Plan Review Details - Permit 15010471
Plan Review Stops For Permit 15010471
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-01-23 Cont ID  
Sent By skennedy Date 2015-01-23 Time 13:06 Rev Time 0.00
Received By skennedy Date 2015-01-23 Time 13:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-01-21 Cont ID  
Sent By jgomez Date 2015-01-21 Time 15:41 Rev Time 0.00
Received By jgomez Date 2015-01-21 Time 07:37 Sent To  
Notes
2015-01-21 15:50:34RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC
  
 1- SOUND TRANSMISSION CLASS (STC) TEST AND IMPACT
 INSULATION CLASS (IIC) TEST SUBMITTED FOR PROFLEX MSC
 90 UNDERLAYMENT IS FOR AN 8" CONCRETE SLAB WITH AN
 ACOUSTICAL SUSPENDED CEILING ASSEMBLY. IF THE FLOOR
 CEILING ASSEMBLY IS NOT AN 8" CONCRETE SLAB WITH A
 SUSPENDED CEILING, THEN IT CAN NOT BE USED BECAUSE THE
 UNDERLAYMENT NEED TO BE INSTALLED IN FLOOR ASSEMBLY AS
 TESTED. SEC. 1207.2 AND SEC. 1207.3 OF 2010
 FBC-BUILDING. NOTE: BASED ON PRELIMINARY RESEARCH, THE
 CITY RECORDS SHOW BUILDING SECTIONS WITH 5 1/2"
 CONCRETE SLABS BETWEEN APARTMENTS. NEED TO PROVIDE
 COPIES OF TESTS DONE ON 5 1/2" CONCRETE SLABS WITH NO
 SUSPENDED CEILINGS IN ORDER TO SHOW COMPLIANCE WITH SEC
 1207.2 AND SEC. 1207.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-01-23 Cont ID  
Sent By skennedy Date 2015-01-23 Time 13:06 Rev Time 0.00
Received By skennedy Date 2015-01-23 Time 13:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-01-21 Cont ID  
Sent By jgomez Date 2015-01-21 Time 07:38 Rev Time 0.00
Received By jgomez Date 2015-01-21 Time 07:38 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved