Plan Review Details - Permit 15010554
Plan Review Stops For Permit 15010554
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-01-20 Cont ID  
Sent By jgomez Date 2015-01-20 Time 14:41 Rev Time 0.00
Received By jgomez Date 2015-01-20 Time 14:41 Sent To  
Notes
2015-01-20 14:42:151/20/15 TALKED TO JOSE. USING AH 160 ROOF TILE
 ADHESIVE. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-01-20 Cont ID  
Sent By jgomez Date 2015-01-20 Time 13:09 Rev Time 0.00
Received By jgomez Date 2015-01-20 Time 13:09 Sent To  
Notes
2015-01-20 14:14:19RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- TILE BOND ROOF TILE ADHESIVE NOA 11-0616.03
 SUBMITTED DOESN'T MEET THE DESIGN PRESSURES REQUIRED BY
 SEC. R301 OF 2010 FBC-RESIDENTIAL. NEED TO PROVIDE
 PRODUCT APPROVAL (2 COPIES) OF ROOF TILE ADHESIVE THAT
 MEETS THE DESIGN PRESSURES FOR THIS HOUSE. DCA RULE
 9N-3.
 NOTE: POLYPRO AH 160 LISTED ON THE ROOF TILE NOA
 SUBMITTED MEETS THE DESIGN PRESSURES.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected].

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-01-20 Cont ID  
Sent By jgomez Date 2015-01-20 Time 13:09 Rev Time 0.00
Received By jgomez Date 2015-01-20 Time 10:45 Sent To B
Notes
***NONE***