| Plan Review Stops For Permit 15010809 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-06-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-06-24 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-06-24 |
Time |
06:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-04-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-04-30 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-04-30 |
Time |
06:46 |
Sent To |
|
|
| Notes |
| 2015-04-30 07:03:23 | BUILDING PLAN REVIEW | | | PERMIT: 15010809 | | | ADD: 1813 N. TAMARIND AVE. | | | CONT: FIC CONSTRUCTION | | | TEL: (407)744-5664 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: THURS. APRIL 30/ 2015 | | | | | | NOTICE !!!!!!!!!!!!!NOTICE!!!!!!!!!!!!!!: CHAPTER | | | 553.80(2)(B) FLORIDA STATUTES STATES THAT A LOCAL | | | GOVERNMENT SHALL IMPOSE A FEE OF FOUR TIMES THE FEE FOR | | | PLAN REVIEW, IF PLANS ARE REJECTED (3) OR MORE TIMES | | | FOR REPEATED FAILURE TO CORRECT A CODE VIOLATION. | | | ------------------------------------------------------- | | | ------------------------------------------------------- | | | ------------------------------------------------------- | | | ------------------------------------------------------- | | | ---------------------------- | | | ACTION: DENIED | | | | | | 1) COMPLIED. SINGLE FAMILY DWELLING UNIT. PARTIAL | | | CHANGE OF OCCUPANCY. | | | | | | 2) COMPLIED. 5/08/2015 THE BUILDING OFFICIAL ROBERT | | | BROWN ACCEPTTED THE LETTER FROM ARCHITECT KARIN | | | MANNCHEN UNDER THE 2010 FL. EXIST. BUILDING CODE 101.5 | | | EXCEPTION FOR 1 HOUR RATING BETWEEN THE MERCANTILE AND | | | R3 RESIDENCE ABOVE. | | | | | | 3) NOTE FOR CONTRACTOR, CONTRACTORS RESPONSIBILITY: | | | ASBESTOS SURVEY | | | RESIDENTIAL LEAD BASED PAINT HAZARD ACT OF 1992 AMENDED | | | 4/ 21/ 2005 FEDERAL ACT. | | | | | | 2010 FBC-EXISTING BUILD. CODE 502.2 NEW AND REPLACEMENT | | | MATERIALS. EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY | | | THIS CODE, MATERIALS PERMITTED BY THE APPLICABLE CODE | | | FOR NEW CONSTRUCTION SHALL BE USED. LIKE MATERIALS | | | SHALL BE PERMITTED FOR REPAIRS AND ALTERATIONS, | | | PROVIDED NO DANGEROUS OR UNSAFE CONDITION, AS DEFINED | | | IN CHAPTER 2, IS CREATED. HAZARDOUS MATERIALS, SUCH AS | | | ASBESTOS AND LEAD-BASED PAINT, SHALL NOT BE USED WHERE | | | THE CODE FOR NEW CONSTRUCTION WOULD NOT PERMIT THEIR | | | USE IN BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND | | | LOCATION. | | | | | | 4A) COMPLIED. | | | | | | 4B) COMPLIED. 2304.9.6 LOAD PATH. WHERE WALL FRAMING | | | MEMBERS ARE NOT CONTINUOUS FROM FOUNDATION SILL TO | | | ROOF, THE MEMBERS SHALL BE SECURED TO ENSURE A | | | CONTINUOUS LOAD PATH. WHERE REQUIRED, SHEET METAL | | | CLAMPS, TIES OR CLIPS SHALL BE FORMED OF GALVANIZED | | | STEEL OR OTHER APPROVED CORROSION-RESISTANT MATERIAL | | | NOT LESS THAN 0.040 INCH (1.01 MM) NOMINAL THICKNESS. | | | THE UPDATED PLANS SHOW STRAPS FROM THE POST TO FLOOR | | | JOIST BUT NOT TO THE ROOF CEILING JOIST. | | | | | | 4C) COMPLIED. | | | | | | 4D) COMPLIED. | | | | | | 5) COMPLIED. | | | | | | 6) 3RD REQUEST. WINDOW NOTE # 1 INDICATES THE | | | INSTALATION OF NEW WINDOWS WITH A COMPABLE OPTION FOR | | | OPERABLE SHUTTERS, NO OPTIONS!!!! ITS A EITHER OR NO | | | OPTIONS. 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 SUCH | | | DRAWINGS AND SPECIFICATIONS SHALL CONTAIN INFORMATION, | | | IN THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. | | | | | | 7) 3RD REQUEST. 2010 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS & MULLIONS | | | (E) STORM SHUTTERS | | | | | | 8) 3RD REQUEST. 