Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-05-07 Cont ID  
Sent By rmcdouga Date 2015-05-07 Time 13:35 Rev Time 0.00
Received By rmcdouga Date 2015-05-07 Time 06:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-03-04 Cont ID  
Sent By rmcdouga Date 2015-03-04 Time 09:56 Rev Time 0.00
Received By rmcdouga Date 2015-02-26 Time 11:23 Sent To  
Notes
2015-03-03 14:59:58PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE SOIL REPORT STATES THAT A TWENTY ( 20) INCH WIDE
 FOOTING IS REQUIRED AND THE PLANS ARE FOR AN EIGHTEEN
 (18) INCH WIDE FOOTING. FBC 107.2.1
  
 2) THE ENERGY CALCULATION FORM SPECIFIES ONE (1)
 BEDROOM AND THE PLANS HAVE THREE (3) BEDROOMS. PLEASE
 CORRECT. FBC 107.2.1
  
 3) THE INFORMATION FOR THE ISOLATED FOOTERS AT THE REAR
 PORCH ARE ILLEGIBLE DUE TO BEING PRINTED OVER ON THE
 PLANS. FBC 107.2.1
  
 4) FBC 107.3.5.3 - PROVIDE WIND DESIGN DATA (IE.
 WINDSPEED, EXPOSURE CATEGORY, ETC.)ON THE PLANS
 PURSUANT TO FBC-R301.2.
  
 5) R803.2.3.1 SHEATHING FASTENINGS.
 WOOD STRUCTURAL PANEL SHEATHING SHALL BE FASTENED TO
 ROOF FRAMING WITH 8D RING-SHANK NAILS AT 6 INCHES ON
 CENTER AT EDGES AND 6 INCHES ON CENTER AT INTERMEDIATE
 FRAMING. RING-SHANK NAILS SHALL HAVE THE FOLLOWING
 MINIMUM DIMENSIONS:
 1. 0.113 INCH NOMINAL SHANK DIAMETER.
 2. RING DIAMETER OF 0.012 OVER SHANK DIAMETER.
 3. 16 TO 20 RINGS PER INCH.
 4. 0.280 INCH FULL ROUND HEAD DIAMETER.
 5. 2 INCH NAIL LENGTH.
 WHERE ROOF FRAMING WITH A SPECIFIC GRAVITY, 0.42 < OR =
 G < 0.49 IS USED, SPACING OF RING-SHANK FASTENERS SHALL
 BE 4 INCHES ON CENTER IN NAILING ZONE 3 IN ACCORDANCE
 WITH FIGURE R803.2.3.1 WHERE VASD AS DETERMINED IN
 ACCORDANCE WITH SECTION R301.2.1.3 IS 130 MPH OR
 GREATER.
  
 6) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3
 THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. (1) THE PRODUCT APPROVALS THAT WERE
 SUBMITTED FOR THE JELD-WEN OUT SWING OPAQUE DOOR WITH
 SIDELITES DOES NOT HAVE THE FL# INDICATED ON THE
 DOCUMENTS THAT WERE SUBMITTED. (2) NO PRODUCT APPROVALS
 WERE SUBMITTED FOR THE FIXED GLASS WINDOW ABOVE THE
 FRONT DOOR. (3) PRODUCT APPROVALS WERE SUBMITTED FOR A
 JELD WEN INSWING GLAZED DOOR SYSTEM WITH SIDELITES (NOA
 NO. 09-0608.15) , HOWEVER THE PLANS DO NOT SHOW ANY
 INSWING DOORS.
  
 7) THE VALUATION THAT WAS SUBMITTED FOR THIS STRUCTURE
 IS LOW BASED ON THE CURRENT ICC VALUATION DATA. THE
 CALCULATED VALUE FOR DETERMINING PERMIT FEES IS
 $173,945.00. THE VALUATION HAS BEEN ADJUSTED
 ACCORDINGLY. FBC 109.3
  
 IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE
 CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER
 INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN
 ADDRESSED.
  
