Plan Review Details - Permit 15010618
| Plan Review Stops For Permit 15010618 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-01-29 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-29 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-29 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2015-01-29 09:58:01 | VERIFY COMPLIANCE WITH THE FOLLOWING: | | | | | | 1) NEC 210.4 MULTIWIRE BRANCH CIRCUITS. (A) GENERAL. | | | BRANCH CIRCUITS RECOGNIZED BY THIS ARTICLE SHALL BE | | | PERMITTED AS MULTIWIRE CIRCUITS. A MULTIWIRE CIRCUIT | | | SHALL BE PERMITTED TO BE CONSIDERED AS MULTIPLE | | | CIRCUITS. ALL CONDUCTORS OF A MULTIWIRE BRANCH CIRCUIT | | | SHALL ORIGINATE FROM THE SAME PANELBOARD OR SIMILAR | | | DISTRIBUTION EQUIPMENT. | | | | | | 2) NEC 210.7 BRANCH-CIRCUIT REQUIREMENTS FOR DEVICE | | | CONNECTIONS AND LOCATIONS. | | | (A) RECEPTACLE OUTLET LOCATION. RECEPTACLE OUTLETS | | | SHALL BE LOCATED IN BRANCH CIRCUITS IN ACCORDANCE WITH | | | PART III OF ARTICLE 210. | | | (B) MULTIPLE BRANCH CIRCUITS. WHERE TWO OR MORE BRANCH | | | CIRCUITS SUPPLY DEVICES OR EQUIPMENT ON THE SAME YOKE, | | | A MEANS TO SIMULTANEOUSLY DISCONNECT THE UNGROUNDED | | | CONDUCTORS | | | | | | 3) NEC 300.13 MECHANICAL AND ELECTRICAL CONTINUITY ? | | | CONDUCTORS. (B) DEVICE REMOVAL. IN MULTIWIRE BRANCH | | | CIRCUITS, THE CONTINUITY OF A GROUNDED CONDUCTOR SHALL | | | NOT DEPEND ON DEVICE CONNECTIONS SUCH AS LAMPHOLDERS, | | | RECEPTACLES, AND SO FORTH, WHERE THE REMOVAL OF SUCH | | | DEVICES WOULD INTERRUPT THE CONTINUITY. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-01-22 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-22 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-22 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2015-01-22 09:40:34 | REVISE PLANS FOR CLARIFICATION IN RESPONSE TO THE | | | FOLLOWING: | | | | | | 1) PROVIDE PANEL NAMES ON SITE PLAN CORRESPONDING TO | | | THE PANEL NAMES ON THE RISER. | | | 2) PROVIDE CIRCUIT NUMBERS ON SITE PLAN CORRESPONDING | | | TO PANEL SCHEDULES. | | | 3) PROVIDE WIRE SIZES ON SITE PLAN CORRESPONDING TO | | | CIRCUIT NUMBERS ON PANEL SCHEDULES. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-01-29 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-29 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-28 |
Time |
18:47 |
Sent To |
|
|
| Notes |
| 2015-01-28 18:48:46 | TO DAH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-01-22 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-22 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-20 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
|