2010 FBC 107.3.4.1 PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-03-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-03-25 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-03-25 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2015-03-25 16:58:49 | BUILDING PLAN REVIEW | | | PERMIT: 15010809 | | | ADD: 1813 N. TAMARIND AVE. | | | CONT: FIC CONSTRUCTION | | | TEL: (407)744-5664 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. JAN. 29/ 2015 | | | ACTION: DENIED | | | | | | 1) COMPLIED. SINGLE FAMILY DWELLING UNIT. PARTIAL | | | CHANGE OF OCCUPANCY. | | | | | | 2) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION: 107.3.5 | | | MINIMUM PLAN REVIWE CRITERIA FOR COMMERCIAL BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 2.2 SEMI- COMPLIED. MIXED USE/ UPSTAIRS SINGLE FAMILY | | | DWELLING UNIT. DOWNSTAIRS OCCUPANCY GROUP NOT PROVIDED. | | | PROPERTY APPRAISER OFFICE STORE/ OFFICE. | | | | | | 2.3 2ND REQUEST . MINIMUM TYPE OF CONSTRUCTION SHALL BE | | | DETERMINED (SEE TABLE 503). | | | 2.4 FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL | | | INCLUDE THE FOLLOWING COMPONENTS: FIRE-RESISTANT | | | SEPARATIONS SEE FBC-B 439.3 HORIZONTAL SEPERATION. | | | 2010 EXST. BLDG. CODE 912.1.1.2 CHANGE OF OCCUPANCY | | | CLASSIFICATION WITH SEPARATION. WHERE A PORTION OF AN | | | EXISTING BUILDING THAT IS CHANGED TO A NEW OCCUPANCY | | | CLASSIFICATION AND THAT PORTION IS SEPARATED FROM THE | | | REMAINDER OF THE BUILDING WITH FIRE BARRIERS HAVING A | | | FIRE-RESISTANCE RATING AS REQUIRED IN THE FLORIDA | | | BUILDING CODE, BUILDING FOR THE SEPARATE OCCUPANCY, | | | THAT PORTION SHALL COMPLY WITH ALL THE REQUIREMENTS OF | | | CHAPTER 8 FOR THE NEW OCCUPANCY CLASSIFICATION AND WITH | | | THE REQUIREMENTS OF THIS CHAPTER. | | | FBC-B 707.3.9 & TABLE 707.3.9. REQUIRES 2 HOUR FLOOR | | | CEILING ASSEMBLY, HORIZONTAL ASSEMBLIES OR FIRE AREAS. | | | | | | 3) NOTE FOR CONTRACTOR, CONTRACTORS RESPONSIBILITY: | | | ASBESTOS SURVEY | | | RESIDENTIAL LEAD BASED PAINT HAZARD ACT OF 1992 AMENDED | | | 4/ 21/ 2005 FEDERAL ACT. | | | | | | 2010 FBC-EXISTING BUILD. CODE 502.2 NEW AND REPLACEMENT | | | MATERIALS. EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY | | | THIS CODE, MATERIALS PERMITTED BY THE APPLICABLE CODE | | | FOR NEW CONSTRUCTION SHALL BE USED. LIKE MATERIALS | | | SHALL BE PERMITTED FOR REPAIRS AND ALTERATIONS, | | | PROVIDED NO DANGEROUS OR UNSAFE CONDITION, AS DEFINED | | | IN CHAPTER 2, IS CREATED. HAZARDOUS MATERIALS, SUCH AS | | | ASBESTOS AND LEAD-BASED PAINT, SHALL NOT BE USED WHERE | | | THE CODE FOR NEW CONSTRUCTION WOULD NOT PERMIT THEIR | | | USE IN BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND | | | LOCATION. | | | | | | 4A) COMPLIED. | | | | | | 4B) 2ND REQUEST. 2304.9.6 LOAD PATH. WHERE WALL FRAMING | | | MEMBERS ARE NOT CONTINUOUS FROM FOUNDATION SILL TO | | | ROOF, THE MEMBERS SHALL BE SECURED TO ENSURE A | | | CONTINUOUS LOAD PATH. WHERE REQUIRED, SHEET METAL | | | CLAMPS, TIES OR CLIPS SHALL BE FORMED OF GALVANIZED | | | STEEL OR OTHER APPROVED CORROSION-RESISTANT MATERIAL | | | NOT LESS THAN 0.040 INCH (1.01 MM) NOMINAL THICKNESS. | | | THE UPDATED PLANS SHOW STRAPSFROM THE POST TO FLOOR | | | JOIST BUT NOT TO THE ROOF CEILING JOIST. | | | | | | 4C) COMPLIED. | | | | | | 4D) 2ND REQUEST. BEDROOMS 2 THRU 5 WILL NEED TO | | | INDICATE HOW MANY OCCUPANTS WILL BE SLEEPING IN THESE | | | ROOMS TO COMPLY WITH WPB MUNI CODE SECTION 18-99 (1). | | | | | | 5) PROVIDE THE WINDOW DOCUMENTATION THAT 24 EH MEETS | | | THE EGRESS REQUIREMENTS. WINDOW RELACEMENT NOTE # 2 | | | INDICATES THE BEDROOM WINDOWS THAT NEED TO COMPLY WITH | | | THE 2010 FBC-B 1029.2 EMERGENCY ESCAPE & RESCUE | | | OPENINGS , MINIMUM SIZE FOR A 2ND FLOOR, EMERGENCY | | | ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET | | | CLEAR OPENING OF 5.7 SQUARE FEET (0.53 M2). | | | THE PLANS INDICATE THE INSTALLATION OF A 24 PGT | | | WINDGUARD WINDOW, NOTE THIS WINDOW ONLY HAS 4.57 SQ. FT | | | IN THE WINDOW VENT, NOT THE REQUIRED 5.7 FT. THE CODE | | | DOES ALLOW A 5% REDUCTION