Plan Review Details - Permit 15010581
Plan Review Stops For Permit 15010581
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-03-12 Cont ID  
Sent By jwitmer Date 2015-03-12 Time 07:01 Rev Time 0.00
Received By jwitmer Date 2015-03-12 Time 06:30 Sent To  
Notes
2015-02-25 17:26:43NEW DRAWINGS SUBMITTED. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2015-01-27 Cont ID  
Sent By tklarge Date 2015-01-27 Time 16:57 Rev Time  
Received By jwitmer Date 2015-01-27 Time 16:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-03-31 Cont ID  
Sent By dhayes Date 2015-03-31 Time 11:41 Rev Time 0.00
Received By dhayes Date 2015-03-31 Time 11:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-01-20 Cont ID  
Sent By dhayes Date 2015-01-20 Time 12:53 Rev Time 0.00
Received By dhayes Date 2015-01-20 Time 12:53 Sent To  
Notes
2015-01-20 13:36:571/20/2015
 PROJECT: BOA ADA COMPLIANCE
 PERMIT#: 15010581
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) A SEPARATE ELECTRICAL PERMIT APPLICATION IS REQUIRED
 FOR THE ELECTRICAL SCOPE OF THIS PROJECT..
  
 2) PROVIDE ELECTRICAL PLANS AND SPECIFICATIONS TO
 INDICATE COMPLIANCE WITH THE FBC-ENERGY 505.2 AND THE
 NEC 422.52 FOR THE GFCI PROTECTED RECEPTACLE OUTLET AT
 THE DRINKING FOUNTAIN.
  
 3) PROVIDE A LIGHTING FIXTURE PLAN INDICATING AND NEW
 FIXTURES, RELOCATED FIXTURES AND ASSOCIATED SWITCHES OR
 LIGHTING CONTROLS, AND EXISTING FIXTURES TO REMAIN. WPB
 AMENDMENTS TO FBC 107.3
  
 4) INCLUDE EMERGENCY AND EXIT LIGHTING ON THE ELECRICAL
 LIGHTING PLAN TO INDICATE COMPLIANCE WITH NEC 700.12(F)
 AND 700.16.
  
 5) NOTES ON SHEET A00.00 CALL FOR WORK TO COMPLY WITH
 GOVERNING CODES, THEN CALLS OUT THE 2011 EDITION OF THE
 NATIONAL ELECTRICAL CODE. THE 2008 EDITION IS CURENTLY
 IN EFFECT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2015-04-09 Cont ID  
Sent By cranford Date 2015-04-09 Time 15:09 Rev Time 0.00
Received By cranford Date 2015-04-09 Time 14:12 Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2015-03-05 Cont ID  
Sent By   Date 2015-03-05 Time   Rev Time 0.00
Received By cranford Date 2015-03-05 Time 14:55 Sent To  
Notes
2015-03-05 15:07:55ENGINEERING DEPT COMMENTS
  
 PLEASE REVISE THE PARKING STALLS TO COMPLY WITH SECTION
 94-443, FIGURE XIV-2 AND SECTION 94-485. THE PARKING
 STALLS MUST EITHER HAVE WHEEL STOPS OR ABUT A SIDEWALK
 WITH A MINIMUM WIDTH OF SEVEN FEET.
  
 PLEASE REVISE THE PLANS TO INCLUDE SEDIMENT CONTROL AT
 CATCH BASIN DURING CONSTRUCTION.
  
