Plan Review Details - Permit 15010184
Plan Review Stops For Permit 15010184
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-03-03 Cont ID  
Sent By jwitmer Date 2015-03-03 Time 14:36 Rev Time 0.00
Received By jwitmer Date 2015-03-03 Time   Sent To  
Notes
2015-03-03 14:37:11TO BE USED AS A CONSTRUCTION OFFICE ONLY, NOT A SALES
 OFFICE, NO IMPACT FEES WERE COLLECTED!!!!! JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-03-02 Cont ID  
Sent By jwitmer Date 2015-03-02 Time 10:36 Rev Time 0.00
Received By jwitmer Date 2015-03-02 Time 10:36 Sent To  
Notes
2015-03-02 10:36:46BUILDING PLAN REVIEW
 PERMIT: 15010184
 ADD: 3775 N. MILITARY TRL
 CONT: KENNEDY HOMES, LLC
 TEL: ( 561)613-6917
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. MARCH 02/2015
 ACTION: DENIED
  
 NOTICE: CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES
 THAT A LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR
 TIMES THE FEE FOR
 PLAN REVIEW, IF PLANS ARE REJECTED (3) OR MORE TIMES
 FOR REPEATED FAILURE TO CORRECT A CODE VIOLATION.
  
  
 1) THE LENGTH OF TIME THIS MANUFACTURED BUILDING IS TO
 BE ON SITE HAS NOT BEEN PROVIDED, IF TEMPORARY OR NOT.
 THE DEFINITION OF TEMPORARY:
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION 108.1
 GENERAL. THE BUILDING OFFICIAL IS AUTHORIZED TO ISSUE A
 PERMIT FOR TEMPORARY STRUCTURES AND TEMPORARY USES.
 SUCH PERMITS SHALL BE LIMITED AS TO TIME OF SERVICE,
 BUT SHALL NOT BE PERMITTED FOR MORE THAN 6 MONTHS.
  
 FOR THE PURPOSE OF THIS REVIEW, THE LENGTH OF TIME WILL
 NOT BE TEMPORARY OR THE MANUFACTURED BUILDING WILL BE
 ON SITE OVER 6 MONTHS OF USAGE.
  
 THE S1 SHEET SHOWS A FOUNDATION SYSTEM THAT WILL BE
 USED FOR TEMPORARY FOUNDATIONS, THIS SYSTEM DOES NOT
 COMPLY WITH SECTION 2010 FBC-B
 1809.4 DEPTH AND WIDTH OF FOOTINGS.
 THE MINIMUM DEPTH OF FOOTINGS BELOW THE UNDISTURBED
 GROUND SURFACE SHALL BE 12 INCHES (305 MM). WHERE
 APPLICABLE, THE REQUIREMENTS OF SECTION 1809.5 SHALL
 ALSO BE SATISFIED. THE MINIMUM WIDTH OF FOOTINGS SHALL
 BE 12 INCHES (305 MM).
  
 2) THE MANUFACTURED BUILDING PLAN IS A STATE APPROVED
 PLAN. SHEET 1 OF 4 INDICATES SITE INSTALLED ITEMS THAT
 ARE NOT PART OF THE STATE APPROVAL:
  
 2A) SEMI- COMPLIED. COMPLETE FOUNDATION SUPPORT AND TIE
 -DOWN NO FOUNDATION PLAN ONLY THE TIE DOWN.
 2B) SEMI COMPLIED SEE NEW COMMENTS. RAMPS. STAIRS
 HANDRAILS & GUARDRAILS
 2C) STORM SHUTTERS : NO PRODUCT APPROVAL FOR SHUTTER
 SUBMITTED.
 2D) GUTTERS : PROVISO TO BE INSPECTED AT TIME OF
 INSPACTION.
  
 3) 2ND REQUEST. THE MANUFACTURED BUILDING SHOWS (2)
 EXITS, NOTE ON THE PLANS INDICATES METAL STAIRS TO
 CONSTRUCTION OFFICE BY OTHERS, PLEASE PROVIDE
 COMPLIANCE WITH, 2010 FBC-B:
 1009.4 STAIR TREADS AND RISERS. STAIR TREADS AND RISERS
 SHALL COMPLY WITH SECTIONS 1009.4.1 THROUGH 1009.4.5.
  
 1012.1 WHERE REQUIRED. HANDRAILS FOR STAIRWAYS AND
 RAMPS SHALL BE ADEQUATE IN STRENGTH AND ATTACHMENT IN
 ACCORDANCE WITH SECTION 1607.7. HANDRAILS REQUIRED FOR
 STAIRWAYS BY SECTION 1009.12 SHALL COMPLY WITH SECTIONS
 1012.2 THROUGH 1012.9. HANDRAILS REQUIRED FOR RAMPS BY
 SECTION 1010.8 SHALL COMPLY WITH SECTIONS 1012.2
 THROUGH 1012.8.
  