IN WINDOW SIZE DUE TO THE | | | HEAVIER WINDOW FRAMES OR A CLEAR VENT OF 5.415 SQ. FT. | | | | | | 6) WINDOW NOTE # 1 INDICATES THE INSTALATION OF NEW | | | WINDOWS WITH A COMPABLE OPTION FOR OPERABLE SHUTTERS. | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 SUCH DRAWINGS | | | AND SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE | | | FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. | | | | | | 7) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS & MULLIONS | | | (E) STORM SHUTTERS | | | | | | 8) | | | 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-01-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-01-29 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-01-28 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2015-01-29 09:47:05 | BUILDING PLAN REVIEW | | | PERMIT: 15010809 | | | ADD: 1813 N. TAMARIND AVE. | | | CONT: FIC CONSTRUCTION | | | TEL: (407)744-5664 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. JAN. 29/ 2015 | | | ACTION: DENIED | | | | | | 1) THE DESIGNER OF RECORD HAS NOT PROVIED A CODE | | | ANALYSIS FOR THE 2ND FLOOR AS FAR AS USAGE: IS THIS | | | TENANT SPACE A SINGLE DWELLING UNIT OR IS THIS UNIT A | | | BOARDING HOUSE OR CONGREGATE LIVING FACILITY, THIS WILL | | | AFFECT THE FUTURE REVIEWS. FOR THE PURPOSE OF THIS | | | REVIEW IT WILL BE TAKEN AS A SINGLE DWELLING UNIT, WITH | | | ONE TENANT (FAMILY) NOT A BOARDING HOUSE OR CONGREGATE | | | LIVING FACILITY. SEE FBC-B 439.2 | | | | | | 2) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION: 107.3.5 | | | MINIMUM PLAN REVIWE CRITERIA FOR COMMERCIAL BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 2.2 OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS | | | SHALL BE DETERMINED. | | | 2.3 MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED | | | (SEE TABLE 503). | | | 2.4 FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL | | | INCLUDE THE FOLLOWING COMPONENTS: FIRE-RESISTANT | | | SEPARATIONS SEE FBC-B 439.3 HORIZONTAL SEPERATION. | | | | | | 3) NOTE FOR CONTRACTOR, CONTRACTORS RESPONSIBILITY: | | | ASBESTOS SURVEY | | | RESIDENTIAL LEAD BASED PAINT HAZARD ACT OF 1992 AMENDED | | | 4/ 21/ 2005 FEDERAL ACT. | | | | | | 2010 FBC-EXISTING BUILD. CODE 502.2 NEW AND REPLACEMENT | | | MATERIALS. EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY | | | THIS CODE, MATERIALS PERMITTED BY THE APPLICABLE CODE | | | FOR NEW CONSTRUCTION SHALL BE USED. LIKE MATERIALS | | | SHALL BE PERMITTED FOR REPAIRS AND ALTERATIONS, | | | PROVIDED NO DANGEROUS OR UNSAFE CONDITION, AS DEFINED | | | IN CHAPTER 2, IS CREATED. HAZARDOUS MATERIALS, SUCH AS | | | ASBESTOS AND LEAD-BASED PAINT, SHALL NOT BE USED WHERE | | | THE CODE FOR NEW CONSTRUCTION WOULD NOT PERMIT THEIR | | | USE IN BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND | | | LOCATION. | | | | | | 4A) THE DIMOLITION PLANS SHOW WHAT APPEARS TO BE A | | | BEARING WALL BEING REMOVED AND DOUBLED 2X4 POST AT 32" | | | O. C. PLEASE PROVIDE PLEASE PROVIDE HOW CODE COMPLIANCE | | | FOR 2301.2 GENERAL DESIGN REQUIREMENTS (3) CONVENTIONAL | | | LIGHT FRAME CONSTRUCTION WITH 2304 AND 2308 WAS | | | ACHIEVED. | | | 2308.1.1 PORTIONS EXCEEDING LIMITATIONS OF CONVENTIONAL | | | CONSTRUCTION. | | | WHEN PORTIONS OF A BUILDING OF OTHERWISE CONVENTIONAL | | | CONSTRUCTION EXCEED THE LIMITS OF SECTION 2308.2, THESE | | | PORTIONS AND THE SUPPORTING LOAD PATH SHALL BE DESIGNED | | | IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE AND | | | THE PROVISIONS OF THIS CODE. | | | SEE 2308.9.1 AND TABLE 2308.9.1. | | | | | | 4B) 2304.9.6 LOAD PATH. WHERE WALL FRAMING MEMBERS ARE | | | NOT CONTINUOUS FROM FOUNDATION SILL TO ROOF, THE | | | MEMBERS SHALL BE SECURED TO ENSURE A CONTINUOUS LOAD | | | PATH. WHERE REQUIRED, SHEET METAL CLAMPS, TIES OR CLIPS | | | SHALL BE FORMED OF GALVANIZED STEEL