 KELLY CRANFORD, PE
 CITY LAND DEVELOPMENT ENGINEER
 [email protected]
 561-494-1098 (OFFICE)
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-03-05 Cont ID  
Sent By pleduc Date 2015-03-05 Time   Rev Time 0.00
Received By pleduc Date 2015-03-05 Time 12:05 Sent To  
Notes
2015-02-25 17:27:39NEW DRAWINGS SUBMITTED. JG.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-01-23 Cont ID  
Sent By pleduc Date 2015-01-23 Time   Rev Time 0.00
Received By pleduc Date 2015-01-23 Time 11:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-04-11 Cont ID  
Sent By tklarge Date 2015-04-11 Time 09:07 Rev Time 0.00
Received By tklarge Date 2015-04-10 Time   Sent To  
Notes
2015-04-10 18:27:24SENT TO T LARGE

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2015-04-09 Time   Rev Time 0.00
Received By jgomez Date 2015-04-07 Time 15:17 Sent To  
Notes
2015-04-07 15:17:53RE-SUBMITTAL SENT TO TIM LARGE FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-03-31 Cont ID  
Sent By dhayes Date 2015-03-31 Time 11:42 Rev Time 0.00
Received By dhayes Date 2015-02-24 Time 17:25 Sent To  
Notes
2015-02-25 17:26:17RE-SUBMITTAL SENT TO C3 BIN FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-01-27 Cont ID  
Sent By   Date 2015-01-27 Time 16:59 Rev Time 0.00
Received By dhayes Date 2015-01-20 Time 13:40 Sent To  
Notes
2015-01-20 12:52:53B11

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-03-23 Cont ID  
Sent By hmoser Date 2015-03-23 Time 14:05 Rev Time 0.00
Received By hmoser Date 2015-03-23 Time 13:27 Sent To  
Notes
2015-03-23 14:04:57PLAN PASS
 HOOD REQUIRES SEPARATE APPLICATION PLAN AND PERMIT
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  
2015-02-25 17:27:17NEW DRAWINGS SUBMITTED. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2015-01-27 Cont ID  
Sent By jwitmer Date 2015-01-27 Time 16:57 Rev Time 0.00
Received By jwitmer Date 2015-01-27 Time 16:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2015-04-11 Cont ID  
Sent By tklarge Date 2015-04-11 Time 09:06 Rev Time 0.00
Received By tklarge Date 2015-04-11 Time 08:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2015-04-09 Cont ID  
Sent By tklarge Date 2015-04-09 Time 08:01 Rev Time 0.00
Received By tklarge Date 2015-04-09 Time 08:01 Sent To ENG
Notes
2015-04-09 08:39:03SHEET P00.01 IS MISSING FROM ONE SET OF PLANS.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-03-14 Cont ID  
Sent By tklarge Date 2015-03-14 Time 06:32 Rev Time 0.00
Received By tklarge Date 2015-03-14 Time 05:52 Sent To  
Notes
2015-03-14 06:19:371) INSERT ALL NEW SHEETS INTO THE PERMIT SET. THE
 SHEETS ARE SLIPPED IN BETWEEN THE PAGES AND COME LOOSE
 DURING THE REVIEW PROCESS.
 2) SUBMIT A SANITARY AND WATER RISER FOR ALL CHANGES TO
 THE SANITARY AND WATER PIPING SYSTEMS. WPB AMEND. TO
 2010 FBC SEC.107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-01-25 Cont ID  
Sent By tklarge Date 2015-01-25 Time 08:41 Rev Time 0.00
Received By tklarge Date 2015-01-25 Time 08:31 Sent To  
Notes
2015-01-25 08:40:511) THIS BUILDING SHOULD HAVE HAD SEPARATE SANITARY
 FACILITIES FOR MALES AND FEMALES AND THERE ARE NO
 SEPARATE FACILITIES SHOWN ON THE EXISTING PLANS. IF
 THIS TOILET ROOM WAS PREVIOUSLY THE MALE TOILET ROOM,
 MAKING THIS AN ADA COMPLIANT TOILET ROOM CREATES A
 VIOLATION OF THE PLUMBING CODE SEC.403.1.1 AND TABLE
 403.1. CLARIFY.
  

Review Stop Z ZONING
Rev No 1 Status P Date 2015-01-23 Cont ID  
Sent By ajones Date 2015-01-23 Time 11:23 Rev Time 0.00
Received By ajones Date 2015-01-23 Time 11:23 Sent To  
Notes
***NONE***