| 2015-01-24 10:29:16 | BUILDING PLAN REVIEW |
| | REVISION: 15010560 |
| | PERMIT: 14110435 |
| | ADD: 1270 PALM BEACH LAKES |
| | CONT: EVANS PETROLEUM |
| | TEL: (305)796-9695 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: SAT. / JAN. 24/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) SHEET A-1 DOES NOT PROVIDE DETAILS OF THE SODA |
| | FOUNTAINS, HOT OPTIONS OR HOT DOG ROTESSERIES FOR REACH |
| | RANGES NOR IF SIDE APPROACH OR FRONTAL APPROACH. NOTE |
| | THE PLANS DO INDICATE A 34 INCH COUNTER. |
| | |
| | 2010 FBC-ACCESSIBILITY 308 REACH RANGES |
| | 308.2 FORWARD REACH |
| | 308.3 SIDE REACH |
| | |
| | 309 OPERABLE PARTS |
| | 309.1 GENERAL. OPERABLE PARTS SHALL COMPLY WITH 309. |
| | 309.2 CLEAR FLOOR SPACE. A CLEAR FLOOR OR GROUND SPACE |
| | COMPLYING WITH 305 SHALL BE PROVIDED. |
| | 309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED WITHIN ONE |
| | OR MORE OF THE REACH RANGES SPECIFIED IN 308. |
| | 309.4 OPERATION. OPERABLE PARTS SHALL BE OPERABLE WITH |
| | ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, |
| | PINCHING, OR TWISTING OF THE WRIST. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |