERVICE
 GROUND. NEC 250.94
  
 INDICATE THE FAULT CURRENT CAPACITY REQUIRED FOR THE
 ELECTRIC SERVICE AND ELECTRIC PANELS. NEC 110.9, 110.10
  
 PROVIDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE BUILDING HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIREPLACE, A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2010 FBC R314, 315
  
 ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL BRANCH
 CIRCUITS SUPPLYING OUTLETS. NEC 210.12
  
 PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE BATHROOMS.
 NEC 210.11 (C)(3)
  
 PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE DINING AREA
 OUTLETS. NEC 210.52(B)(1)
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-02-10 Cont ID  
Sent By rlecky Date 2015-02-10 Time 13:43 Rev Time 0.00
Received By rlecky Date 2015-02-10 Time 12:13 Sent To  
Notes
2015-02-10 13:43:3915010809
 1813 TAMARIND AVE.
 RESIDENTIAL RENOVATION
  
 THE SCOPE OF THE PROPOSED ELECTRICAL WORK IS NOT CLEAR.
 THE PROPERTY APPEARS TO HAVE MORE THAN ONE FLOOR WITH A
 COMMERCIAL USE. PLEASE REVISE THE PLANS IN RESPONSE TO
 THE FOLLOWING ELECTRICAL REVIEW COMMENTS. SHOW THE
 COMPLETE ELECTRICAL SYSTEM.
  
 A BUILDING OR OTHER STRUCTURE SERVED SHALL BE SUPPLIED
 BY ONLY ONE SERVICE. THIS BUILDING REQUIRES A MAIN
 SERVICE DISCONNECT FOR EACH OCCUPANCY AND LOCATED
 OUTSIDE AT THE POINT OF SERVICE. MAIN DISCONNECTS ARE
 REQUIRED TO BE GROUPED IN ONE LOCATION. NEC 230.2 NEC
 110.20, 230.66, 230.79, 230.71
  
 A BONDING STRIP IS REQUIRED AT THE ELECTRIC SERVICE
 GROUND NEC 250.94
  
 INDICATE THE FAULT CURRENT CAPACITY REQUIRED FOR THE
 ELECTRIC SERVICE AND ELECTRIC PANELS. NEC 110.9, 110.10
  
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE BUILDING HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIREPLACE, A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2010 FBC R314, 315
  
 NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11
  
 GFCI PROTECTED RECEPTACLES ARE REQUIRED AT THE FRONT
 ENTRANCE. NEC 210.8, 210.52(E)
  
 ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW
 GENERAL PURPOSE OUTLETS INCLUDING LIGHTING. NEC 210.12
  
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status N Date 2015-04-27 Cont ID  
Sent By pleduc Date 2015-04-27 Time   Rev Time 0.00
Received By pleduc Date 2015-04-27 Time 15:47 Sent To  
Notes
2015-04-27 16:02:47THIS PLAN WAS REVIEWED BY PETER LEDUC, FIRE MARSHAL,
 WITH THE FOLLOWING COMMENTS:
  
 AN ATTACHED LETTER INDICATES THIS IS A SINGLE FAMILY
 DWELLING AND A FIRE REVIEW IS NOT APPLICABLE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2015-03-27 Cont ID  
Sent By pleduc Date 2015-03-27 Time   Rev Time 0.00
Received By pleduc Date 2015-03-27 Time 10:45 Sent To  
Notes
2015-03-27 10:49:54THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE PROVIDE THE OCCUPANY TYPE OF THE ENTIRE BUILDING
 FOR THIS PROJECT.
  
 GREATER DETAIL IS REQUIRED FOR THE ENTIRE BUILDING AND
 ATTACHMENTS.
  
 IT APPEARS THAT THE UNIT PROPOSED IS ON THE SECOND
 FLOOR. WHAT OCCUPIES THE FIRST FLOOR AND EVERY OTHER
 SPACE ATTACHED TO THIS BUILDING?

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-01-30 Cont ID  
Sent By pleduc Date 2015-01-30 Time   Rev Time 0.00
Received By pleduc Date 2015-01-30 Time 11:05 Sent To  
Notes
2015-01-30 11:25:08THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE PROVIDE THE NUMBER OF SEPARATE UNITS OF THIS
 OCCUPANCY. FIRE PREVENTION REVIEW IS NOT REQUIRED FOR
 ONE AND TWO FAMILY DWELLINGS.
  
 FURTHER COMMENT IS WITHHELD PENDING THIS INFORMATION.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2015-09-02 Cont ID  
Sent By jwitmer Date 2015-09-02 Time 13:10 Rev Time 0.00
Received By jwitmer Date 2015-09-02 Time 13:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-07-30 Cont ID  
Sent By cpuell Date 2015-07-08 Time 10:54 Rev Time 0.00
Received By cpuell Date 2015-06-04 Time 09:52 Sent To  
Notes
2015-06-05 09:52:53RE-SUBMITTAL SENT TO B14 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-06-02 Cont ID  
Sent By shill Date 2015-05-13 Time 15:28 Rev Time 0.00
Received By shill Date 2015-04-23 Time 14:40 Sent To  
Notes
2015-04-23 14:42:28B38
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-04-23 Cont ID  
Sent By shill Date 2015-04-22 Time 14:38 Rev Time 0.00
Received By shill Date 2015-03-24 Time 08:42 Sent To  
Notes
2015-03-25 08:43:09RE-SUBMITTAL SENT TO B7 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-21 Cont ID  
Sent By hmoser Date 2015-03-21 Time 09:23 Rev Time 0.00
Received By hmoser Date 2015-01-22 Time 14:36 Sent To  
Notes
2015-01-23 14:37:53B07

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 5 Status P Date 2015-09-02 Cont ID  
Sent By jwitmer Date 2015-09-02 Time 13:08 Rev Time 0.00
Received By jwitmer Date 2015-09-02 Time 13:08 Sent To  
Notes
2015-09-02 13:10:24P. B. C. IMPACT FEE ASSESSMENT
 RECEIPT NO. 2015-0902-150
 MU-2015-017032-0000
 FEE: $1,593.23