 1013.1 WHERE REQUIRED. GUARDS SHALL BE LOCATED ALONG
 OPEN-SIDED WALKING SURFACES, INCLUDING MEZZANINES,
 EQUIPMENT PLATFORMS, STAIRS, RAMPS AND LANDINGS THAT
 ARE LOCATED MORE THAN 30 INCHES (762 MM) MEASURED
 VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT
 WITHIN 36 INCHES (914 MM) HORIZONTALLY TO THE EDGE OF
 THE OPEN SIDE. GUARDS SHALL BE ADEQUATE IN STRENGTH AND
 ATTACHMENT IN ACCORDANCE WITH SECTION 1607.7.
  
 4) SHEET S1 ON THE OVERALL STAIR AND RAMP DETAIL:
 4A) PLEASE PROVIDE A BOTTOM LANDING TO THE RAMP IN
 COMPLIANCE WITH2010 FBC-B 1010.6 LANDINGS. RAMPS SHALL
 HAVE LANDINGS AT THE BOTTOM AND TOP OF EACH RAMP,
 POINTS OF TURNING, ENTRANCE, EXITS AND AT DOORS AND IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE,
 ACCESSIBILITY. LANDINGS SHALL COMPLY WITH SECTIONS
 1010.6.1 THROUGH 1010.6.5.
  
 4B) 1010.6.4 CHANGE IN DIRECTION. WHERE CHANGES IN
 DIRECTION OF TRAVEL OCCUR AT LANDINGS PROVIDED BETWEEN
 RAMP RUNS, THE LANDING SHALL BE 60 INCHES BY 60 INCHES
 (1524 MM BY 1524 MM) MINIMUM.
  
 4C) THE ACCESSIBLE DOORWAY NEXT TO THE RAMP IS LOCATED
 18 INCHES FROM THE BEGINNING OF THE RAMP. FBC-B
 1010.6.5 DOORWAYS. WHERE DOORWAYS ARE LOCATED ADJACENT
 TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY
 ICC A117.1 ARE PERMITTED TO OVERLAP THE REQUIRED
 LANDING AREA. FL. ACCESSIBILITY CODE FIHURE 404.2.4.1
 (H) LATCH APPROACH, PULL SIDE.
  
 4D) THE DETAIL # 1 SHOWS A 2X4 TO BE USED AS A
 HANDRAIL, PLEASE SHOW COMPLIANCE WITH 2010 FBC-B 1012.3
 HANDRAIL GRASPABILITY TYPE I OR TYPE II.
  
 4E) SHEET S1 DETAIL # 3 SHOWS STAIRS WITH A HANDRAIL
 THIS IS TO BE AN ACCESSIBLE STAIR IN COMPLIANCE WITH
 2010 FBC- 1012.6 HANDRAIL EXTENSIONS.
 HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING
 SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN
 ADJACENT STAIR FLIGHT OR RAMP RUN. WHERE HANDRAILS ARE
 NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL
 EXTEND HORIZONTALLY AT LEAST 12 INCHES (305 MM) BEYOND
 THE TOP RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF
 ONE TREAD BEYOND THE BOTTOM RISER. AT RAMPS WHERE
 HANDRAILS ARE NOT CONTINUOUS BETWEEN RUNS, THE
 HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING
 12 INCHES (305 MM) MINIMUM BEYOND THE TOP AND BOTTOM OF
 RAMP RUNS. THE EXTENSIONS OF HANDRAILS SHALL BE IN THE
 SAME DIRECTION OF THE STAIR FLIGHTS AT STAIRWAYS AND
 THE RAMP RUNS AT RAMPS.
  
 4F) NOTE # 3 INDICATES THE LIVE LOADS AT 60 PSF, PLEASE
 REVIEW THE 2010 FBC-B TABLE 1607.1(35) STAIRS 100 PSF
 STAIRS AND EXITS.
  
 5) NEW COMMENT SHEET S1:
  
 5A) THE STAIRS SHOW A VERTICAL RISE OF 7 1/8 INCHES.
 PLEASE REFER TO SECTION 2010 FBC-B 1009.4.2 STAIR RISER
 HEIGHTS SHALL BE 7 INCHES (178 MM) MAXIMUM AND 4 INCHES
 (102 MM) MINIMUM.
  