 RE-SUBMITTAL PROCEDURE
  
 YOU ARE REQUIRED TO FILL OUT A RE-SUBMITTAL FORM TO BE
 SUBMITTED WITH THE CORRECTED PLANS AND/OR OTHER
 DOCUMENTS.
 THE PERMIT CLERK WILL RETRIEVE THE DENIED APPLICATION,
 PLANS AND OTHER DOCUMENTS FOR YOU.
 YOU ARE REQUIRED TO REMOVE THE OLD PLAN SHEETS THAT
 HAVE BEEN CORRECTED AND REPLACE THEM WITH THE NEW ONES.
 THE CLERK WILL PROVIDE YOU WITH A STAPLE REMOVER AND A
 STAPLER. ONE SET OF THE OLD PLAN SHEETS THAT HAVE BEEN
 REMOVED SHALL BE MARKED AS VOIDED AND RESUBMITTED ALONG
 WITH THE TWO (OR MORE) SETS THAT CONTAIN THE CORRECTED
 SHEETS. IF THERE ARE ANY SHEETS THAT HAVE BEEN STAMPED
 FOR COUNTY IMPACT FEES, HOA APPROVAL STAMPS OR OTHERS,
 RESUBMIT THOSE SHEETS.
 IF ALL OF THE PLAN SHEETS HAVE BEEN CORRECTED, THEN TWO
 (OR MORE) SETS OF THE NEW PLANS AND ANY OTHER DOCUMENTS
 SHALL BE SUBMITTED.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-03-03 Cont ID  
Sent By rmcdouga Date 2015-03-03 Time 11:34 Rev Time 0.00
Received By rmcdouga Date 2015-03-02 Time 14:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-05-07 Cont ID  
Sent By rmcdouga Date 2015-05-07 Time 13:35 Rev Time 0.00
Received By rmcdouga Date 2015-04-25 Time 07:58 Sent To  
Notes
2015-04-25 07:59:10SENT TO R MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-03-04 Cont ID  
Sent By rmcdouga Date 2015-03-04 Time 09:56 Rev Time  
Received By rmcdouga Date 2015-01-08 Time   Sent To  
Notes
2015-01-09 08:03:25INCOMING SENT TO R06. JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2015-05-14 Cont ID  
Sent By ndaniels Date 2015-05-14 Time 16:29 Rev Time 0.00
Received By ndaniels Date 2015-05-14 Time 16:29 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-05-07 Cont ID  
Sent By rmcdouga Date 2015-05-07 Time 08:05 Rev Time 0.00
Received By rmcdouga Date 2015-05-07 Time 06:54 Sent To  
Notes
2015-05-07 08:06:05BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-02-26 Cont ID  
Sent By rmcdouga Date 2015-02-26 Time 11:22 Rev Time 0.00
Received By rmcdouga Date 2015-02-26 Time 11:22 Sent To  
Notes
2015-02-26 11:22:59BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-05-07 Cont ID  
Sent By rmcdouga Date 2015-05-07 Time 08:05 Rev Time 0.00
Received By rmcdouga Date 2015-05-07 Time 06:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-03-02 Cont ID  
Sent By rmcdouga Date 2015-03-02 Time 12:57 Rev Time 0.00
Received By rmcdouga Date 2015-03-02 Time 12:57 Sent To  
Notes
2015-03-02 13:37:07PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC-R - M 1602.4 PROVIDE BALANCED AIR RETURN AT THE
 MASTER BEDROOM SUITE.
  
 2) THE ENERGY FORM (405-10) THAT WAS SUBMITTED LISTS
 THE NUMBER OF BEDROOMS AS (1) ONE AND THE PLANS SHOW
 (3) THREE BEDROOMS. PLEASE CORRECT. FBC 107.2.1
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2015-01-17 Cont ID  
Sent By tklarge Date 2015-01-17 Time 02:29 Rev Time 0.00
Received By tklarge Date 2015-01-16 Time 14:25 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2015-05-07 Cont ID  
Sent By rmcdouga Date 2015-05-07 Time 14:12 Rev Time 0.00
Received By rmcdouga Date 2015-05-07 Time 14:12 Sent To  
Notes
2015-05-07 14:14:53GAF TIMBERLINE SHINGLES, NOA NO. 13-0419.04

Review Stop Z ZONING
Rev No 1 Status P Date 2015-01-21 Cont ID  
Sent By sgraham Date 2015-01-21 Time 10:03 Rev Time 0.00
Received By sgraham Date 2015-01-21 Time 10:03 Sent To  
Notes
2015-01-21 10:05:221/20/15 ZONING PASSED.
  
 SEPARATE PLANS AND PERMIT REQUIRED FOR LANDSCAPING. SEE
 94-442 (2) A IN THE ZONING CODE.