OR OTHER APPROVED | | | CORROSION-RESISTANT MATERIAL NOT LESS THAN 0.040 INCH | | | (1.01 MM) NOMINAL THICKNESS. | | | | | | 4C) 2304.9.7 FRAMING REQUIREMENTS. WOOD COLUMNS AND | | | POSTS SHALL BE FRAMED TO PROVIDE FULL END BEARING. | | | ALTERNATIVELY, COLUMN-AND-POST END CONNECTIONS SHALL BE | | | DESIGNED TO RESIST THE FULL COMPRESSIVE LOADS, | | | NEGLECTING END-BEARING CAPACITY. COLUMN-AND-POST END | | | CONNECTIONS SHALL BE FASTENED TO RESIST LATERAL AND NET | | | INDUCED UPLIFT FORCES. | | | | | | 4) BEDROOMS 2 THRU 5 WILL NEED TO INDICATE HOW MANY | | | OCCUPANTS WILL BE SLEEPING IN THESE ROOMS TO COMPLY | | | WITH WPB MUNI CODE SECTION 18-99 (1). | | | | | | 5) WINDOW RELACEMENT NOTE # 2 INDICATES THE BEDROOM | | | WINDOWS THAT NEED TO COMPLY WITH THE 2010 FBC-B 1029.2 | | | EMERGENCY ESCAPE & RESCUE OPENINGS , MINIMUM SIZE FOR A | | | 2ND FLOOR, EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL | | | HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET | | | (0.53 M2). | | | THE PLANS INDICATE THE INSTALLATION OF A 24 PGT | | | WINDGUARD WINDOW, NOTE THIS WINDOW ONLY HAS 4.57 SQ. FT | | | IN THE WINDOW VENT, NOT THE REQUIRED 5.7 FT. THE CODE | | | DOES ALLOW A 5% REDUCTION IN WINDOW SIZE DUE TO THE | | | HEAVIER WINDOW FRAMES OR A CLEAR VENT OF 5.415 SQ. FT. | | | | | | 6) WINDOW NOTE # 1 INDICATES THE INSTALATION OF NEW | | | WINDOWS WITH A COMPABLE OPTION FOR OPERABLE SHUTTERS. | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 SUCH DRAWINGS | | | AND SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE | | | FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. | | | | | | 7) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS & MULLIONS | | | (E) STORM SHUTTERS | | | | | | 8) | | | 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2015-06-09 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2015-06-09 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2015-06-09 |
Time |
12:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2015-05-12 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2015-05-12 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2015-05-12 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2015-05-12 11:47:14 | 15010809 | | | 1813 TAMARIND AVE. | | | RESIDENTIAL RENOVATION | | | 2ND REVIEW | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE ELECTRICAL | | | REVIEW COMMENTS. SEVERAL OF THE INITIAL RESPONSES TO | | | THE LAST REVIEW WERE INCOMPLETE AND REQUIRE | | | CLARIFICATION OR ADDITIONAL INFORMATION. | | | | | | INCLUDE AN ELECTRICAL LOAD CALCULATION FOR THE SERVICE | | | FEEDING THE BUILDING. MAIN DISCONNECTS ARE REQUIRED TO | | | BE GROUPED IN ONE LOCATION. SHOW THE SIZE OF EACH | | | SERVICE AND EACH MAIN DISCONNECT. NEC 230.2 NEC 110.20, | | | 230.66, 230.79, 230.71 | | | | | | A BUILDING WHICH HAS MULTIPLE ELECTRIC SERVICES MUST | | | HAVE ALL GROUNDING ELECTRODE CONDUCTORS BONDED | | | TOGETHER. PROVIDE A GROUNDING AND BONDING DETAIL. NEC | | | 250.58 | | | | | | PROVIDE A MAIN BONDING STRIP AT THE ELECTRIC SERVICE | | | GROUND. NEC 250.94 | | | | | | INDICATE THE FAULT CURRENT CAPACITY REQUIRED FOR THE | | | ELECTRIC SERVICE AND ELECTRIC PANELS. NEC 110.9, 110.10 | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINE | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-04-09 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2015-04-09 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2015-04-09 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2015-04-09 11:45:58 | 15010809 | | | 1813 TAMARIND AVE. | | | RESIDENTIAL RENOVATION | | | 2ND REVIEW | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | ELECTRICAL REVIEW COMMENTS. SEVERALOF THE INITIAL | | | RESPONSES TO THE ORIGINAL REVIEW REQUIRE CLARIFICATION | | | OR ADDITIONAL INFORMATION. | | | | | | SHOW THE COMPLETE