 5B) WITH THE FLOOR PLAN SHOWING 4 RISERS @ 7 1/8 IN. =
 28 1/2 INCHES. PLEASE NOTE IF THE TOP LANDING IS AT 28
 1/2 INCHES ABOVE GRADE THE RAMP SHOULD BE 28 + FEET
 LONG OR PROVIDE THE ELEVATION DIFFERENCE IN GRADE FOR
 THE ACCESSIBLE PARKING, THE BOTTOM LANDING TOP LANDING
 AND THE BOTTOM OF THE STAIRS.
 FBC-B 1010.2 SLOPE.
 RAMPS USED AS PART OF A MEANS OF EGRESS SHALL HAVE A
 RUNNING SLOPE NOT STEEPER THAN ONE UNIT VERTICAL IN 12
 UNITS HORIZONTAL (8.333-PERCENT SLOPE). THE SLOPE OF
 OTHER PEDESTRIAN RAMPS SHALL NOT BE STEEPER THAN ONE
 UNIT VERTICAL IN EIGHT UNITS HORIZONTAL (12.5-PERCENT
 SLOPE).
  
 5C) THE RAMP CROSS SECTION NOR DOES THE STAIR ELEVATION
 PROVIDE THE HEIGHT OF THE HANDRAIL PER:
 2010 FBC-B HANDRAIL HEIGHT, MEASURED ABOVE STAIR TREAD
 NOSINGS, OR FINISH SURFACE OF RAMP SLOPE, SHALL BE
 UNIFORM, NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE
 THAN 38 INCHES (965 MM).
  
 5D) NOTE ONLY NO ACTION REQUIRED!!!! THE PLANS DO NOT
 INDICATE THE MODULAR BUILDING BEING SET 30 INCHES ABOVE
 GRADE, NOTE IF SO FBC-B SECTION 1013.1-3 WILL BE
 REQUIRED.
  
 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
 4B)
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-01-26 Cont ID  
Sent By jwitmer Date 2015-01-26 Time 07:13 Rev Time 0.00
Received By jwitmer Date 2015-01-26 Time 05:54 Sent To  
Notes
2015-01-26 07:13:54BUILDING PLAN REVIEW
 PERMIT: 15010184
 ADD: 3775 N. MILITARY TRL
 CONT: KENNEDY HOMES, LLC
 TEL: ( 561)613-6917
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JAN. 26/ 2015
 ACTION: DENIED
  
 1) THE LENGHT OF TIME THIS MANUFACTURED BUILDING IS TO
 BE ON SITE HAS NOT BEEN PROVIDED, IF TEMPORARY OR NOT.
 THE DEFINITION OF TEMPORARY:
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION 108.1
 GENERAL. THE BUILDING OFFICIAL IS AUTHORIZED TO ISSUE A
 PERMIT FOR TEMPORARY STRUCTURES AND TEMPORARY USES.
 SUCH PERMITS SHALL BE LIMITED AS TO TIME OF SERVICE,
 BUT SHALL NOT BE PERMITTED FOR MORE THAN 6MONTHS.
  
 FOR THE PURPOSE OF THIS REVIEW, THE LENGHT OF TIME WILL
 NOT BE TEMPORARY OR THE MANUFACTURED BUILDING WILL BE
 ON SITE OVER 6 MONTHS OF USAGE.
  
 THE S1 SHEET SHOWS A FOUNDATION SYSTEM THAT WILL BE
 USED FOR TEMPARAY FOUNDATIONS, THIS SYSTEM DOES NOT
 COMPLY WITH SECTION 2010 FBC-B
 1809.4 DEPTH AND WIDTH OF FOOTINGS.
 THE MINIMUM DEPTH OF FOOTINGS BELOW THE UNDISTURBED
 GROUND SURFACE SHALL BE 12 INCHES (305 MM). WHERE
 APPLICABLE, THE REQUIREMENTS OF SECTION 1809.5 SHALL
 ALSO BE SATISFIED. THE MINIMUM WIDTH OF FOOTINGS SHALL
 BE 12 INCHES (305 MM).
  
 2) THE MANUFACTURED BUILDING PLAN IS A STATE APPROVED
 PLAN. SHEET 1 OF 4 INDICATES SITE INSTALLED ITEMS THAT
 ARE NOT PART OF THE STATE APPROVAL:
  
 2A) COMPLETE FOUNDATIONSUPPORT AND TIE -DOWN
 2B) RAMPS. STAIRS HANDRAILS & GUARDRAILS
 2C) STORM SHUTTERS & GUTTERS
 2D) STORM SHUTTERS
  
 3) THE MANUFACTURED BUILDING SHOWS (2) EXITS, NOTE ON
 THE PLANS INDICATES METAL STAIRS TO CONSTRUCTION OFFICE
 BY OTHERS, PLEASE PROVIDE COMPLIANCE WITH, 2010 FBC-B:
 1009.4 STAIR TREADS AND RISERS. STAIR TREADS AND RISERS
 SHALL COMPLY WITH SECTIONS 1009.4.1 THROUGH 1009.4.5.
  
