| Plan Review Stops For Permit 15010449 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-02-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-14 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-14 |
Time |
09:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-02-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-04 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-04 |
Time |
07:17 |
Sent To |
|
|
| Notes |
| 2015-02-05 08:26:28 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SHEET S-2.0 SHOWS THAT THE ATTIC WILL BE USED | | | STORAGE. FBC-R301.5 REQUIRES A 20 PSF LIVE LOAD FOR THE | | | BOTTOM CORD OF TRUSSES USED FOR LIMITED STORAGE. | | | | | | 2) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. (1) SUBMIT THE INSTALLATION | | | INSTRUCTIONS FOR SIMPSON HETAL 12 CONNECTOR. (2) NOA | | | NO. 12-0209.13 THAT WAS SUBMITTED FOR THE 8" CAST - | | | CRETE LINTELS WAS SUPERSEDED ON 10/9/2014 BY NOA NO. | | | 14-0903.02. SUBMIT THE CURRENT ONE. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-02-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-14 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-14 |
Time |
09:57 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-02-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-05 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-05 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2015-02-05 10:35:01 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRIC | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) NEC 110.9 - SPECIFY THE A.I.C. RATING OF THE | | | ELECTRICAL SERVICE EQUIPMENT ON THE PLANS. | | | | | | 2) NEC 210.11 (C) (3) AT LEAST ONE 20 - AMP BRANCH | | | CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE | | | OUTLETS. | | | | | | 3) NEC 250.94 - INTERSYSTEM BONDING TERMINATION SHALL | | | BE PROVIDED. | | | | | | 4) NEC 250.104(B) THE GAS PIPING IS REQUIRED TO BE | | | BONDED. | | | | | | 5) NEC 210.52 (B) IN THE KITCHEN, PANTRY, BREAKFAST | | | ROOM, DINING ROOM, OR SIMILAR AREA OF A DWELLING UNIT, | | | THE TWO OR MORE 20 - AMPERE BRANCH CIRCUITS REQUIRED BY | | | 210.11 (C)(1) SHALL SERVE ALL WALL AND FLOOR RECEPTACLE | | | OUTLETS COVERED BY 210.52(C), AND RECEPTACLE OUTLETS | | | FOR REFRIGERATION EQUIPMENT. SEE EXCEPTIONS FOR | | | SWITCHED RECEPTACLES AND REFRIGERATION SUPPLIED BY AN | | | INDIVIDUAL BRANCH CIRCUIT. | | | | | | 6) FBC 107.2.1 SPECIFY THE CIRCUITS NUMBERS ON THE | | | ELECTRICAL FLOOR PLAN IN COORDINATION WITH THE PANEL | | | SCHEDULE. | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2015-02-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-02-17 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-02-17 |
Time |
07:00 |
Sent To |
|
|
| Notes |
| 2015-02-17 07:01:50 | PROVISO: SUBMIT 2 COPIES OF CODE COMPLIANT GAS RISER | | | DIAGRAM FOR REVIEW AND APPROVAL PRIOR TO ROUGH GAS | | | INSPECTION. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2015-01-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-24 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-24 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-02-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-02-17 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-02-10 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-02-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-05 |
Time |
11:45 |
Rev Time |
|
| Received By |
rmcdouga |
Date |
2015-01-15 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-01-15 16:46:21 | SENT TO R01. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
P |
Date |
2015-02-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-04 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-04 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2015-02-04 07:20:08 | MU2015-711, NO FEES WERE DUE. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2015-02-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-05 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-05 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2015-02-05 08:53:39 | LANDSCAPE PLAN IS OK PER S. GRAHAM. A SEPARATE | | | LANDSCAPE SUB-PERMIT IS REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-02-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-14 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-14 |
Time |
09:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-02-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-05 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-04 |
Time |
18:18 |
Sent To |
|
|
| Notes |
| 2015-02-05 08:06:11 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBCR-M1602.2 OUTDOOR AND RETURN AIR FOR A FORCED-AIR | | | HEATING OR COOLING SYSTEM SHALL NOT BE TAKEN FROM THE | | | FOLLOWING LOCATIONS: 4. A CLOSET, BATHROOM, TOILET | | | ROOM, KITCHEN, GARAGE, MECHANICAL ROOM, BOILER ROOM, | | | FURNACE ROOM, UNCONDITIONED ATTIC OR OTHER DWELLING | | | UNIT. RETURN CAN NOT BE IN THE KITCHEN WALL. | | | | | | 2) FBCR- M1602.4 RESTRICTED RETURN AIR OCCURS IN | | | BUILDINGS WHEN RETURNS ARE LOCATED IN CENTRAL ZONES AND | | | CLOSED INTERIOR DOORS IMPEDE AIR FLOW TO THE RETURN | | | GRILL OR WHEN CEILING SPACES ARE USED AS RETURN PLENUMS | | | AND FIRE WALLS RESTRICT AIR MOVEMENT FROM ONE PORTION | | | OF THE RETURN PLENUM TO ANOTHER. PROVISIONS SHALL BE | | | MADE IN BOTH RESIDENTIAL AND COMMERCIAL BUILDINGS TO | | | AVOID UNBALANCED AIR FLOWS AND PRESSURE DIFFERENTIALS | | | CAUSED BY RESTRICTED RETURN AIR. EXCEPTIONS: | | | 1. TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE | | | RETURN TRANSFER 1-1/2 TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT ENTERING THE ROOM OR | | | SPACE IT IS SERVING AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCH UNDERCUT TO ACHIEVE PROPER RETURN | | | AIR BALANCE. | | | 2. TRANSFER GRILLES SHALL USE 50 SQUARE INCHES (OF | | | GRILLE AREA) TO 100 CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND USING AN | | | UNRESTRICTED 1 INCH UNDERCUTTING OF DOORS TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | 3. HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET THESE | | | REQUIREMENTS FOR PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY ROOMS, | | | EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE SHALL | | | BE INCLUDED. | | | THE TRANSFER GRILLES ARE TOO SMALL IN THE MASTER | | | BEDROOM (250 CFM = 125 SQIN OF GRILL AREA) , BEDROOM 2 | | | (140 CFM = 70 SQIN OF GRILL AREA) AND BEDROOM 4 (125 | | | CFM = 62.5 SQIN OF GRILL AREA). | | | | | | 4) THERE IS WHAT APPEARS TO BE A RETURN WITH 20 CFM | | | SHOWN IN THE HALLWAY IN FRONT OF THE LINEN CLOSEST. | | | PLEASE CLARIFY. FBC 107.2.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-02-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-02-17 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-02-17 |
Time |
06:35 |
Sent To |
|
|
| Notes |
| 2015-02-17 07:00:14 | PROVISO: SUBMIT 2 COPIES OF CODE COMPLIANT SANITARY | | | RISER DIAGRAM FOR REVIEW AND APPROVAL PRIOR TO ROUGH | | | PLUMBING INSPECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-01-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-24 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-24 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2015-02-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-02-14 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-02-14 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2015-02-14 11:21:04 | OWENS CORNING ASPHALT SINGLES NOA NO.12-0309.01 | | | LOMANCO ROOF VENTS NOA NO. 13-0820.08 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2015-01-21 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2015-01-21 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-01-21 11:21:14 | NOTE: SEPARATE PERMIT REQUIRED FOR LANDSCAPING. |
|
|