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status F Date 2015-06-24 Cont ID  
Sent By jwitmer Date 2015-06-24 Time 07:09 Rev Time 0.00
Received By jwitmer Date 2015-06-24 Time   Sent To  
Notes
2015-06-24 07:09:39IMPACT FEES
 BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2015-04-30 Cont ID  
Sent By jwitmer Date 2015-04-30 Time 07:15 Rev Time 0.00
Received By jwitmer Date 2015-04-30 Time   Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-03-26 Cont ID  
Sent By jwitmer Date 2015-03-26 Time   Rev Time 0.00
Received By jwitmer Date 2015-03-26 Time   Sent To  
Notes
2015-03-26 06:30:42BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-01-29 Cont ID  
Sent By jwitmer Date 2015-01-29 Time 14:59 Rev Time 0.00
Received By jwitmer Date 2015-01-29 Time 14:59 Sent To  
Notes
2015-01-29 15:00:03BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2015-07-08 Cont ID  
Sent By ccole Date 2015-07-08 Time 12:50 Rev Time 0.00
Received By ccole Date 2015-07-08 Time 12:50 Sent To  
Notes
2015-06-05 09:37:08NEW DRAWINGS SUBMITTED. JG.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-05-13 Cont ID  
Sent By hmoser Date 2015-05-13 Time 13:53 Rev Time 0.00
Received By hmoser Date 2015-05-13 Time 13:22 Sent To  
Notes
2015-05-13 13:53:19PASS PROVISO
 REFER TO SECTION 601.4 BALANCED RETURN AIR
 2010 FBC (M) HM.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2015-04-22 Cont ID  
Sent By hmoser Date 2015-04-22 Time 10:08 Rev Time 0.00
Received By hmoser Date 2015-04-22 Time 09:10 Sent To  
Notes
2015-04-22 10:08:55PLAN DENIED
 1) PROVIDE GRILL SIZE ON PLAN PER 107 2010 FBC.
 2) PROVIDE FRESH AIR CALCULATIONS ON PLAN PER
 TABLE 403.3 FBC (M) 2010
 3) SHOW LOCATION OF CONDENSER ON PLAN. IF
 CONDENSER IS ON THE ROOF REFER TO SECTION
 301.12 WIND RESISTANCE 2010 FBC (M)
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-03-21 Cont ID  
Sent By hmoser Date 2015-03-21 Time 09:23 Rev Time 0.00
Received By hmoser Date 2015-03-21 Time 08:25 Sent To  
Notes
2015-03-21 09:23:37PLAN DENIED
 1) PROVIDE GRILL SIZE ON PLANS. PER 107 FBC 2010
 2) PROVIDE ENERGY CALCULATIONS PER SECTION
 503.2.1 CALCULATION OF HEATING AND COOLING
 2010 FLORIDA ENERGY CODE
 3) PROVIDE FRESH AIR CALCULATION PER TABLE 403.3
 FBC (M) 2010
 4) SHOW LOCATION OF CONDENSER ON THE PLAN.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2015-07-01 Cont ID  
Sent By tklarge Date 2015-07-01 Time 07:33 Rev Time 0.00
Received By tklarge Date 2015-07-01 Time 07:33 Sent To  
Notes
2015-06-05 09:36:10NEW DRAWINGS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 3 Status P Date 2015-05-13 Cont ID  
Sent By tklarge Date 2015-05-13 Time 10:43 Rev Time 0.00
Received By tklarge Date 2015-05-13 Time 10:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-04-19 Cont ID  
Sent By tklarge Date 2015-04-19 Time 04:32 Rev Time 0.00
Received By tklarge Date 2015-04-19 Time 04:32 Sent To  
Notes
2015-04-18 10:19:01INDICATE THE OCCUPANCY OF THIS FLOOR BASED ON SEC. 302
 OF THE 2010 FLORIDA BUILDING CODE.THE PLANS NOTE "
 SINGLE FAMILY APARTMENT." THERE IS NO SUCH OCCUPANCY
 CLASSIFICATION OF THIS TYPE IN THE FLORIDA BUILDING
 CODE. REFER TO CHAPTER 3, SECTION 310 FOR THE SPECIFIC
 TYPE OF RESIDENTIAL OCCUPANCY. THE TYPE OF OCCUPANCY
 WILL DETERMINE THE NUMBER AND TYPE OF FIXTURES REQUIRED
 BY THE PLUMBING CODE.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
2015-03-25 08:45:17NEW DRAWINGS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-01-28 Cont ID  
Sent By tklarge Date 2015-01-28 Time 06:56 Rev Time 0.00
Received By tklarge Date 2015-01-28 Time 06:46 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2015-06-08 Cont ID  
Sent By sgraham Date 2015-06-08 Time 15:40 Rev Time 0.00
Received By sgraham Date 2015-06-08 Time 15:40 Sent To  
Notes
2015-06-05 09:39:11NEW DRAWINGS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 2 Status P Date 2015-04-16 Cont ID  
Sent By sgraham Date 2015-04-16 Time 12:20 Rev Time 0.00
Received By sgraham Date 2015-04-16 Time 12:20 Sent To  
Notes
2015-03-25 08:44:45NEW DRAWINGS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 1 Status P Date 2015-02-04 Cont ID  
Sent By sgraham Date 2015-02-04 Time 11:43 Rev Time 0.00
Received By sgraham Date 2015-02-04 Time 11:43 Sent To  
Notes
2015-02-04 11:46:422/4/15 ZONING APPROVED WITH NOTICE;
  
 1. THE PRESENT USE OF THE UPSTAIR IS A NON CONFORMING
 ROOMING HOUSE. THE ROOMING HOUSE WILL NOT BE ALLOWED
 ONCE THE SPACE IS CONVERTED TO A SINGLE FAMILY USE>
2015-02-02 16:08:202/2/15