 1012.1 WHERE REQUIRED. HANDRAILS FOR STAIRWAYS AND
 RAMPS SHALL BE ADEQUATE IN STRENGTH AND ATTACHMENT IN
 ACCORDANCE WITH SECTION 1607.7. HANDRAILS REQUIRED FOR
 STAIRWAYS BY SECTION 1009.12 SHALL COMPLY WITH SECTIONS
 1012.2 THROUGH 1012.9. HANDRAILS REQUIRED FOR RAMPS BY
 SECTION 1010.8 SHALL COMPLY WITH SECTIONS 1012.2
 THROUGH 1012.8.
  
 1013.1 WHERE REQUIRED. GUARDS SHALL BE LOCATED ALONG
 OPEN-SIDED WALKING SURFACES, INCLUDING MEZZANINES,
 EQUIPMENT PLATFORMS, STAIRS, RAMPS AND LANDINGS THAT
 ARE LOCATED MORE THAN 30 INCHES (762 MM) MEASURED
 VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT
 WITHIN 36 INCHES (914 MM) HORIZONTALLY TO THE EDGE OF
 THE OPEN SIDE. GUARDS SHALL BE ADEQUATE IN STRENGTH AND
 ATTACHMENT IN ACCORDANCE WITH SECTION 1607.7.
  
 4) SHEET S1 ON THE OVERALL STAIR AND RAMP DETAIL:
 4A) PLEASE PROVIDE A BOTTOM LANDING TO THE RAMP IN
 COMPLIANCE WITH2010 FBC-B 1010.6 LANDINGS. RAMPS SHALL
 HAVE LANDINGS AT THE BOTTOM AND TOP OF EACH RAMP,
 POINTS OF TURNING, ENTRANCE, EXITS AND AT DOORS AND IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE,
 ACCESSIBILITY. LANDINGS SHALL COMPLY WITH SECTIONS
 1010.6.1 THROUGH 1010.6.5.
  
 4B) 1010.6.4 CHANGE IN DIRECTION. WHERE CHANGES IN
 DIRECTION OF TRAVEL OCCUR AT LANDINGS PROVIDED BETWEEN
 RAMP RUNS, THE LANDING SHALL BE 60 INCHES BY 60 INCHES
 (1524 MM BY 1524 MM) MINIMUM.
  
 4C) THE ACCESSIBLE DOORWAY NEXT TO THE RAMP IS LOCATED
 18 INCHES FROM THE BEGINNING OF THE RAMP. FBC-B
 1010.6.5 DOORWAYS. WHERE DOORWAYS ARE LOCATED ADJACENT
 TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY
 ICC A117.1 ARE PERMITTED TO OVERLAP THE REQUIRED
 LANDING AREA. FL. ACCESSIBILITY CODE FIHURE 404.2.4.1
 (H) LATCH APPROACH, PULL SIDE.
  
 4D) THE DETAIL # 1 SHOWS A 2X4 TO BE USED AS A
 HANDRAIL, PLEASE SHOW COMPLIANCE WITH 2010 FBC-B 1012.3
 HANDRAIL GRASPABILITY TYPE I OR TYPE II.
  
 4E) SHEET S1 DETAIL # 3 SHOWS STAIRS WITH A HANDRAIL
 THIS IS TO BE AN ACCESSIBLE STAIR IN COMPLIANCE WITH
 2010 FBC- 1012.6 HANDRAIL EXTENSIONS.
 HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING
 SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN
 ADJACENT STAIR FLIGHT OR RAMP RUN. WHERE HANDRAILS ARE
 NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL
 EXTEND HORIZONTALLY AT LEAST 12 INCHES (305 MM) BEYOND
 THE TOP RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF
 ONE TREAD BEYOND THE BOTTOM RISER. AT RAMPS WHERE
 HANDRAILS ARE NOT CONTINUOUS BETWEEN RUNS, THE
 HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING
 12 INCHES (305 MM) MINIMUM BEYOND THE TOP AND BOTTOM OF
 RAMP RUNS. THE EXTENSIONS OF HANDRAILS SHALL BE IN THE
 SAME DIRECTION OF THE STAIR FLIGHTS AT STAIRWAYS AND
 THE RAMP RUNS AT RAMPS.
  
 4F) NOTE # 3 INDICATES THE LIVE LOADS AT 60 PSF, PLEASE
 REVIEW THE 2010 FBC-B TABLE 1607.1(35) STAIRS 100 PSF
 STAIRS AND EXITS.
  