ELECTRICAL SYSTEM INCLUDING ALL | | | SERVICES TO THE BUILDING. THE ELECTRIC SERVICE | | | DISCONNECT AS DEPICTED MAY NOT BE LOCATED ON THE SECOND | | | FLOOR. A BUILDING OR OTHER STRUCTURE SERVED SHALL BE | | | SUPPLIED BY ONLY ONE SERVICE. THIS BUILDING REQUIRES | | | MAIN SERVICE DISCONNECTS FOR EACH OCCUPANCY WHICH ARE | | | TO BE LOCATED OUTSIDE THE BUILDING AND AT THE POINT OF | | | SERVICE. MAIN DISCONNECTS ARE REQUIRED TO BE GROUPED IN | | | ONE LOCATION. NEC 230.2 NEC 110.20, 230.66, 230.79, | | | 230.71 | | | | | | A BUILDING WHICH HAS MULTIPLE ELECTRIC SERVICES MUST | | | HAVE ALL GROUNDING ELECTRODE CONDUCTORS BONDED | | | TOGETHER. NEC 250.58 | | | | | | A BONDING STRIP IS REQUIRED AT THE ELECTRIC SERVICE | | | GROUND. NEC 250.94 | | | | | | INDICATE THE FAULT CURRENT CAPACITY REQUIRED FOR THE | | | ELECTRIC SERVICE AND ELECTRIC PANELS. NEC 110.9, 110.10 | | | | | | PROVIDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND | | | OUTSIDE EACH SLEEPING AREA. IF THE BUILDING HAS GAS | | | APPLIANCES, AN ATTACHED GARAGE OR A FIREPLACE, A CARBON | | | MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH | | | ROOM USED FOR SLEEPING. 2010 FBC R314, 315 | | | | | | ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL BRANCH | | | CIRCUITS SUPPLYING OUTLETS. NEC 210.12 | | | | | | PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE BATHROOMS. | | | NEC 210.11 (C)(3) | | | | | | PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE DINING AREA | | | OUTLETS. NEC 210.52(B)(1) | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-02-10 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2015-02-10 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2015-02-10 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2015-02-10 13:43:39 | 15010809 | | | 1813 TAMARIND AVE. | | | RESIDENTIAL RENOVATION | | | | | | THE SCOPE OF THE PROPOSED ELECTRICAL WORK IS NOT CLEAR. | | | THE PROPERTY APPEARS TO HAVE MORE THAN ONE FLOOR WITH A | | | COMMERCIAL USE. PLEASE REVISE THE PLANS IN RESPONSE TO | | | THE FOLLOWING ELECTRICAL REVIEW COMMENTS. SHOW THE | | | COMPLETE ELECTRICAL SYSTEM. | | | | | | A BUILDING OR OTHER STRUCTURE SERVED SHALL BE SUPPLIED | | | BY ONLY ONE SERVICE. THIS BUILDING REQUIRES A MAIN | | | SERVICE DISCONNECT FOR EACH OCCUPANCY AND LOCATED | | | OUTSIDE AT THE POINT OF SERVICE. MAIN DISCONNECTS ARE | | | REQUIRED TO BE GROUPED IN ONE LOCATION. NEC 230.2 NEC | | | 110.20, 230.66, 230.79, 230.71 | | | | | | A BONDING STRIP IS REQUIRED AT THE ELECTRIC SERVICE | | | GROUND NEC 250.94 | | | | | | INDICATE THE FAULT CURRENT CAPACITY REQUIRED FOR THE | | | ELECTRIC SERVICE AND ELECTRIC PANELS. NEC 110.9, 110.10 | | | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND | | | OUTSIDE EACH SLEEPING AREA. IF THE BUILDING HAS GAS | | | APPLIANCES, AN ATTACHED GARAGE OR A FIREPLACE, A CARBON | | | MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH | | | ROOM USED FOR SLEEPING. 2010 FBC R314, 315 | | | | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | | | | GFCI PROTECTED RECEPTACLES ARE REQUIRED AT THE FRONT | | | ENTRANCE. NEC 210.8, 210.52(E) | | | | | | ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW | | | GENERAL PURPOSE OUTLETS INCLUDING LIGHTING. NEC 210.12 | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
N |
Date |
