Plan Review Details - Permit 15010345
Plan Review Stops For Permit 15010345
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-04-21 Cont ID  
Sent By jwitmer Date 2015-04-21 Time 13:21 Rev Time 0.00
Received By jwitmer Date 2015-04-21 Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-01-26 Cont ID  
Sent By jwitmer Date 2015-01-26 Time 09:48 Rev Time 0.00
Received By jwitmer Date 2015-01-26 Time 07:31 Sent To  
Notes
2015-01-26 09:48:05BUILDING PLAN REVIEW
 REVISION: 15010345
 PERMIT: 14081143
 ADD: 303 BANYAN ST. # 101
 CONT: FISHER
 TEL: (561)691-4716
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JAN 26/ 2015
 ACTION: DENIED
  
 1) SHEET A1.1 THE ROOM FINISH SCHEDULE INDICATES
 PAINTED WALLS FOR RESTROOMS, PLEASE PROVIDE COMPLIANCE
 WITH 2010 FBC-B 1210.2
 WALLS AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF URINALS
 AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET (1219 MM)
 ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS,
 THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE
 THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
  
 2) SHEET A2.1 DETAIL 08 THE INSWING DOOR HAS ONLY 12
 INCHES FROM LATCH SIDE OF DOOR TO WALL, THE 2010 FL
 ACCESSIBILITY CODE FIGURE 404.2.4.1 REQUIRES 18 INCHES.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-02-03 Cont ID  
Sent By rlecky Date 2015-02-03 Time 12:43 Rev Time 0.00
Received By rlecky Date 2015-02-03 Time 12:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-01-16 Cont ID  
Sent By pleduc Date 2015-01-16 Time   Rev Time 0.00
Received By pleduc Date 2015-01-16 Time 11:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-04-21 Cont ID  
Sent By jwitmer Date 2015-04-21 Time 13:21 Rev Time 0.00
Received By jwitmer Date 2015-04-03 Time   Sent To  
Notes
2015-04-04 09:56:49B27

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-21 Cont ID  
Sent By hmoser Date 2015-03-21 Time 08:01 Rev Time 0.00
Received By hmoser Date 2015-01-13 Time 18:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2015-03-21 Cont ID  
Sent By hmoser Date 2015-03-21 Time 08:01 Rev Time 0.00
Received By hmoser Date 2015-03-21 Time 07:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-04-21 Cont ID  
Sent By tklarge Date 2015-04-21 Time 08:58 Rev Time 0.00
Received By tklarge Date 2015-04-21 Time 08:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-01-26 Cont ID  
Sent By tklarge Date 2015-01-24 Time 09:50 Rev Time 0.00
Received By tklarge Date 2015-01-24 Time 09:05 Sent To  
Notes
2015-01-24 09:34:261) SHT.A1.1 - FINISH SCHEDULE - INDICATES THE WALLS IN
 THE MEN'S AND WOMEN'S RESTROOM TO BE PAINTED. PER THE
 2010 FBC SEC.1210.2, WALLS AND PARTITIONS WITHIN 2 FEET
 OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,HARD,
 NONABSORBENT SURFACE TO A HEIGHT OF 4 FEET ABOVE THE
 FLOOR AND THE MATERIAL SHALL BE OF A TYPE THAT IS NOT
 ADVERSELY AFFECTED BY MOISTURE.
 2) SHT. A2.1 - THE HEIGHT OF THE GRAB BARS SHALL BE
 MEASURED TO THE TOP OF THE GRIPPING SURFACE, NOT TO THE
 CENTER LINE AS SHOWN. 2010 FAC SEC.609.4.
 3) SHT. P1.1 REFERS TO SHT. P0.1 FOR THE WATER HEATER
 DETAI. THERE IS NO SUCH SHEET IN THE PLANS. PROVIDE A
 DETAIL FOR THE WATER HEATER. THE WATER HEATER SHALL BE
 EQUIPPED WITH A PAN AND A PAN DRAIN INSTALLED IN
 ACCORDANCE WITH THE 2010 FPC SEC.504.7.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2015-02-03 Cont ID  
Sent By aaponte Date 2015-02-03 Time 08:46 Rev Time 0.00
Received By aaponte Date 2015-02-03 Time 08:46 Sent To  
Notes
2015-02-03 08:46:51NEED SEPARATE PERMTI FOR AWNING.