 5) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
 4B)
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-02-10 Cont ID  
Sent By skennedy Date 2015-02-10 Time 08:37 Rev Time 0.00
Received By skennedy Date 2015-02-10 Time 08:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2015-01-27 Cont ID  
Sent By skennedy Date 2015-01-27 Time 13:12 Rev Time 0.00
Received By skennedy Date 2015-01-27 Time 13:12 Sent To  
Notes
2015-01-27 13:13:48NO ELECTRICAL DETAILS WERE PROVIDED FOR THE REQUIRED
 ELECTRICAL SERVICE. APPLICANT MAY CHOOSE TO SUBMIT
 DETAILS WITH RE-SUBMITTAL OR TO HAVE ELECTRICIAN SUBMIT
 SEPERATELY.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-02-17 Cont ID  
Sent By pleduc Date 2015-02-17 Time   Rev Time 0.00
Received By pleduc Date 2015-02-17 Time 15:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-01-15 Cont ID  
Sent By pleduc Date 2015-01-15 Time   Rev Time 0.00
Received By pleduc Date 2015-01-12 Time 16:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-03-03 Cont ID  
Sent By tklarge Date 2015-03-03 Time 14:49 Rev Time 0.00
Received By tklarge Date 2015-03-03 Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status F Date 2015-03-02 Cont ID  
Sent By jwitmer Date 2015-03-02 Time 10:35 Rev Time 0.00
Received By jwitmer Date 2015-02-09 Time 08:31 Sent To  
Notes
2015-03-02 10:29:40BUILDING PLAN REVIEW
 PERMIT: 15010184
 ADD: 3775 N. MILITARY TRL
 CONT: KENNEDY HOMES, LLC
 TEL: ( 561)613-6917
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. MARCH 02/2015
 ACTION: DENIED
  
 NOTICE: CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES
 THAT A LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR
 TIMES THE FEE FOR
 PLAN REVIEW, IF PLANS ARE REJECTED (3) OR MORE TIMES
 FOR REPEATED FAILURE TO CORRECT A CODE VIOLATION.
  
  
 1) THE LENGTH OF TIME THIS MANUFACTURED BUILDING IS TO
 BE ON SITE HAS NOT BEEN PROVIDED, IF TEMPORARY OR NOT.
 THE DEFINITION OF TEMPORARY:
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION 108.1
 GENERAL. THE BUILDING OFFICIAL IS AUTHORIZED TO ISSUE A
 PERMIT FOR TEMPORARY STRUCTURES AND TEMPORARY USES.
 SUCH PERMITS SHALL BE LIMITED AS TO TIME OF SERVICE,
 BUT SHALL NOT BE PERMITTED FOR MORE THAN 6 MONTHS.
  
 FOR THE PURPOSE OF THIS REVIEW, THE LENGTH OF TIME WILL
 NOT BE TEMPORARY OR THE MANUFACTURED BUILDING WILL BE
 ON SITE OVER 6 MONTHS OF USAGE.
  
 THE S1 SHEET SHOWS A FOUNDATION SYSTEM THAT WILL BE
 USED FOR TEMPORARY FOUNDATIONS, THIS SYSTEM DOES NOT
 COMPLY WITH SECTION 2010 FBC-B
 1809.4 DEPTH AND WIDTH OF FOOTINGS.
 THE MINIMUM DEPTH OF FOOTINGS BELOW THE UNDISTURBED
 GROUND SURFACE SHALL BE 12 INCHES (305 MM). WHERE
 APPLICABLE, THE REQUIREMENTS OF SECTION 1809.5 SHALL
 ALSO BE SATISFIED. THE MINIMUM WIDTH OF FOOTINGS SHALL
 BE 12 INCHES (305 MM).
  
 2) THE MANUFACTURED BUILDING PLAN IS A STATE APPROVED
 PLAN. SHEET 1 OF 4 INDICATES SITE INSTALLED ITEMS THAT
 ARE NOT PART OF THE STATE APPROVAL:
  
 2A) SEMI- COMPLIED. COMPLETE FOUNDATION SUPPORT AND TIE
 -DOWN NO FOUNDATION PLAN ONLY THE TIE DOWN.
 2B) SEMI COMPLIED SEE NEW COMMENTS. RAMPS. STAIRS
 HANDRAILS & GUARDRAILS
 2C) STORM SHUTTERS : NO PRODUCT APPROVAL FOR SHUTTER
 SUBMITTED.
 2D) GUTTERS : PROVISO TO BE INSPECTED AT TIME OF
 INSPACTION.
  
 3) 2ND REQUEST. THE MANUFACTURED BUILDING SHOWS (2)
 EXITS, NOTE ON THE PLANS INDICATES METAL STAIRS TO
 CONSTRUCTION OFFICE BY OTHERS, PLEASE PROVIDE
 COMPLIANCE WITH, 2010 FBC-B:
 1009.4 STAIR TREADS AND RISERS. STAIR TREADS AND RISERS
 SHALL COMPLY WITH SECTIONS 1009.4.1 THROUGH 1009.4.5.
  
 1012.1 WHERE REQUIRED. HANDRAILS FOR STAIRWAYS AND
 RAMPS SHALL BE ADEQUATE IN STRENGTH AND ATTACHMENT IN
 ACCORDANCE WITH SECTION 1607.7. HANDRAILS REQUIRED FOR
 STAIRWAYS BY SECTION 1009.12 SHALL COMPLY WITH SECTIONS
 1012.2 THROUGH 1012.9. HANDRAILS REQUIRED FOR RAMPS BY
 SECTION 1010.8 SHALL COMPLY WITH SECTIONS 1012.2
 THROUGH 1012.8.
  
 1013.1 WHERE REQUIRED. GUARDS SHALL BE LOCATED ALONG
 OPEN-SIDED WALKING SURFACES, INCLUDING MEZZANINES,
 EQUIPMENT PLATFORMS, STAIRS, RAMPS AND LANDINGS THAT
 ARE LOCATED MORE THAN 30 INCHES (762 MM) MEASURED
 VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT
 WITHIN 36 INCHES (914 MM) HORIZONTALLY TO THE EDGE OF
 THE OPEN SIDE. GUARDS SHALL BE ADEQUATE IN STRENGTH AND
 ATTACHMENT IN ACCORDANCE WITH SECTION 1607.7.
  
 4) SHEET S1 ON THE OVERALL STAIR AND RAMP DETAIL:
 4A) PLEASE PROVIDE A BOTTOM LANDING TO THE RAMP IN
 COMPLIANCE WITH2010 FBC-B 1010.6 LANDINGS. RAMPS SHALL
 HAVE LANDINGS AT THE BOTTOM AND TOP OF EACH RAMP,
 POINTS OF TURNING, ENTRANCE, EXITS AND AT DOORS AND IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE,
 ACCESSIBILITY. LANDINGS SHALL COMPLY WITH SECTIONS
 1010.6.1 THROUGH 1010.6.5.
  
 4B) 1010.6.4 CHANGE IN DIRECTION. WHERE CHANGES IN
 DIRECTION OF TRAVEL OCCUR AT LANDINGS PROVIDED BETWEEN
 RAMP RUNS, THE LANDING SHALL BE 60 INCHES BY 60 INCHES
 (1524 MM BY 1524 MM) MINIMUM.
  
 4C) THE ACCESSIBLE DOORWAY NEXT TO THE RAMP IS LOCATED
 18 INCHES FROM THE BEGINNING OF THE RAMP. FBC-B
 1010.6.5 DOORWAYS. WHERE DOORWAYS ARE LOCATED ADJACENT
 TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY
 ICC A117.1 ARE PERMITTED TO OVERLAP THE REQUIRED
 LANDING AREA. FL. ACCESSIBILITY CODE FIHURE 404.2.4.1
 (H) LATCH APPROACH, PULL SIDE.
  
 4D) THE DETAIL # 1 SHOWS A 2X4 TO BE USED AS A
 HANDRAIL, PLEASE SHOW COMPLIANCE WITH 2010 FBC-B 1012.3
 HANDRAIL GRASPABILITY TYPE I OR TYPE II.
  
 4E) SHEET S1 DETAIL # 3 SHOWS STAIRS WITH A HANDRAIL
 THIS IS TO BE AN ACCESSIBLE STAIR IN COMPLIANCE WITH
 2010 FBC- 1012.6 HANDRAIL EXTENSIONS.
 HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING
 SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN
 ADJACENT STAIR FLIGHT OR RAMP RUN. WHERE HANDRAILS ARE
 NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL
 EXTEND HORIZONTALLY AT LEAST 12 INCHES (305 MM) BEYOND
 THE TOP RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF
 ONE TREAD BEYOND THE BOTTOM RISER. AT RAMPS WHERE
 HANDRAILS ARE NOT CONTINUOUS BETWEEN RUNS, THE
 HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING
 12 INCHES (305 MM) MINIMUM BEYOND THE TOP AND BOTTOM OF
 RAMP RUNS. THE EXTENSIONS OF HANDRAILS SHALL BE IN THE
 SAME DIRECTION OF THE STAIR FLIGHTS AT STAIRWAYS AND
 THE RAMP RUNS AT RAMPS.
  
 4F) NOTE # 3 INDICATES THE LIVE LOADS AT 60 PSF, PLEASE
 REVIEW THE 2010 FBC-B TABLE 1607.1(35) STAIRS 100 PSF
 STAIRS AND EXITS.
  
 5) NEW COMMENT SHEET S1:
  
 5A) THE STAIRS SHOW A VERTICAL RISE OF 7 1/8 INCHES.
 PLEASE REFER TO SECTION 2010 FBC-B 1009.4.2 STAIR RISER
 HEIGHTS SHALL BE 7 INCHES (178 MM) MAXIMUM AND 4 INCHES
 (102 MM) MINIMUM.
  
