Plan Review Details - Permit 15010345
| Plan Review Stops For Permit 15010345 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-04-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-04-21 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-04-21 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-01-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-01-26 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-01-26 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2015-01-26 09:48:05 | BUILDING PLAN REVIEW | | | REVISION: 15010345 | | | PERMIT: 14081143 | | | ADD: 303 BANYAN ST. # 101 | | | CONT: FISHER | | | TEL: (561)691-4716 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JAN 26/ 2015 | | | ACTION: DENIED | | | | | | 1) SHEET A1.1 THE ROOM FINISH SCHEDULE INDICATES | | | PAINTED WALLS FOR RESTROOMS, PLEASE PROVIDE COMPLIANCE | | | WITH 2010 FBC-B 1210.2 | | | WALLS AND PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF URINALS | | | AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | | NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET (1219 MM) | | | ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS, | | | THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE | | | THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | 2) SHEET A2.1 DETAIL 08 THE INSWING DOOR HAS ONLY 12 | | | INCHES FROM LATCH SIDE OF DOOR TO WALL, THE 2010 FL | | | ACCESSIBILITY CODE FIGURE 404.2.4.1 REQUIRES 18 INCHES. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-02-03 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2015-02-03 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2015-02-03 |
Time |
12:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-01-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-01-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-01-16 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-04-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-04-21 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-04-03 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-03-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-03-21 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-01-13 |
Time |
18:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2015-03-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-03-21 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-03-21 |
Time |
07:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-04-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-04-21 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-04-21 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-01-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-24 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-24 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2015-01-24 09:34:26 | 1) SHT.A1.1 - FINISH SCHEDULE - INDICATES THE WALLS IN | | | THE MEN'S AND WOMEN'S RESTROOM TO BE PAINTED. PER THE | | | 2010 FBC SEC.1210.2, WALLS AND PARTITIONS WITHIN 2 FEET | | | OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,HARD, | | | NONABSORBENT SURFACE TO A HEIGHT OF 4 FEET ABOVE THE | | | FLOOR AND THE MATERIAL SHALL BE OF A TYPE THAT IS NOT | | | ADVERSELY AFFECTED BY MOISTURE. | | | 2) SHT. A2.1 - THE HEIGHT OF THE GRAB BARS SHALL BE | | | MEASURED TO THE TOP OF THE GRIPPING SURFACE, NOT TO THE | | | CENTER LINE AS SHOWN. 2010 FAC SEC.609.4. | | | 3) SHT. P1.1 REFERS TO SHT. P0.1 FOR THE WATER HEATER | | | DETAI. THERE IS NO SUCH SHEET IN THE PLANS. PROVIDE A | | | DETAIL FOR THE WATER HEATER. THE WATER HEATER SHALL BE | | | EQUIPPED WITH A PAN AND A PAN DRAIN INSTALLED IN | | | ACCORDANCE WITH THE 2010 FPC SEC.504.7. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-02-03 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2015-02-03 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2015-02-03 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2015-02-03 08:46:51 | NEED SEPARATE PERMTI FOR AWNING. |
|
|
|