| Plan Review Stops For Permit 15010518 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2015-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-01-29 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-01-29 |
Time |
17:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2015-01-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-01-28 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-01-28 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2015-01-28 12:48:02 | RESIDENTIAL (R2) ALTERATION, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- PROFLEX 90 UNDERLAYMENT: PROVIDE COPIES OF THE SOUND | | | TRANSMISSION CLASS (STC) TEST DONE IN ACCORDANCE WITH | | | ASTM E 90 AND IMPACT INSULATION CLASS (IIC) TESTS DONE | | | IN ACCORDANCE TO ASTM E 492. SEC. 1207.2 AND 1207.3 OF | | | 2010 FBC-BUILDING. | | | | | | NOTE: ASSEMBLY TESTED NEED TO MATCH CONDITIONS OF | | | PROPOSED FLOOR ASSEMBLY. THE TEST REPORTS I HAVE SEEN | | | ARE FOR 8" CONCRETE SLAB SUSPENDED ACOUSTICAL CEILING. | | | ACCORDING TO CITY RECORDS THE FLOOR BETWEEN APARTMENTS | | | AT THIS ADDRESS IS 7" CONCRETE SLAB WITH NO SUSPENDED | | | CEILING ASSEMBLY. THIS IS THE KIND OF ASSEMBLY THE | | | TESTING IS REQUIRED. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-01-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-01-28 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-01-28 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2015-01-28 10:24:46 | RESIDENTIAL (R2) ALTERATION, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- ACOUSTICORK UNDERLAYMENT: PROVIDE COPIES OF THE | | | SOUND TRANSMISSION CLASS (STC) TEST DONE IN ACCORDANCE | | | WITH ASTM E 90 AND IMPACT INSULATION CLASS (IIC) TESTS | | | DONE IN ACCORDANCE TO ASTM E 492. SEC. 1207.2 AND | | | 1207.3 OF 2010 FBC-BUILDING. | | | | | | NOTE: ASSEMBLY TESTED NEED TO MATCH CONDITIONS OF | | | PROPOSED FLOOR ASSEMBLY. TESTING SUBMITTED IS FOR WOOD | | | FLOOR ASSEMBLIES. ACCORDING TO CITY RECORDS THE FLOOR | | | BETWEEN APARTMENTS IS 7" CONCRETE SLAB WITH NO | | | SUSPENDED CEILING ASSEMBLY. THIS IS THE KIND OF | | | ASSEMBLY THE TESTING IS REQUIRED. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-01-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-01-27 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-01-27 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2015-01-27 15:25:23 | RESIDENTIAL (R2) ALTERATION, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- ACOUSTICORK UNDERLAYMENT: PROVIDE COPIES OF THE | | | SOUND TRANSMISSION CLASS (STC) TEST DONE IN ACCORDANCE | | | WITH ASTM E 90 AND IMPACT INSULATION CLASS (IIC) TESTS | | | DONE IN ACCORDANCE TO ASTM E 492. SEC. 1207.2 AND | | | 1207.3 OF 2010 FBC-BUILDING. | | | NOTE: ASSEMBLY TESTED NEED TO MATCH CONDITIONS OF | | | PROPOSED FLOOR ASSEMBLY. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-01-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-01-21 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-01-21 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2015-01-21 17:53:24 | RESIDENTIAL (R2) ALTERATION, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- PROVIDE COPIES OF THE SOUND TRANSMISSION CLASS (STC) | | | TEST AND IMPACT INSULATION CLASS (IIC) TESTS DONE TO | | | THE AGGLOMERATED NATURAL CORK GRADE MC 52 SUBMITTED TO | | | SHOW COMPLIANCE WITH SEC. 1207.2 AND 1207.3 OF 2010 | | | FBC-BUILDING. | | | NOTE: INFORMATION SUBMITTED IS TOO GENERIC. IT DOESN'T | | | IDENTIFY MANUFACTURER, FIRE BEHAVIOR, THICKNESS OF | | | CONCRETE SLAB, ETC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2015-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-01-29 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-01-29 |
Time |
17:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-01-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-01-28 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-01-28 |
Time |
12:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-01-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-01-28 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-01-28 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-01-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-01-27 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-01-27 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-01-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-01-21 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-01-21 |
Time |
17:12 |
Sent To |
|
|
| Notes |
|
|