 5B) WITH THE FLOOR PLAN SHOWING 4 RISERS @ 7 1/8 IN. =
 28 1/2 INCHES. PLEASE NOTE IF THE TOP LANDING IS AT 28
 1/2 INCHES ABOVE GRADE THE RAMP SHOULD BE 28 + FEET
 LONG OR PROVIDE THE ELEVATION DIFFERENCE IN GRADE FOR
 THE ACCESSIBLE PARKING, THE BOTTOM LANDING TOP LANDING
 AND THE BOTTOM OF THE STAIRS.
 FBC-B 1010.2 SLOPE.
 RAMPS USED AS PART OF A MEANS OF EGRESS SHALL HAVE A
 RUNNING SLOPE NOT STEEPER THAN ONE UNIT VERTICAL IN 12
 UNITS HORIZONTAL (8.333-PERCENT SLOPE). THE SLOPE OF
 OTHER PEDESTRIAN RAMPS SHALL NOT BE STEEPER THAN ONE
 UNIT VERTICAL IN EIGHT UNITS HORIZONTAL (12.5-PERCENT
 SLOPE).
  
 5C) THE RAMP CROSS SECTION NOR DOES THE STAIR ELEVATION
 PROVIDE THE HEIGHT OF THE HANDRAIL PER:
 2010 FBC-B HANDRAIL HEIGHT, MEASURED ABOVE STAIR TREAD
 NOSINGS, OR FINISH SURFACE OF RAMP SLOPE, SHALL BE
 UNIFORM, NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE
 THAN 38 INCHES (965 MM).
  
 5D) NOTE ONLY NO ACTION REQUIRED!!!! THE PLANS DO NOT
 INDICATE THE MODULAR BUILDING BEING SET 30 INCHES ABOVE
 GRADE, NOTE IF SO FBC-B SECTION 1013.1-3 WILL BE
 REQUIRED.
  
 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
 4B)
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-01-27 Cont ID  
Sent By skennedy Date 2015-01-27 Time 13:13 Rev Time  
Received By skennedy Date 2015-01-08 Time   Sent To  
Notes
2015-01-09 08:07:51INCOMING SENT TO C-12.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2015-03-03 Cont ID  
Sent By jwitmer Date 2015-03-03 Time 14:37 Rev Time 0.00
Received By jwitmer Date 2015-03-03 Time 14:37 Sent To  
Notes
2015-03-03 14:37:56TO BE USED AS A CONSTRUCTION OFFICE ONLY, NOT A SALES
 OFFICE, NO IMPACT FEES WERE COLLECTED!!!!! JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-01-26 Cont ID  
Sent By jwitmer Date 2015-01-26 Time 07:14 Rev Time 0.00
Received By jwitmer Date 2015-01-26 Time 07:14 Sent To  
Notes
2015-01-26 07:14:45BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2015-03-03 Cont ID  
Sent By tklarge Date 2015-03-03 Time 14:49 Rev Time 0.00
Received By tklarge Date 2015-03-03 Time 14:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-02-28 Cont ID  
Sent By tklarge Date 2015-02-28 Time 07:05 Rev Time 0.00
Received By tklarge Date 2015-02-28 Time 06:10 Sent To  
Notes
2015-02-28 06:24:171)SHT. SCP.1 SHOWS THE WATER SERVICE TO THE SALES
 TRAILER AS 5/8". THE MINIMUM SIZE WATER SERVICE SHALL
 BE 3/4' PER THE 2010 FPC SEC.603.1
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-01-17 Cont ID  
Sent By tklarge Date 2015-01-17 Time 12:02 Rev Time 0.00
Received By tklarge Date 2015-01-17 Time 11:35 Sent To  
Notes
2015-01-17 12:01:581) A DRINKING FOUNTAIN IS REQUIRED PER TABLE 403.1 OF
 THE 2010 FL. PLUMBING CODE.
 2) A MINIMUM OF TWO DRINKING FOUNTAINS SHALL BE
 PROVIDED PER THE 2010 FL. ACCESSIBILITY CODE SEC.
 211.2.
 3) A BACKFLOW PREVENTION DEVICE SHALL BE INSTALLED ON
 THE WATER SERVICE TO THE UNIT. A MINIMUM OF A DOUBLE
 CHECK VALVE ASSEMBLY SHALL BE REQUIRED PER THE CITY OF
 WPB CROSS CONNECTION MANUAL.
 4) INDICATE ON THE PLANS IF THE UNIT IS GOING TO HAVE A
 SANITARY SEWER CONNECTION OR CONNECTED TO A HOLDING
 TANK. IF CONNECTED TO A HOLDING TANK INDICATE THE SIZE
 OF THE TANK ON THE PLANS. A PERMIT FROM THE PALM BEACH
 COUNTY HEALTH DEPARTMENT MAY BE REQUIRED.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2015-02-17 Cont ID  
Sent By llouie Date 2015-03-03 Time 10:51 Rev Time 0.00
Received By llouie Date 2015-02-12 Time 10:07 Sent To  
Notes
2015-02-17 10:52:14** ZONING APPROVED WITH THE FOLLOWING PROVISO **
  
 1.) WHEEL STOPS SHALL BE PROVIDED IN ALL PARKING
 STALLS.
  
