Plan Review Details - Permit 15010568
| Plan Review Stops For Permit 15010568 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-02-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-02-25 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-02-25 |
Time |
17:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-02-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-02-17 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-02-17 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2015-02-17 07:40:41 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2010 | | | | | | FROM PREVIOUS LISTS: | | | | | | CONTRACTOR CHANGED PRODUCTS (FROM "70-180 QUIET | | | CUSHION" TO "QUIET WALK"). NO TEST REPORTS PROVIDED, | | | ONLY SPEC SHEETS. PLEASE PROVIDE THE FOLLOWING TEST | | | REPORTS: | | | | | | 1. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | IF A SUSPENDED CEILING WAS USED AS A PART OF THE TEST, | | | PROVIDE INFORMATION AS TO HOW IT HAS BEEN DETERMINED | | | THAT THIS CONDITION CURRENTLY EXISTS AND HOW IT CAN BE | | | GUARANTEED THAT THE CONDITIONS IN THE UNIT BELOW WILL | | | NOT BE ALTERED. | | | | | | 2. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. IF A SUSPENDED CEILING WAS USED AS A PART | | | OF THE TEST, PROVIDE INFORMATION AS TO HOW IT HAS BEEN | | | DETERMINED THAT THIS CONDITION CURRENTLY EXISTS AND HOW | | | IT CAN BE GUARANTEED THAT THE CONDITIONS IN THE UNIT | | | BELOW WILL NOT BE ALTERED. | | | | | | 3. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM | | | E 84 OR UL 723. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-01-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-01-30 |
Time |
18:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-01-30 |
Time |
18:08 |
Sent To |
|
|
| Notes |
| 2015-01-30 18:10:15 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2010 | | | | | | FROM PREVIOUS LIST: | | | | | | 1. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | IF A SUSPENDED CEILING WAS USED AS A PART OF THE TEST, | | | PROVIDE INFORMATION AS TO HOW IT HAS BEEN DETERMINED | | | THAT THIS CONDITION CURRENTLY EXISTS AND HOW IT CAN BE | | | GUARANTEED THAT THE CONDITIONS IN THE UNIT BELOW WILL | | | NOT BE ALTERED. | | | | | | 2ND REVIEW, THE TEST REPORT PROVIDED HAS A SUSPENDED | | | GYPSUM CEILING. | | | | | | 2. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. IF A SUSPENDED CEILING WAS USED AS A PART | | | OF THE TEST, PROVIDE INFORMATION AS TO HOW IT HAS BEEN | | | DETERMINED THAT THIS CONDITION CURRENTLY EXISTS AND HOW | | | IT CAN BE GUARANTEED THAT THE CONDITIONS IN THE UNIT | | | BELOW WILL NOT BE ALTERED. | | | | | | 2ND REVIEW, THE TEST REPORT PROVIDED HAS A SUSPENDED | | | GYPSUM CEILING. | | | | | | 3. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM | | | E 84 OR UL 723. | | | | | | 2ND REVIEW, NOT ADDRESSED. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-01-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-01-20 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-01-20 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2015-01-20 12:24:21 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2010 | | | | | | TWO COMPLETE COLLATED SETS OF ALL DOCUMENTS REQUIRED | | | | | | 1. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | IF A SUSPENDED CEILING WAS USED AS A PART OF THE TEST, | | | PROVIDE INFORMATION AS TO HOW IT HAS BEEN DETERMINED | | | THAT THIS CONDITION CURRENTLY EXISTS AND HOW IT CAN BE | | | GUARANTEED THAT THE CONDITIONS IN THE UNIT BELOW WILL | | | NOT BE ALTERED. | | | | | | PLEASE PROVIDE A COPY OF THE TEST REPORT. | | | | | | 2. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. IF A SUSPENDED CEILING WAS USED AS A PART | | | OF THE TEST, PROVIDE INFORMATION AS TO HOW IT HAS BEEN | | | DETERMINED THAT THIS CONDITION CURRENTLY EXISTS AND HOW | | | IT CAN BE GUARANTEED THAT THE CONDITIONS IN THE UNIT | | | BELOW WILL NOT BE ALTERED. | | | | | | PLEASE PROVIDE A COPY OF THE TEST REPORT. | | | | | | 3. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM | | | E 84 OR UL 723. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-02-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-02-25 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-02-19 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2015-02-19 18:39:15 | RE-SUBMITTAL SENT TO SAMANTHA HILL FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-02-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-02-17 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-02-02 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2015-02-03 07:54:07 | RE-SUBMITTAL SENT TO SAMANTHA HILL FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-01-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-01-30 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-01-24 09:14:31 | SENT TO S. HILLS' DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-01-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-01-20 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-01-20 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2015-01-20 10:43:58 | <5000 BLDG |
|
|
|
Account Summary | Usage Policy | Privacy Policy