2015-04-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-04-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-04-27 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2015-04-27 16:02:47 | THIS PLAN WAS REVIEWED BY PETER LEDUC, FIRE MARSHAL, | | | WITH THE FOLLOWING COMMENTS: | | | | | | AN ATTACHED LETTER INDICATES THIS IS A SINGLE FAMILY | | | DWELLING AND A FIRE REVIEW IS NOT APPLICABLE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2015-03-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-03-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-03-27 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2015-03-27 10:49:54 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE PROVIDE THE OCCUPANY TYPE OF THE ENTIRE BUILDING | | | FOR THIS PROJECT. | | | | | | GREATER DETAIL IS REQUIRED FOR THE ENTIRE BUILDING AND | | | ATTACHMENTS. | | | | | | IT APPEARS THAT THE UNIT PROPOSED IS ON THE SECOND | | | FLOOR. WHAT OCCUPIES THE FIRST FLOOR AND EVERY OTHER | | | SPACE ATTACHED TO THIS BUILDING? |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-01-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-01-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-01-30 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2015-01-30 11:25:08 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE PROVIDE THE NUMBER OF SEPARATE UNITS OF THIS | | | OCCUPANCY. FIRE PREVENTION REVIEW IS NOT REQUIRED FOR | | | ONE AND TWO FAMILY DWELLINGS. | | | | | | FURTHER COMMENT IS WITHHELD PENDING THIS INFORMATION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2015-09-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-09-02 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-09-02 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-07-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2015-07-08 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-06-04 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2015-06-05 09:52:53 | RE-SUBMITTAL SENT TO B14 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-06-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-05-13 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-04-23 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-04-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-04-22 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-03-24 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2015-03-25 08:43:09 | RE-SUBMITTAL SENT TO B7 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-03-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-03-21 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-01-22 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
5 |
Status |
P |
Date |
2015-09-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-09-02 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-09-02 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2015-09-02 13:10:24 | P. B. C. IMPACT FEE ASSESSMENT | | | RECEIPT NO. 2015-0902-150 | | | MU-2015-017032-0000 | | | FEE: $1,593.23 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2015-06-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-06-24 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-06-24 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-06-24 07:09:39 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2015-04-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-04-30 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-04-30 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-03-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-03-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-03-26 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-03-26 06:30:42 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-01-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-01-29 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-01-29 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2015-01-29 15:00:03 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2015-07-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-07-08 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-07-08 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2015-06-05 09:37:08 | NEW DRAWINGS SUBMITTED. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-05-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-05-13 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-05-13 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2015-05-13 13:53:19 | PASS PROVISO | | | REFER TO SECTION 601.4 BALANCED RETURN AIR | | | 2010 FBC (M) HM. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-04-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-04-22 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-04-22 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2015-04-22 10:08:55 | PLAN DENIED | | | 1) PROVIDE GRILL SIZE ON PLAN PER 107 2010 FBC. | | | 2) PROVIDE FRESH AIR CALCULATIONS ON PLAN PER | | | TABLE 403.3 FBC (M) 2010 | | | 3) SHOW LOCATION OF CONDENSER ON PLAN. IF | | | CONDENSER IS ON THE ROOF REFER TO SECTION | | | 301.12 WIND RESISTANCE 2010 FBC (M) | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-03-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-03-21 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-03-21 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2015-03-21 09:23:37 | PLAN DENIED | | | 1) PROVIDE GRILL SIZE ON PLANS. PER 107 FBC 2010 | | | 2) PROVIDE ENERGY CALCULATIONS PER SECTION | | | 503.2.1 CALCULATION OF HEATING AND COOLING | | | 2010 FLORIDA ENERGY CODE | | | 3) PROVIDE FRESH AIR CALCULATION PER TABLE 403.3 | | | FBC (M) 2010 | | | 4) SHOW LOCATION OF CONDENSER ON THE PLAN. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2015-07-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-07-01 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-07-01 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2015-06-05 09:36:10 | NEW DRAWINGS SUBMITTED. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-05-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-05-13 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-05-13 |
Time |
10:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2015-04-19 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-04-19 |
Time |
04:32 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-04-19 |
Time |
04:32 |
Sent To |
|
|
| Notes |
| 2015-04-18 10:19:01 | INDICATE THE OCCUPANCY OF THIS FLOOR BASED ON SEC. 302 | | | OF THE 2010 FLORIDA BUILDING CODE.THE PLANS NOTE " | | | SINGLE FAMILY APARTMENT." THERE IS NO SUCH OCCUPANCY | | | CLASSIFICATION OF THIS TYPE IN THE FLORIDA BUILDING | | | CODE. REFER TO CHAPTER 3, SECTION 310 FOR THE SPECIFIC | | | TYPE OF RESIDENTIAL OCCUPANCY. THE TYPE OF OCCUPANCY | | | WILL DETERMINE THE NUMBER AND TYPE OF FIXTURES REQUIRED | | | BY THE PLUMBING CODE. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | 2015-03-25 08:45:17 | NEW DRAWINGS SUBMITTED. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-01-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-28 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-28 |
Time |
06:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-06-08 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-06-08 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-06-08 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2015-06-05 09:39:11 | NEW DRAWINGS SUBMITTED. JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-04-16 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-04-16 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-04-16 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2015-03-25 08:44:45 | NEW DRAWINGS SUBMITTED. JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-02-04 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-02-04 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2015-02-04 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2015-02-04 11:46:42 | 2/4/15 ZONING APPROVED WITH NOTICE; | | | | | | 1. THE PRESENT USE OF THE UPSTAIR IS A NON CONFORMING | | | ROOMING HOUSE. THE ROOMING HOUSE WILL NOT BE ALLOWED | | | ONCE THE SPACE IS CONVERTED TO A SINGLE FAMILY USE> | | 2015-02-02 16:08:20 | 2/2/15 |
|
|