 NOTES:
  
 - THIS PERMIT REVIEW IS FOR THE SALES TRAILER ONLY. ALL
 MODEL AND SPEC HOMES ARE NOT INCLUDED IN THIS REVIEW,
 AS PERMITS FOR THE MODEL AND SPEC HOMES CANNOT BE
 SUBMITTED PRIOR TO THE APPROVAL OF THE REPLAT.
  
 - SEPARATE PERMIT SUBMITTALS AND REVIEW REQUIRED FOR
 LANDSCAPING AND AWNING/SIGNAGE

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By llouie Date 2015-01-20 Time   Rev Time 0.00
Received By llouie Date 2015-01-20 Time 09:34 Sent To  
Notes
2015-01-20 12:57:51** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) PROVIDE A PARKING TABULAR TO ILLUSTRATE THE
 REQUIRED AND PROVIDED PARKING COUNT FOR THE SALES
 TRAILER. [ZLDR S.94-273(D)(73)(B)(6)]
  
 2.) WILL THERE BE SIGNAGE ON THE PROPOSED SALES
 TRAILER? IF SO, SIGNAGE REQUIREMENTS MUST COMPLY WITH
 THE REQUIREMENTS OF S.94-273(D)(73)(B)(7) OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS (ZLDR). A SEPARATE
 PERMIT AND REVIEW IS REQUIRED FOR SIGNAGE.
  
 3.) A BUFFER OF AT LEAST 20 FT. WIDE SHALL BE
 LANDSCAPED AND MAINTAINED BETWEEN ANY MODEL DWELLING
 UNIT, TEMPORARY SALES OFFICE OR PARKING AREA AND ANY
 ADJACENT LAND NOT IN THE DEVELOPMENT THAT IS ZONED FOR
 RESIDENTIAL PURPOSES. A SEPARATE LANDSCAPE PERMIT AND
 REVIEW SHOWING COMPLIANCE WITH THIS ZLDR REQUIREMENT
 SHALL BE SUBMITTED. [ZLDR S.94-273(D)(73)(B)(8)]
  
 4.) SHOW SETBACK DIMENSIONS FROM PROPERTY LINES.
 SETBACKS SHALL COMPLY WITH THE MINIMUM DIMENSIONS
 PROVIDED IN S.94-304(B)(2) OF THE ZLDR.
  
 5.) PROVIDE DIMENSION FOR THE HEIGHT OF THE TRAILER.
 THE HEIGHT SHALL NOT EXCEED 25 FT. [ZLDR
 S.94-304(B)(4)]
  
 6.) PROVIDE A PARKING LOT STRIPING DETAIL IN COMPLIANCE
 WITH THE REQUIREMENTS OF S.94-485(J) OF THE ZLDR.
  
 7.) TERMINAL LANDSCAPE ISLANDS SHALL BE A MINIMUM OF 5
 FT. IN WIDTH AND NOT LESS THAN THE LENGTH OF THE
 ADJACENT STALL. [ZLDR S.94-443(C)(3)(A)]
  
 8.) AT LEAST 30 PERCENT OF THE LINEAR FEET AROUND THE
 TRAILER SHALL BE PLANTED WITH LANDSCAPING. [ZLDR
 S.94-443(E)(1)]
  
 9.) ALL NEW PLANT MATERIAL SHALL MEET THE MINIMUM
 PLANTING SPECIFICATIONS IN S.94-445 OF THE ZLDR.
  
 10.) SHOW LANDING IN THE SITE PLAN.
  
 11.) THE TARA COVE PROJECT HAS BEEN ASSIGNED AN ADDRESS
 OF 4650 TARA COVE WAY. PLEASE CORRECT.
  
 12.) THIS PERMIT REVIEW IS FOR THE SALES TRAILER ONLY.
 ALL MODEL AND SPEC HOMES ARE NOT INCLUDED IN THIS
 REVIEW, AS PERMITS FOR THE MODEL AND SPEC HOMES CANNOT
 BE SUBMITTED PRIOR TO THE APPROVAL OF THE RE-PLAT.
  
 PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS
 MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE
 @ (561) 822-1458 IF YOU HAVE QUESTIONS.